Repair and Parts Visit our website;. 312667L. X5 . , X7 . , ProX7 & ProX9 Airless sprayers EN. - For portable spray applications of architectural paints and coatings. For professional use only- Models 262800, 262805, 261815, 261820. See page 3 for model and series information including dispense rate, recommended hose length, guns, and maximum working pressure. X5 and X7 Models ONLY: Use water based or mineral-spirit type material only. Do not use IMPORTANT SAFETY INSTRUCTIONS. materials having flash points lower than 70 F (21 C). Read all warnings and instructions in this manual. This includes, but is not limited to, acetone, xylene, Save these instructions.

3. Grasp cart handle securely with one hand. With the other hand, lift and pull handle (a) located in front of sprayer frame, toward you. Lift up front of sprayer until you hear a click and the cart is locked in place. 4. Install hose rack (d) to frame handle. Install lock nuts. Tighten securely. 5. Secure power cord in clip (e) located underneath

Tags:

  Sprayers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 312667L, X5, X7, ProX7 and ProX9 Airless Sprayer, Repair ...

1 Repair and Parts Visit our website;. 312667L. X5 . , X7 . , ProX7 & ProX9 Airless sprayers EN. - For portable spray applications of architectural paints and coatings. For professional use only- Models 262800, 262805, 261815, 261820. See page 3 for model and series information including dispense rate, recommended hose length, guns, and maximum working pressure. X5 and X7 Models ONLY: Use water based or mineral-spirit type material only. Do not use IMPORTANT SAFETY INSTRUCTIONS. materials having flash points lower than 70 F (21 C). Read all warnings and instructions in this manual. This includes, but is not limited to, acetone, xylene, Save these instructions.

2 Toluene, or naptha. For more information about your Related Manual material request MSDS from distributor or retailer. 312001. MAGNUM X5 MAGNUM ProX7 MAGNUM ProX9 . Model: 262800 Model: 261815 Model: 261820. Series A, B, C, D Series A Series A. ti11304a ti9369a ti9368a MAGNUM X7. MAGNUM ProX7 MAGNUM ProX9 . Model: 262805. Model: 261815 Model: 261820. Series A, B, C. Series B Series B. ti11305a ti9369b ti16976a Table of Contents Table of Contents Specifications .. 3 Control Board Diagnostics (X5 and X7) .. 27. Getting Started Pump Diagnostics .. 27. Fold-n-Store Cart (ProX, Series A sprayers List of Kits (Series A) .. 28. Only) .. 3 List of Kits (Series B, C, D).

3 29. Warnings .. 4 Parts .. 30. Component Identification .. 8 X5 Model 262800 (Series A) .. 30. Installation .. 10 X5 Model 262800 (Series B, C, D) .. 33. Grounding and Electric Requirements .. 10 X7 Model 262805 (Series A) .. 36. Thermal Overload .. 10 X7 Model 262805 (Series A) .. 38. Operation .. 11 X7 Model 262805 (Series B, C) .. 39. Trigger Lock .. 11 X7 Model 262805 (Series B, C) .. 40. Pressure Relief Procedure .. 11 X7 Model 262805 (Series B, C) .. 41. Pressure Control Knob Settings .. 11 ProX7 and ProX9 Models 261815 and 261820. General Repair Information .. 12 (Series A, B) .. 42. Basic Troubleshooting .. 13 ProX7 and ProX9 Models 261815 and 261820.

4 Advanced Troubleshooting .. 18 (Series A) .. 44. General Problem: Motor Does Not Operate .. 18 ProX7 and ProX9 Models 261815 and 261820. General Problem: Circuit Breaker is Tripping .. 21 (Series B) .. 45. General Problem: Erratic Motor Operation .. 22 Wiring Diagrams .. 46. General Problem: Low or Fluctuating Output .. 23 X5 and X7 Models 262800 and 262805. (Series A) .. 46. General Problem: Excessive Pressure Build Up 24. ProX7 and ProX9 Models 261815 and 261820 . 48. Motor Diagnostics (X5 and X7) .. 25. Technical Data .. 49. Motor Diagnostics ( ProX7 and ProX9 ) .. 25. Notes .. 51. Pressure Control Switch Diagnostics .. 26. Graco Standard Warranty.

5 52. Control Board Diagnostics ( ProX7 and ProX9 ) . 27. 2 312667L. Specifications Specifications This equipment is not intended for use with flammable or combustible materials used in places such as cabinet shops or other factory , or fixed locations. If you intend to use this equipment in this type of application, you must comply with NFPA 33 and OSHA requirements for the use of flammable and combustible materials. Maximum Working Pressure Dispense Rate Hose Length and Gun Model Name Series gpm (lpm) Diameter Model PSI MPa bar gpm 1/4 in. x 25 ft MAGNUM X5 A, B, C SG2 2800 19 193. ( lpm) ( mm x m). gpm 1/4 in. x 25 ft MAGNUM X5 D SG2 3000 21 207.

6 ( lpm) ( mm x m). gpm 1/4 in. x 25 ft MAGNUM X7 A, B, C SG2 3000 21 207. ( lpm) ( mm x m). MAGNUM gpm 1/4 in. X 50 ft A, B SG3 3000 21 207. ProX7 ( lpm) ( mm x 15 m). MAGNUM gpm 1/4 in. X 50 ft A, B SG3 3000 21 207. ProX9 ( lpm) ( mm x 15 m). Getting Started Fold-n-Store Cart (ProX, Series A sprayers Only). 1. Unfold Fold-n-Store d a handle (a) and align 4. Install hose rack (d) to frame as shown. handle. Install lock nuts. Tighten securely. 2. Tighten wingnuts (b). b ti9675a 3. Grasp cart handle securely with one hand. ti9369a With the other hand, lift 5. Secure power cord in clip and pull handle (a) (e) located underneath located in front of storage compartment.

7 Sprayer frame, toward you. Lift up front of sprayer until you hear a click and the cart is locked in place. c ti9679a e ti9719a 312667L 3. Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and Repair of this equipment. The exclama tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. Refer back to these warnings. Additional, product specific warnings may be found throughout the body of this manual where applicable. WARNING. WARNING. GROUNDING. This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

8 This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper installation of the grounding plug is able to result in a risk of electric shock. When Repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.

9 Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qual ified electrician. This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illus trated in the figure below. ti9164a Only connect the product to an outlet having the same configuration as the plug. Do not use an adapter with this product. Extension Cords: Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that accepts the plug on the product. Make sure your extension cord is not damaged. If an extension cord is necessary, use 12 AWG. ( mm2) minimum to carry the current that the product draws.

10 An undersized cord results in a drop in line voltage and loss of power and overheating. 4 312667L. Warnings WARNING. WARNING. FIRE AND EXPLOSION HAZARD. Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment. For X5 and X7 models: only use water-based or min eral spirit-type materials with a flash point greater than 70 F (21 C). Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes.


Related search queries