3 port solenoid valve rubber seal Series SYJ300/500/700. SY. SYJ. Low power consumption: (Without light) VK. (Current draw: 21mA at 24V DC). VZ. Completely interchangeable VT. Pilot exhaust with the previous VT. Series VJ300/500/700 and VZ300/500. Mounts on the same subplates and manifolds as VP. the VJ300/500/700 and the VZ300/500. VG. Series VJ Series VZ. SYJ300 VJ300 . SYJ500 VJ500 VZ300. SYJ700 VJ700 VZ500. VQ. VQZ. Standard Valve suitable for copper free applications Valve can be piped for selector Vacuum applicable or divider applications.

2.2-2 Series SYJ300/500/700 SYJ300 SYJ500 SYJ700 SYJ300 SYJ500 SYJ700 M3 M5 1/8 M5 1/8 N.C. N.O. 3 Port Solenoid Valve Rubber Seal Variations Series

Tags:

  Series, Seal, Valves, Rubber, Solenoid, Ports, 3 port solenoid valve rubber seal series, 3 port solenoid valve rubber seal

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 3 Port Solenoid Valve Rubber Seal Series …

1 3 port solenoid valve rubber seal Series SYJ300/500/700. SY. SYJ. Low power consumption: (Without light) VK. (Current draw: 21mA at 24V DC). VZ. Completely interchangeable VT. Pilot exhaust with the previous VT. Series VJ300/500/700 and VZ300/500. Mounts on the same subplates and manifolds as VP. the VJ300/500/700 and the VZ300/500. VG. Series VJ Series VZ. SYJ300 VJ300 . SYJ500 VJ500 VZ300. SYJ700 VJ700 VZ500. VQ. VQZ. Standard Valve suitable for copper free applications Valve can be piped for selector Vacuum applicable or divider applications.

2 Bright colour tone and Up to -100kPa Universal porting is possible. state of the art design Application Example qBlow off Valve wValve for vacuum eOperation of a single rDivider Valve tSelector Valve yPressure release Valve 3 3 3 3. (SYJ 5 R) control acting cylinder (SYJ 5 R) (SYJ 5 R) (SYJ 5 R). 7 3 3 3 7 7 7. (SYJ R). 5 (SYJ /SYJ R). 5 5. 7 7 7. X port X port X port X port X port Tank (R)3 (R)3 2(A) 2(A) 2(A). 2(A) 2(A) (R)3 2(A) (R)3. (R)3 (R)3. (P)1. Tank (P)1 Plug (P)1 (P)1 (P)1 (P)1. 3 port solenoid valve rubber seal Series SYJ300/500/700.

3 Variations Option Effective area Voltage Manual Series Port size (mm2) Actuation Electrical entry override (Nl/min) Indicator light and surge voltage suppressor SYJ300. M3 ( ). Grommet SYJ500. Body ported M5 ( ) L plug connector SYJ700. 1/8 ( ). DC M plug DC Non-locking connector With surge voltage push style 24V DC suppressor 12V DC. 6V DC With indicator light SYJ300 5V DC. 3V DC. and surge voltage suppressor Push-locking slotted style M5 ( ). Base mounted SYJ500. 1/8 ( ). SYJ700. 1. 8 /1 4 ( ). Series SYJ300/500/700.

4 Manifold Variations A port size A Port P/R port With built-in One-touch fitting Valve Series location size M3 M5 Applicable tube 1/8 4 6 8. (1). M5 . SYJ300 Top Body ported (2). 1/8 SY. SYJ500 Top 1/8 SYJ. (1). VK. 1/8 . SYJ700 Top 1/4 . VZ. M5. (1). VT. SYJ300 Side Base mounted 1/8 VT. Bottom . SYJ500 1/8 VP. Side . 1/8 (1) VG. Bottom SYJ700 1/4 . Side 1/4 . Note 1) Only internal pilot style Note 2) Only external pilot style VQ. VQZ. Series SYJ300 Series SYJ500 Series SYJ700. Series SYJ300/500/700.

5 Precautions Be sure to read before handling. Refer to to 0-36 for Safety Instructions and common precautions on the products mentioned in this catalog. Cover Warning Cover Groove Pin Operation of Manual Override Groove Lever Pin DC indicator Use caution since manual override operation will operate Socket DXT170-71-1. any connected actuators. Non-locking push style [Standard] Connector housing Press in the direction of the arrow. Hook Lead wire wCrimping connection of lead wire and socket Strip to of the lead wire ends, insert each stripped wire into a socket and crimp it using special crimping tool.

6 Be careful that the Push-locking slotted style [D] outer insulation of the lead wires does not interfere with the socket While pressing, turn in the direction of the arrow. contact part. If you do not turn, the mechanism does not lock in position. (Contact SMC for the special crimping tool.). Locked position Core wire contact area Crimping area Core wire PUSH LOCK. Socket Lead wire to Max. cover diameter: Hook Insulation Note) A second manual override is located on the pilot Valve assembly . eConnection/Disconnection of socket with lead wire It is only available as a non-locking push style.

7 Simply depress in the direction of the arrow shown to operate. Connection Insert lead wire and crimped socket into square holes (indicated as positive or negative) of connector. Press the socket in fully until the hook of the socket locks into the Caution groove of the connector housing. Confirm the locked position by lightly pulling on the lead wire. Common Exhaust Port for The Pilot and Main Valve Disconnection Pilot air is exhausted through the main Valve body rather To remove the socket from the connector, pull out lead wire than directly to atmosphere.

8 While depressing the hook of the socket with a fine screw Suitable for applications where exhausting the pilot Valve driver (or similar). If the socket is to be re-used, reposition to atmosphere would be detrimental to the surrounding the hook again. working environment. Connector housing For use in extremely dirty environments where there is the Socket possibility that dust could enter the pilot exhaust and damage the Valve . Ensure that the piping of exhaust air is not too restrictive. Lead wire Hook Caution Caution Bracket Plug Connector Lead Wire Length When with bracket of SYJ300, do not use it without a Standard length is 300mm, but the following lengths are bracket.

9 Also available. Caution How to Order Connector Assembly How to Use Plug Connector For DC: SY100 30 4A. qConnection/Disconnection of connector Without lead wire Connection Push the connector straight on to the pins (with connector and : SY100 30 A Lead wire length (mm). of the Solenoid , making sure the lip of the lever securely 2 sockets.) 300. "locks" into the groove of the Solenoid cover. How to Order 6 600. Disconnection Press the lever against the connector To order a Valve with lead wire length of other 10 1000.

10 Housing and pull it outward from the Solenoid than 300mm, indicate part numbers. of the Valve 15 1500. without connector and the required connector 20 2000. assembly separately. 25 2500. (Example) 2000mm lead wire length 30 3000. For DC 50 5000. SYJ312-5LO-M3. SY100-30-4A-20. Series SYJ300/500/700. Caution Connector Assembly with Protective Cover Surge Voltage Suppressor Connector assembly with protective cover enhances dust protection. <For DC>. Grommet, L and M plug connector Effective in preventing possible short circuit problems due to contaminants in contact with connector section.