1. 1. overview Compact series of entry-level keypads that gives complete control to wet ngers! is a compact keypad designed to be used with Aeware's spa systems. This new series of entry-level keypads comes in a waterproof plastic enclosure and is available in single pump, dual pump;. dual pump/blower or pump/blower con gurations. Easy to install, comes with an connector. Note: The spa control is also compatible with the following keypads: , , and Note: The following instructions are generic and provide a quick overview of the main functions. Please refer to your own QRC for speci c functions. 2. function description Smart winter mode Pump 1 Pump 2 Light Filter Heater Set Point indicator indicator indicator indicator indicator indicator indicator.

2 in.k200 overview in.k200 Compact series of entry-level keypads that gives complete control to wet fingers! In.k200 is a compact keypad designed to be used with

Tags:

  1999, 200k, 9919 100809, 100809

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 9919-100809 - Gecko Alliance Group

1 1. 1. overview Compact series of entry-level keypads that gives complete control to wet ngers! is a compact keypad designed to be used with Aeware's spa systems. This new series of entry-level keypads comes in a waterproof plastic enclosure and is available in single pump, dual pump;. dual pump/blower or pump/blower con gurations. Easy to install, comes with an connector. Note: The spa control is also compatible with the following keypads: , , and Note: The following instructions are generic and provide a quick overview of the main functions. Please refer to your own QRC for speci c functions. 2. function description Smart winter mode Pump 1 Pump 2 Light Filter Heater Set Point indicator indicator indicator indicator indicator indicator indicator.

2 Key 1 key 2 Light key Up/Down key 3. general speci cations Dimensions: General speci cations: Environmentals: Storage temperature: 70 C (158 F) to 30 C (-22 F). Operating temperature: 60 C (140 F) to 20 C (-4 F). 2" Humidity: 100% condensing (51 mm). Mechanical Specs: Weight: kg ( lbs). Dimensions (W x H x D): Front Panel: " 120 mm x 51 mm x 43 mm (120 mm). ( " x 2" x ") Soft gasket Standards: UV resistance (ASMT D4329). UL, CSA, TUV and CE. ". (43 mm). Speci cations and design are subject to change without notice. 4. installation & connections Installing the 2 5/8". The keypad should be installed directly onto the spa (or very 66 mm close to it) so that it is easily accessible to the user. To install the , drill two 1 (25 mm) diameter holes at 2 5/8 (67 mm) from center to center as illustrated.

3 Cut out the material between the two holes (see illustration). 1" 1". 25,4 mm 25,4 mm Clean the installation surface and peel the adhesive gasket from the back of the keypad. 1" dia. drill Insert keypad and align it correctly, then ensure it's properly glued by gently pressing evenly on the entire surface. Gasket with adhesive 1". 1". 2 5/8. ". 5. installation & connections Connecting main keypad to The comes with a 10 ft cable and an connector. To connect the , simply insert its connector into the appropriate keypad connector (as illustrated). Connect the main keypad as indicated here. 6. instructions . Key 1 Key 2 Key 2 (2 Pump/Blower) Light key Press Key 1 key to turn Pump 1 2 Pump (or single pump/ Press Key 2 to turn Pump 2 Press Light key to turn light on.)

4 On at low speed. Press a second blower) on at high speed. Pressing a Press Light key a second time to time to turn pump to high speed second time turns blower on. turn light off. (with a dual-speed pump). Press Key 2 key to turn Pump 2 A third press turns Pump 2 off A third time turns pump off. or Blower on. Press a second but leaves blower on. A nal A built-in timer automatically time to turn pump or Blower press turns blower off. A built-in turns light off after 2 hours, A built-in timer automatically off. timer automatically turns Pump unless it has been manually turns pump off after 20 min- 2/blower off after 20 minutes, deactivated rst. utes, unless pump has been A built-in timer automatically unless Pump 2/blower has manually deactivated rst.

5 Turns pump off after 20 min- been manually deactivated rst. The Light indicator lights up utes, unless pump or blower when light is on. The Pump 1 indicator lights has been manually deactivated The Pump 2 indicator lights up when Pump 1 is on. With rst. up when Pump 2/blower is on. dual-speed pump, indicator will ash when Pump 1 is on at The Pump 2 indicator lights low speed. up when Pump 2 or blower is on. 7. instructions . Up/Down key Programming lter cycles Setting lter cycle duration Filter cycle frequency Use Up or Down key to set Depending on system con gu- Press and hold Light key until Press Light key again. The desired water temperature. ration the system performs the display shows dxx, with "xx" display will show Fx, with "x". The temperature setting will either purge cycles or lter representing the duration in representing the number of be displayed for 5 seconds to cycles.

6 Hours. (Default: 2 hours). lter cycles per day (up to 4). con rm your new selection. (Default: twice a day). To program the lter cycles, you Use Up or Down key to change The "Set Point" icon indicates must enter these parameters: setting. Use Up or Down key to that the display shows the duration and frequency. During 0 = no ltration change setting. desired temperature, NOT the a lter cycle, pumps & blower 24 = continuous current water temperature! run at high speed for one ltration When the desired setting is minute to purge the plumbing. displayed, press Light key to Pump 1 or CP then runs at low Note: it's not recommended to con rm. A lter cycle will start speed for the remaining of the set this to "0". immediately. cycle. The Filter indicator lights up when a lter cycle is on.

7 8. instructions . Programming purge cycles Purge cycle frequency Water temperature regulation Smart Winter Mode To program the purge cycles, Press and hold Light key until In a regulation cycle, the system Our Smart Winter Mode you must select the frequency. the display shows Fx, with "x" rst generates water ow through protects your system from During a purge cycle, all pumps representing the number of the heater housing and the plumb- the cold by turning pumps on and the blower run for one purge cycles per day (up to 4). ing, in order to ensure accurate several times a day to prevent water temperature readings as water from freezing in pipes. minute. well as avoiding heater activation Use Up or Down key to change in dry conditions. The Smart Winter Mode.

8 Setting. indicator lights up when the After verifying pump activation Smart Winter Mode is on. When the desired setting is and taking a water temperature Cooldown displayed, press Light key to reading if required, the system After heating the spa water to the con rm. A purge cycle will start automatically turns the heater on to reach and maintain water desired Set Point, the heater is immediately. turned off, but its associated temperature at Set Point. pump (Pump 1 Low-speed or CP). The Filter indicator lights up The Heater indicator lights up remains on for a certain amount when a purge cycle is on. when the heater is on. It ashes of time to ensure adequate coo when there is a request for more ling of the heating element, this heat but the heater has not yet prolongs its useful life.

9 The hea- started. ter icon ashes during this time. 9. summary Keypads available for the : Typical settings: (LED display, 4 keys, 7 light indicators) Set Point : 59 F to 104 F / Factory set at 95 F. (LED display, 4 keys, 7 function icons) Filter Cycle Duration: 0 to 24 hrs / Factory set at 2hrs (LED display, 6 keys, 8 function icons) Filter Cycle Frequency: 1 to 4 times a day / Factory set at 2. (LCD display, 6 keys, 10 function icons) Filter Cycle Start: 00:00 to 23:59 / Factory set at 12:00. Pump Runtime: 1 to 255 min. / Factory set at 20 min. Light Timeout: 1 to 255 min. / Factory set at 120 min. Max Set Point: 59 F to 104 F / Factory set at 104 F. 10. Advanced electronics! Water resistance! Gecko Alliance 450 des Canetons, Quebec City (QC) G2E 5W6 Canada, 9225 Stellar Court, Corona, CA 92883 USA , 9919- 100809 .