RedGard Waterproofing and Crack Prevention Membrane / TDS 1041 Product NameRedGard Waterproofing and Crack Prevention Membrane2 ManufacturerCustom Building ProductsTechnical Services10400 Pioneer Boulevard, Unit 3 Santa Fe Springs, CA 90670 Customer Support: 800-272-8786 Technical Services: 800-282-8786 Fax: 800- 200-7765 Email: DescriptionA ready-to-use elastomeric waterproofing membrane for bothcommercial and residential tile and stone application. Suited forinterior and exterior substrates, RedGard creates a continuouswaterproof membrane barrier with outstanding adhesion and reducescrack transmission in tile and stone floors. It bonds directly to cleanmetal drains, PVC, stainless steel and ABS drain assemblies and canbe used as a slab-on-grade moisture vapor barrier under all types offloor FeaturesReady to use - Roll it onQuick dry formulaListed with IAPMO for use as a shower pan linerSuitable SubstratesConcrete, cement mortar, masonryCement BackerboardExterior Plywood and OSB (interior, dry areas only)Exterior Decks - Contact Technical ServicesPost-Tensio

5HG*DUG :DWHUSURRILQJDQG&UDFN3UHYHQWLRQ0HPEUDQH 7'6 Drains should have a clamping ring with open weep holes for thin-set application. Apply the membrane to …

Tags:

  Nidra

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 5HG*DUG …

1 RedGard Waterproofing and Crack Prevention Membrane / TDS 1041 Product NameRedGard Waterproofing and Crack Prevention Membrane2 ManufacturerCustom Building ProductsTechnical Services10400 Pioneer Boulevard, Unit 3 Santa Fe Springs, CA 90670 Customer Support: 800-272-8786 Technical Services: 800-282-8786 Fax: 800- 200-7765 Email: DescriptionA ready-to-use elastomeric waterproofing membrane for bothcommercial and residential tile and stone application. Suited forinterior and exterior substrates, RedGard creates a continuouswaterproof membrane barrier with outstanding adhesion and reducescrack transmission in tile and stone floors. It bonds directly to cleanmetal drains, PVC, stainless steel and ABS drain assemblies and canbe used as a slab-on-grade moisture vapor barrier under all types offloor FeaturesReady to use - Roll it onQuick dry formulaListed with IAPMO for use as a shower pan linerSuitable SubstratesConcrete, cement mortar, masonryCement BackerboardExterior Plywood and OSB (interior, dry areas only)Exterior Decks - Contact Technical ServicesPost-Tension Concrete - Contact Technical ServicesLightweight Concrete (min.)

2 2000 psi compressive strength)Gypsum-Based cement topping (min. 2000 psi compressive strength)Existing ceramic tile and resilient flooringFloor heating systems - contact Technical ServicesComposition of ProductRedGard is a liquid-applied elastomeric waterproofing material thatcures to form a monolithic of Product in the InstallationEasy to use and can be applied by roller, trowel or airless sprayerRated for extra heavy duty serviceReduces curing time with quick-dry formulaIsolates cracks to 1/8" (3 mm)Suitable for waterproofing pools, spas and water featuresMeets Uniform Plumbing Code specifications for use as a shower panlinerLimitations to the ProductDo not apply to surfaces that may drop below 40 F (4 C) within 72hours of not apply over wet surfaces or surfaces subject to not use to bridge or cover over existing expansion, control,construction, cold or saw cut joints use Crack Buster Pro Membranefor control, cold or saw cut not use as an not use as a wear surface.

3 The membrane must be covered withtile or other permanent not use solvents in conjunction with the membranePackaging1 gallon ( L) gallon ( L) pail4 Technical DataApplicable StandardsAmerican National Standards Institute (ANSI) ANSI , , , and American National Standards for theInstallation of Ceramic Tile ASTM International (ASTM)ASTM C627 Standard Test Method for Evaluating Ceramic Floor TileInstallation Systems Using the Robinson-Type Floor TesterASTM D638 Standard Test Method for Tensile Properties of PlasticsTile Council of North America (TCNA) TCNA Handbook for Ceramic TileInstallation, TCNA Method EJ171, F125 & F125 AApprovalsRedGard has tested and complies with Uniform Plumbing Code andInternational Plumbing Code standards for use as a shower pan linerper IAPMO Research and Testing, Inc.

4 , File No. 4244. RedGard hastested and complies with International Building Code (IBC),International Residential Code (IRC) and International Plumbing Code(IPC) standards for water resistance per ICC Evaluation Service, ESR-1413. RedGard conforms to safing material requirementsestablished by the Wisconsin Administrative Code, Chapter Waterproofing and Crack Prevention MembranePublished Date: 3/29/2018 RedGard Waterproofing and Crack Prevention Membrane / TDS 104 Technical ChartPropertyTest MethodRequirementTypical GrowthPassSeam > 8 lbs/"width16 lbs/2" ( cm) > 170 psi484 psi (34kg/cm ) +/- WaterPenetrationPass at 25 milsdrySteam ShowerRequirementASTM E-96 Method E< permsat 30 mils dryShear Bond Strength to Cement MortarFour Week > 50 psi267 psi ( )Shear StrengthAfterWater > 50 psi89 psi ( kg/cm )System Crack > 1/16" and <1/8" Pass at 30 > 1/8" Pass at 30 milsdryPoint > 1000 lbs > 1000 psiRobinson Specified14 Cycles.

