70-100 SERIES

Copyright 2016 Apollo Valves, Manufactured by Conbraco Industries - Printed in the USAA-3 Female NPT Thread, 600 CWP (psig), Cold Non-Shock. 150 psig Saturated Steam. (See referenced P/T charts)Vacuum Service to 29 inches SP-110 Two-piece body Reinforced seats Blow-out-proof stem design Adjustable packing glandVARIATIONS AVAILABLE:70-140 SERIES (316 SS Ball & Stem)70-190 SERIES (Locked Retainer)STANDARD MATERIAL LISTPARTMATERIAL1 Lever and gripSteel, zinc plated w/vinyl2 Stem packingMPTFE3 Stem bearingRPTFE4 BallB16 Brass, chrome plated5 Seat (2)RPTFE (1/4 to 3 ); TFM (4 )6 RetainerB16 Brass (1/4 to 1 )B584-C84400 ( to 4 )7 Gland nutB16 Brass8 StemB16 Brass9 Lever nutSteel, zinc plated10 Body sealPTFE ( to 4 )11 BodyB584-C84400 Bronze Ball Valve70-100 SERIESOPTIONS AVAILABLE: (More information in Section J) Minimum quantities apply To specify an option, replace the 01 standard suffix with the suffix of the option.

Copyrigt 2016 Apollo Vales, Manatre by Conbrao Instries - Printe in te USA A-3 Female NPT Thread, 600 CWP (psig), Cold Non-Shock. 150 psig Saturated Steam.

Tags:

  Series, 70 100 series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 70-100 SERIES

1 Copyright 2016 Apollo Valves, Manufactured by Conbraco Industries - Printed in the USAA-3 Female NPT Thread, 600 CWP (psig), Cold Non-Shock. 150 psig Saturated Steam. (See referenced P/T charts)Vacuum Service to 29 inches SP-110 Two-piece body Reinforced seats Blow-out-proof stem design Adjustable packing glandVARIATIONS AVAILABLE:70-140 SERIES (316 SS Ball & Stem)70-190 SERIES (Locked Retainer)STANDARD MATERIAL LISTPARTMATERIAL1 Lever and gripSteel, zinc plated w/vinyl2 Stem packingMPTFE3 Stem bearingRPTFE4 BallB16 Brass, chrome plated5 Seat (2)RPTFE (1/4 to 3 ); TFM (4 )6 RetainerB16 Brass (1/4 to 1 )B584-C84400 ( to 4 )7 Gland nutB16 Brass8 StemB16 Brass9 Lever nutSteel, zinc plated10 Body sealPTFE ( to 4 )11 BodyB584-C84400 Bronze Ball Valve70-100 SERIESOPTIONS AVAILABLE: (More information in Section J) Minimum quantities apply To specify an option, replace the 01 standard suffix with the suffix of the option.

2 To specify multiple options, replace the 01 suffix with the desired suffixes in the numerical order shown below. NOTE: Not all suffixes can be combined together.(SUFFIX)OPTIONSIZES -01 Standard ConfigurationAll-P -01-BSPP (Parallel) Thread Connection1/4 to 3 -T -01-BSPT (Tapered) Thread Connection1/4 to 3 -02-Stem Grounded1/4 to 4 Stem Extension (Carbon Steel, Zinc Plated)1/4 to 3 -05-Plain Ball1/4 to 3 -07-Steel Tee Handle1/4 to 2 -08-90 Reversed Stem1/4 to 3 -10-SS Lever & Nut1/4 to 3 -11-Therma-Seal Insulating Tee Handle1/4 to 2 -14-Side Vented Ball (Uni-Directional)1/4 to 4 -15-Wheel Handle, Steel1/4 to 2 -16-Chain Lever - Vertical 3/4 to 2 -17-Rough Chrome Plated - Bronze Valves1/4 to 3 -21 UHMWPE Trim (Non-PTFE)1/4 to 3 -24-Graphite Packing1/4 to 3 -27-SS Latch-Lock Lever & Nut1/4 to 4 -30-Cam-Lock and Grounded1/4 to 2 -32-SS Tee Handle & Nut1/4 to 2 -35-PTFE Trim1/4 to 3 -36-SS Hi-Rise Round Handle, SS Nut1/4 to 2 -39-SS Hi-Rise Locking Wheel Handle, SS Nut1/4 to 2 -40-Cyl-Loc and Grounded1/4 to 2 -41-Automatic Drain (Bronze Valves Only)

