Example: tourism industry

2300 Series Vibration Monitors Datasheet - 105M0340

DescriptionThe 2300 Vibration Monitors provide cost-effective continuous Vibration monitoring and protection capabilities for less critical and spared machinery. They are specifically designed to continuously monitor and protect essential medium to low criticality machinery in a wide range of industries including: oil & gas, power generation, water treatment, pulp and paper, manufacturing, mining, cement, and other 2300 Vibration Monitors deliver Vibration monitoring and high Vibration level alarming. They include two channels of seismic or proximity measurement inputs from various accelerometer, Velomitor and Proximitor types, a speed input channel for time-synchronous measurements, and outputs for relay contacts. The 2300/20 monitor features a configurable 4-20 mA output which interfaces more points to a DCS.

EN60079-15: 2010 EN60079-7: 2015 ATEX Directive 2014/34/EU RoHS RoHS Directive 2011/65/EU Hazardous Area Approvals For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from Bently.com. CSA/NRTL/C Class I, Division 2/ Zone 2 AEx nA nC [ic] IIC T4 Gc

Tags:

  Datasheet, Series, 2003, Monitor, Vibration, En60079, 2300 series vibration monitors datasheet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2300 Series Vibration Monitors Datasheet - 105M0340

1 DescriptionThe 2300 Vibration Monitors provide cost-effective continuous Vibration monitoring and protection capabilities for less critical and spared machinery. They are specifically designed to continuously monitor and protect essential medium to low criticality machinery in a wide range of industries including: oil & gas, power generation, water treatment, pulp and paper, manufacturing, mining, cement, and other 2300 Vibration Monitors deliver Vibration monitoring and high Vibration level alarming. They include two channels of seismic or proximity measurement inputs from various accelerometer, Velomitor and Proximitor types, a speed input channel for time-synchronous measurements, and outputs for relay contacts. The 2300/20 monitor features a configurable 4-20 mA output which interfaces more points to a DCS.

2 The 2300/25 monitor features System 1connectivity for Trendmaster SPA interface which enables users to leverage existing DSM SPA 2300 Vibration Monitors are designed for use on a broad range of machine trains or individual casings where the sensor point count fits the monitor s channel count and where advanced signal processing is desired. 2300/20and2300 Key Features2300/20 lTwo 4-20 mA outputs with internal current loop power supply. lContinuous monitoring and protection lTwo acceleration/velocity/proximity inputs with synchronized sampling for advanced diagnostics. lOne dedicated speed channel supporting Proximity probes, Magnetic pickup and Proximity switch type sensors. lSupports process variable on all three input channels. lKey measurements (Acceleration pk, Acceleration rms, Acceleration pk/rms, Velocity pk, Velocity rms, Displacement pp, Displacement rms, Speed) real-time provided with alarm configuration.

3 LEach channel has one measurement group and two bandpass measurements. lLCD and LED for real time value and status display. lEthernet 10/100 Base-T communication for configuration using Bently Nevada monitor Configuration software (Included) with RSA encryption. lLocal contacts for positive engagement of channel bypass, configuration lockout, and reset. lTwo relay outputs with programmable setpoints. lThree buffered transducer outputs (including Keyphasor signal) providing short circuit and EMI protection. Buffered outputs for each signal are through BNC connectors. lModbus over Ethernet. lAlarm Data CaptureCaution: Two 4-20 mA outputs will NOT work with an external powered loop. 2300/25 lTrendmaster SPA interface. lContinuous monitoring and protection. lTwo Acceleration/Velocity/Proximity inputs with synchronized sampling for advanced diagnostics.

4 LOne dedicated speed channel supporting Proximity probes, Magnetic pickup and Proixmity switch type sensor. lSupport process variable on all three input channels. lKey measurements (Acceleration pk, Acceleration rms, Acceleration pk/rms, Velocity pk, Velocity rms, Displacement pp, Displacement rms, Speed) real-time provided with alarm configuration. lEach channel has one measurement group and two bandpass measurements. lLCD and LED for real time value and status display. lEthernet 10/100 Base-T communication for configuration using Bently Nevada monitor Configuration software (included) with RSA encryption. lLocal contacts for positive engagement of channel bypass, configuration lockout, and reset. lTwo relay outputs with programmable setpoints. lThree buffered transducer outputs (including Keyphasor signal) providing short circuit and EMI protection.

5 Buffered outputs for each signal are through BNC connectors. lModbus over InputDC Input18~36 Vdc, max W Channel TypesICP AccelerometersConfigurable Bandpass Hz to 20 kHzScale Factor range5 to 1000 mV/gFull scale range2 to 80 g peakCurrent Sink Source mA 5%Open Circuit Voltage-21 to -24 Vdc VelocityConfigurable Bandpass filter Hz to 20 kHz Scale Factor range5 to 1000 mV/in/s Full scale range 0 to 50 in/s peak Radial VibrationConfigurable Bandpass filter Hz to 20 kHz Scale Factor range5 to 1000 mV/milFull scale range 0 to 160 mil peak-peakThrust ChannelScale Factor range5 to 1000 mV/milProcess Variable ChannelSupport most of unit with default on Channel TypesTemperatureChannel Hardware SpecificationConfigurable Upper OK limit to -22 V (greater than lowerOK)

