Example: biology

5335D - PR electronics

2-wire transmitter with HART protocol5335 DRTD, TC, Ohm, or mV input Extremely high measurement accuracy HART 5 protocol Galvanic isolation For DIN form B sensor head mounting ApplicationsApplicationLinearized temperature measurement with , , or TC sensor. Difference or average temperature measurement of 2resistance or TC sensors. Conversion of linear resistance variation to a standard analogcurrent signal, for instance from valves or Ohmic levelsensors. Amplification of a bipolar mV signal to a standard mAcurrent signal. Connection of up to 15 transmitters to a digital 2-wire signalwith HART communication. Technical characteristicsWithin a few seconds the user can program PR5335D tomeasure temperatures within all ranges defined by the norms. The RTD and resistance inputs have cable compensation for2-, 3- and 4-wire connection. The 5335D has been designed according to strict safetyrequirements and is therefore suitable for application in SIL 2installations.

5335D-020618 Environmental Conditions Operating temperature.....-40°C to +85°C Calibration temperature..... 20...28°C

Tags:

  Temperatures, 5335d

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 5335D - PR electronics

1 2-wire transmitter with HART protocol5335 DRTD, TC, Ohm, or mV input Extremely high measurement accuracy HART 5 protocol Galvanic isolation For DIN form B sensor head mounting ApplicationsApplicationLinearized temperature measurement with , , or TC sensor. Difference or average temperature measurement of 2resistance or TC sensors. Conversion of linear resistance variation to a standard analogcurrent signal, for instance from valves or Ohmic levelsensors. Amplification of a bipolar mV signal to a standard mAcurrent signal. Connection of up to 15 transmitters to a digital 2-wire signalwith HART communication. Technical characteristicsWithin a few seconds the user can program PR5335D tomeasure temperatures within all ranges defined by the norms. The RTD and resistance inputs have cable compensation for2-, 3- and 4-wire connection. The 5335D has been designed according to strict safetyrequirements and is therefore suitable for application in SIL 2installations.

2 Continuous check of vital stored data for safety reasons. Sensor error detection according to the guidelines in NAMURNE89. Mounting / installationFor DIN form B sensor head mounting. This page is automatically generated on the basis of information provided on and affiliated websites. It is provided to you as a service and for informationpurpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability5335D-020618 Environmental ConditionsOperating C to +85 CCalibration CRelative < 95% RH (non-cond.)Protection degree ( )..IP68 / IP00 Mechanical 44 x mmWeight gWire x mm2 stranded wireScrew terminal 4 gCommon specificationsSupplySupply VDCI solation voltageIsolation voltage, test kVAC / 50 VACR esponse timeResponse time (programmable).

3 SWarm-up Link & HARTS ignal / noise 60 than of selectedrangeSignal dynamics, bitSignal dynamics, bitEffect of supply voltage < of span / VDCEMC immunity < of spanExtended EMC immunity: NAMURNE21, A criterion, < 1% of spanInput specificationsCommon input specificationsMax. of selected max. valueRTD inputRTD , Ni100, lin. RCable resistance per (up to 50 per wire ispossible with reducedmeasurement accuracy)Sensor mAEffect of sensor cable resistance(3-/4-wire)..< / Sensor error inputThermocouple , E, J, K, L, N, R, S, T, U,W3, W5 Cold junction compensation(CJC)..< CSensor error error current: Whendetecting / 33 A / 0 AVoltage inputMeasurement +800 mVMin. measurement range (span).. mVInput M Output specificationsCurrent outputSignal mAMin. signal mALoad (@ current output).. (Vsupply - 8) / [ ]Load of span / 100 Sensor error mANAMUR NE43 mA / mAof of the presently selectedrangeObserved authority 020/2011 ApprovalsATEX 2014/34 XEAC Ex TR-CU 012 f.

4 Certific. No. assessed for use inSIL applications


Related search queries