3 1/4 to 2 -45-Less Lever & Nut1/4 to 3 -46-Latch Lock Lever - Lock in Closed Position Only1/4 to 3 -47-SS Oval Latch-Lock Handle & Nut1/4 to 2 -48-SS Oval Handle (No Latch) & Nut1/4 to 2 -49-No Lubrication. Assembled to 4 CS Locking Stem Extension1/4 to 3 -56-Multifill Seats & Packing1/4 to 3 -57-Oxygen Cleaned1/4 to 4 -58-Chain Lever - Horizontal3/4 to 2 -60-Static Grounded Ball & Stem1/4 to 3 -63-NPT x Solder/Socket Weld3/8 to 4 -64-250# Steam Trim (MPTFE Seats & Packing)Use with 316 SS Ball & Stem Variation1/4 to 3 -92-Balancing Stop1/4 to 3 Stem Extension, Balancing Stop1/4 to 3 -HC-Hose Cap & Chain1/2 to 1 FOR PRESSURE/TEMPERATURE RATINGS, REFER TO PAGE M-10, GRAPH NO.

4 4 PRODUCT NUMBERSIZEABCDEW 2016 Apollo Valves, Manufactured by Conbraco Industries - Printed in the USAM-3 The listed Cv factors are derived from actual flow testing, in the Apollo Ball Valve Division, Conbraco Industries, Inc., Pageland, South Carolina. These tests were completed using standard off the shelf valves with no special preparation and utilizing standard schedule 40 pipe. It should be understood that these factors are for the valve only and also include the connection configuration. The flow testing is done utilizing water as a fluid media and is a direct statement of the gallons of water flowed per minute with a 1 psig pressure differential across the valve/connection unit.

5 Line pressure is not a factor. Because the Cv is a factor, the formula can be used to estimate flow of most media for valve sizing. For Apollo Ball ValvesFLOW DATACv FACTORS FOR APOLLO VALVESVALVESIZE (IN.)1/43/81/23 SERIES ----1530434884108 --------------70-600 SERIES ------30434884108190370----------7 1-100/200 SERIES ------30434884108190370----------7 2-100/900 SERIES ----264865125170216--------------7 3A-100 SERIES ----264865125170216--------------7 4-100 SERIES ----264865125170216--------------7 6-600 SERIES ----155168125177389503------------ 77-AR PSpGrQ = CV FLOW OF LIQUID Where:Q = flow in US gpm P = pressure drop (psig)SpGr = specific gravity at flowing temperatureCv = valve constant FLOW OF GAS Where.

6 Q = flow in SCFH P = pressure drop (psig)SpGr = specific gravity (based on air = )P2 = outlet pressure psia (psig + )T = (temp. F + 460)Cv = valve constant(Q)2 (SpGr)(Cv)2 or P =( P) (P2)(SpGr) (T)Q = 1360 CV x 10-7 (SpGr) (T) (Q)2(Cv)2 (P2) or P =CAUTION: The gas equation shown, is valid at very low pressure drop ratios. The gas equation is NOT valid when the ratio of pressure drop ( P) to inlet pressure (P1) exceeds : Only use the gas equation shown if (P1-P2)/P1 is less than on next Customer Service (704) 841-6000M-4 VALVESIZE (IN.)1/43/81/23 SERIES ------112435------------------77G- UL SERIES ----163668125177389--------------7 7-100/200 SERIES ------------170376--9961893------- -86A/86B SERIES ------------170376--9961893------- -87A-100 SERIES ------------8610423437567310991902 3890--87A-200 SERIES ----151975--1954105451021201648379 250151702239087A-700 SERIES ------------8610423437567310991902 3890--87A-900 SERIES ----151975--1954105451021201648379 250151702239087A-F00 SERIES --------75--195410545102120164837- -----87B-100 SERIES ------------------3756731099190238 90--87J-100 SERIES ------------8610423437567310991902 3890--87J-200

7 SERIES ----151975--1954105451021201648379 250151702239087J-700 SERIES ------------8610423437567310991902 3890--87J-900 SERIES ----151975--1954105451021201648379 250151702239087K-100 SERIES ------------8610423437567310991902 3890--87K-200 SERIES ----151975--1954105451021201648379 250151702239087K-700 SERIES ------------8610423437567310991902 3890--87K-900 SERIES ----151975--1954105451021201648379 250151702239088A-100 SERIES ------------8610423437567310991902 3890--88A-200 SERIES ----151975--1954105451021201648379 250151702239088A-700 SERIES ------------8610423437567310991902 3890--88A-900 SERIES ----151975--1954105451021201648379 250151702239088A-F00 SERIES --------75--195410545102120164837- -----88B-100 SERIES ------------------3756731099190238 90--89-100 Series6719345010426830962910181622------ --96-100 For Apollo Ball ValvesFLOW DATACv FACTORS FOR APOLLO VALVES (continued from M-3) Customer Service (704) 841-6000M-10600 CWPB ronze ASTM B584-C84400 (GRAPH 4)PRESSURE TEMPERATURE RATINGS400 CWPB ronze ASTM B584-C84400 (GRAPH 3)