6 Configurable Lower OK limit to -22 V (less than upperOK) Accuracy: 1% of full scale rangeIndependent 24-bit ADCs on input channelsSupports Bently transducer or 2/3 wires custom transducer for Accelerometers, Velomitor and transducers support multiple events per revolution and event ratios for speed inputs up to 20 voltage Vdc InterfacesProximity Transducer InterfaceSupply to VdcMaximum Rated Current15 mAShort Circuit Current mA to mAAccuracy 1% of full scale rangeInput Impedance 3-wire Voltage Mode, 10 k RPM range 6 to 120,000 Proximity Switch InterfaceSupply Voltage-10 to -24 VdcLower Not Ok VRpm range 6 to 60,000 3/242300/20and2300 InputsMagnetic Pick upInput voltageAdapt to sensor 284947 outputRPM range200 to 120,000 Contact InputsMonitor provides 3 contact capabilities with input terminalsConfiguration lockLatched alarm/relay reset functionMonitor Alarm/Relay InhibitActivate0 to 10 k De-activate 150 k to infiniteButton InputsExternal button to reset latched alarm and relayOne buried button provides 3 functions lDisplay monitor information lLCD contrast adjustment lReset settings to default Display monitor InformationReset listed settings to Default lUser account name lIP Address lFW/HW versionJumper Between COM & Chassis GNDJ umpers are 2-pin terminal interfaces that connects COM to the Chassis ground (GND).

7 Alternatively, COM can be connected to an earth ground separately through a OutputThree buffered outputs are available on the monitor through BNC connectors2 Vibration Outputs 1 Speed OutputRelaysRelays provide two dry-contact outputsMay be normally energized or de-energizedNo output feedback determination Relay Circuit Specification inNon-Hazardous AreaType Single pole, double throw SealingEpoxy sealed Contact life100,000 cycles @ 5 amps 250 Vac 200,000 @ 1 amp, 24 VdcInsulationresistance 1000 M minimum @ 500 VdcRelay closed contact resistance1 maximumRelay open contact resistance 1 M minimumMaximum switched contact voltage 250 Vac / 250 VdcMaximum breaking contact current 6 A @250 Vac / 6 A @24 VdcMaximum switched 1500VA AC / 150 Watts 4/242300/20and2300 Circuit Specification inNon-Hazardous Areapower DC Relay Circuit Specification inHazardous AreaMaximum switched contact voltage and current6 A @24 Vac / 5 A @ 30 Vac / A @24 Vdc / 4 A @30 Vdc4-20mA Output (2300/20)Two 4-20 mA outputs with internal current loop power supply4 to 20 mA output values are proportional to the full-scale of the associated configuration may determine the variable of each output.

8 Voltage compliance: 0 to +12 Vdc range across resistance: 0 to 600 Resolution: AAccuracy: 1% over operating temperature rangeUpdate rate: 100 msConfigurable with default 2 mA clamp currentNo output feedback determinationCaution: Two 4-20 mA outputs will NOT work with an external powered Output (2300/25)Input signal rangeHigh AC: 8 Vpp Low AC: Vpp DC GAP: 0 to -20 Vdc (max measurable AC signal is 1 Vpp).AccuracyHigh/Low AC: 1% of Full-Scale at 100 Hz DC GAP: V (measurable AC accuracy: Relay Circuit Specification inHazardous Area 20 mV)Frequency response10 Hz to 3000 Hz 5%LEDsOKIndicates when the monitor is operating faultIndicates hardware fault that is impacting alarm inhibitIndicates the alarm/relays have been intentionally inhibited from user initiated bypass statusIndicates if relays have been the Ethernet status and monitor communicating with remote channel statusIndicates the speed channel has valid speed signal input OR operating correctly when Alarm StatusAlert LEDE ngages if any channel is in alert LEDE ngages if any channel is in danger state.

9 LCD DisplayAllows viewing machine speed, Vibration measurements value, setpoints, and configuration EthernetEthernet, 10 Base-T and 100 Base-TX. Conforms to RJ-45 for 10 Base-T/100 Base-TX Ethernet cabling Cable length: 100 meters (328 ft.) maximum Environmental Limits Operating Temperature-30 C to +65 C (-22 F to +149 F)Storage Temperature-40 C to +85 C (-40 F to +185 F)HumidityUp to 95%, non-condensingVibration Limitation3 gBattery Life for Real Time ClockPowered: 38 years @ 50 C (122 F) Un-powered: 12 years @ 50 C (122 F) Physical Dimensions (Width x Depth x Height) 127 mm x 127 mm x mm (5 in. x 5 in. x 3 in.) kg ( lbs) MountingPanel mount or DIN rail (adapter included)System 1 Evolution Connectivity2300 Monitors connect to System 1 Evolution and support current value and time-based data collection of all static values, waveforms, and spectral data.

10 This includes System1 Software's full suite of plots and tools for condition monitoring and asset and event is triggered on the 2300 monitor , the following high-resolution alarm data is forwarded to System Measurements: DurationIntervalsPre-Event Data10 minutes1 second20 seconds100 millisecondsPost-Event Data10 seconds100 milliseconds1 minute1 secondSpectrums/Waveforms: DurationIntervalsPre-Event minutes10 secondsPost-Event Data1 minute10 secondsIn the event of a network disruption between the 2300 and System 1, the 2300 can store up to at least 5 alarm data captures. (This requires System 1 Evolution or newer and Firmware release or newer for 2300.)6/242300/20and2300 and CertificationsFCCThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: lThis device may not cause harmful interference.