5 ExtraHeavyEnvironmental ConsiderationCustom Building Products is committed to environmentalresponsibility in both products produced and in manufacturingpractices. Use of this product may contribute to LEED Surface PrepUSE CHEMICAL-RESISTANT GLOVES, such as nitrile, whenhandling and wet areas must have proper sloping to drains. All surfacesmust be structurally sound, clean, dry and free from contaminants thatwould prevent a good bond. Newly prepared concrete must betroweled smooth and textured to a fine broom finish and cured for 28days. Existing surfaces must be scarified and leveled, and all defectsmust be repaired. Cracks exceeding 1/8" (3 mm) should be treated inaccordance with TCNA F125 or TCNA to Lightweight Cement and Gypsum SurfacesLightweight or gypsum-based materials must obtain a minimum of2000 psi ( MPa) compressive strength at the recommended curetime.

6 The underlayment must be sufficiently dry and properly cured tothe manufacturer's specifications for permanent, non-moisturepermeable coverings. Surfaces to be covered must be clean,structurally sound and subject to deflection not to exceed the currentANSI standards. Expansion joints must be installed in accordance withlocal building codes and ANSI/TCNA guidelines. Prime all surfaces toreceive RedGard with properly applied manufacturer's sealer or witha primer coat of RedGard , consisting of 1 part RedGard , dilutedwith 4 parts clean, cool water. In a clean pail, mix at low speed toobtain a lump-free solution. The primer can be brushed, rolled orsprayed to achieve an even coat. Apply the primer coat to the floor ata rate of 300 ft/gallon ( M/L) of reduced material.

7 When dry, applyat least one full coat of RedGard to the primed BarrierWhen used as a vapor barrier, apply one full coat (70 sq. ft. pergallon) where vapor transmission is up to 8 lbs. per 1000 sq. ft. perday and two full coats (70 sq. ft. per gallon each coat) wherevapor transmission is up to 12 lbs. per 1000 sq. ft. per day. Refer toASTM F1869 for more information on Vapor Transmission Joint PlacementDo not bridge joints designed to experience movement. Carry thesetypes of joints through the tile work. Clean the joint and install an openor closed cell-backer rod to the proper depth, as outlined in the TileCouncil Handbook, EJ171. Next compress sealant into the joint, coatingthe sides and leaving the sealant flush with the surface.

8 When thesealant is dry, place bond-breaker tape over the joint. Apply aminimum 3/64" ( mm) of RedGard over the joint and thesubstrate, following the instructions provided previously. Install the tilework onto the membrane, but do not bridge the joint. After the tilework is properly set, follow the architect's and manufacturer'sinstructions to fill the joint with a specified color of ProductSHOWER RECEPTORS INSTALLATIONM ortar Bed over Framed Structures B414 Cement Backerboard Walls B415 Surface Bonded Waterproofing B421 Download the illustrated installation details by clicking on the link aboveor go to , select Tile as theinstallation type and select the appropriate illustrated TCNA detail bynumber (example: B414).

9 RedGard at DrainsRedGard Waterproofing and Crack Prevention MembranePublished Date: 3/29/2018 RedGard Waterproofing and Crack Prevention Membrane / TDS 104 Drains should have a clamping ring with open weep holes for thin-setapplication. Apply the membrane to the bottom of the flange. Thedrain should be fully supported, without movement, and should beeven with the plane of the substrate. Apply the RedGard membranearound drain. Embed a 12" x 12" (30 x 30 cm) fiberglass mesh into themembrane, making sure it does not obstruct the drainage weep apply an additional coat of the membrane and smooth. Aftercuring, clamp the upper flange onto the membrane and tighten. Use asilicone caulk around the flange where the membrane and the upperflange make contact.

10 A toilet flange can be handled in much the as Crack Prevention MembraneForce RedGard into cracks with the flat side of the trowel, roller orbrush. Using a 3/16"-1/4" (5-6 mm) V-notch trowel or 3/8" ( mm)rough textured roller. Use the flat side of the trowel and flatten theridges to form a continuous, even coat of material. The membraneshould extend a minimum of the diagonal measurement of the tilebeyond both sides of the crack. Gaps between plywood sheets andwhere floors meet walls must also be prefilled. For continuous crackisolation, cover the entire substrate with RedGard applied at a rateof 100 sq. ft. per gallon. To meet the requirements of ANSI ,apply two coats of RedGard at a rate of 50 sq. ft. per gallon each as General Waterproof Membrane (ANSI )Cracks to 1/8" (3 mm) should be prefilled before beginningthe waterproofing application.