300 W 320 W Poly-crystalline Solar ModuleSEP 300W/305W/310W/315W/320W Plus power tolerance to +3% to ensure the high reliability of power output PV glass design improves oblique irradiance performance and enhances Module yield in low-light and medium-angle-light condition Junction box and by-pass diodes guarantee the modules free of overheating and hot spot effect 100% EL test before and after lamination, providing higher quality assurance Easy installation and minimal maintenance with compatibility to industry standard inverters and mounting systems Modules certified by T V to withstand high level of wind and snow loads (2400 Pa / 5400 Pa), hailstone impact (25 mm at 23 m/s), atmospheric impact (Salt-mist corrosion Test, Ammonia Resistance Test), potential induced degradation (PID) test and Carbon footprint assessment Special PV Module Insurances by world leading insurance company guarantees the benefit to PV investors and PV Module usersCertificatesWarranty10 Years: Manufacturing Warranty 12 Years Warranty: 90% Power Output 25 Years Warranty: 80% Power OutputSolar cell type Poly-crystalline 156 156 mmDimensions 1956 992 50 mmWeight kgGlass Anti-reflective coated, high transmission, low iron, temperedGlass thickness mmEncapsulation EVA (ethylene vinyl acetate)Back side WhiteFrame Anodized aluminum alloyNo of draining holes in frame 16 Type of connector MC4 compatibleJunctio

All techn ical d ata tsta ndrd test ond ition AM =1.5 E= 100W /m2 Tc25 PV-JB003 1000v DC IP65 4mm2 TUV 992ˇ1 942 1956

Tags:

  Module, Solar, Poly, Stats, Crystalline, 320 w poly crystalline solar module

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 300 W – 320 W Poly-crystalline Solar Module - Sunceco

1 300 W 320 W Poly-crystalline Solar ModuleSEP 300W/305W/310W/315W/320W Plus power tolerance to +3% to ensure the high reliability of power output PV glass design improves oblique irradiance performance and enhances Module yield in low-light and medium-angle-light condition Junction box and by-pass diodes guarantee the modules free of overheating and hot spot effect 100% EL test before and after lamination, providing higher quality assurance Easy installation and minimal maintenance with compatibility to industry standard inverters and mounting systems Modules certified by T V to withstand high level of wind and snow loads (2400 Pa / 5400 Pa), hailstone impact (25 mm at 23 m/s), atmospheric impact (Salt-mist corrosion Test, Ammonia Resistance Test), potential induced degradation (PID) test and Carbon footprint assessment Special PV Module Insurances by world leading insurance company guarantees the benefit to PV investors and PV Module usersCertificatesWarranty10 Years: Manufacturing Warranty 12 Years Warranty: 90% Power Output 25 Years Warranty: 80% Power OutputSolar cell type Poly-crystalline 156 156 mmDimensions 1956 992 50 mmWeight kgGlass Anti-reflective coated, high transmission, low iron, temperedGlass thickness mmEncapsulation EVA (ethylene vinyl acetate)Back side WhiteFrame Anodized aluminum alloyNo of draining holes in frame 16 Type of connector MC4 compatibleJunction box (Protection degree) IP 67 Cable type (Cross-sectional area / length) 4 mm2 / 900 5 mmTechnical DrawingsSOLAR CELLS Poly-crystalline 156 156 MM 72 PCS.

2 (6 12) 4 BUS BARSM aximum Power (Pmax) 300 Wp305 Wp310 Wp315 Wp320 WpVoltage at Pmax (Vmp) VCurrent at Pmax (Imp) AOpen-Circuit Voltage (Voc) VShort-Circuit Current (Isc) AMaximum System Voltage (V DC) 1000 V (iec), 600 V (UL)Cell Efficiency % % % % % Module Efficiency % % % % %Number of By-pass Diodes 6 Maximum Series Fuse 15 ATemperature Coefficient of Pmax - % / CTemperature Coefficient of Voc - % / CTemperature Coefficient of Isc - % / CNominal Operating Cell Temperature 47 2 CElectrical CharacteristicsCells temp. = 25 C108642001020304050 Voltage [V]Current [A]Incident Irrad. = 1000 W/m2 Incident Irrad. = 800 W/m2 Incident Irrad. = 600 W/m2 Incident Irrad. = 400 W/m2 Incident Irrad. = 200 W128642001020304050 Voltage [V]Current [A]Cells temp. = 10 C, Pmpp = WCells temp. = 25 C, Pmpp = WCells temp. = 40 C, Pmpp = WCells temp. = 55 C, Pmpp = WCells temp. = 70 C, Pmpp = WIncident irradiation = 1000 W/m2 Test ParametersDielectric Insulation Voltage 6,000 V DC maxOperating Temperature -40 C to 85 CI-V Curves at different irradianceI-V Curves at different temperatureSunceco, Inc.

3 | | email: NumberRat ed Maximum P owerOut put T ol eranceCurrent a t P maxVoltage at P maxShort-Circui t C urrentOpen-Circuit Volt ageNominal O perating C el l T emp(Pmax)(Imp)(Vmp)(Isc)(Voc)Wei ghtDomensionMaximum System V oltageMaxmum series F us e Rati ngCell TechnologyApplication Class AAll technical data at st andard test conditionAM= DCIP65 4mm2 TUV992 19421956 111561656156992 11956 1156321491270707022A-A1150352 FRONT VIEWBACK VIEWD rainage holes8-9 14 Mounting slots2- 4 Ground holes3550