Example: confidence

ACP 15 - hakuto-vacuum.jp

166 / Part Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air Cooled / acp 15 acp 15 Dry, compact multi-stage Roots pumps with a pumping speed of max. 14 m3/hDue to frictionless design, no contamination through particles: no wearing parts in the path of the gas flow QNo hydrocarbon vapor backstreaming: pumps in the ACP series are lubricant-free in the pumping module QConstant performance (pumping speed, maximum continuous inlet pressure and ultimate pressure) QHigh reliability: thanks to extensive experience with dry Roots pumps since 1988 QLow maintenance costs: no annual service, complete overhaul only every 20,000 hours ( acp 15 ) QSuitable for condensable vapors: with gas ballast and drainable silencerDimensionsACP 15 pumping speedACP 15 pump down time150185300861909347549920327010285410 24051440 Inlet DN 25 ISO-KFOutletDN 16 ISO-KF010520251540353010-210-11001011021 03S [m3/h]p [hPa] acp 15 0 1020304050607080 90p (hPa)T (min) acp 15 , 50 Hz, Inlet pressure drop10-110-2100101102103 Multi-stage Roots / Page Vacuum generation / Multi-stage Roots pumps / Light duty Applications / Air Cooled / acp 15 Technical dataACP 15, standardACP 15, G versionDimensions (L x W x H)514 x 190 x 270 mm 514 x 190 x 270 mmFlange (out)DN 16 ISO-KFDN 16 ISO-KFFlange (in)DN 25 ISO-KFDN 25 ISO

Page 168 / Part 3.1 www.pfeiffer-vacuum.com 3.1 Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air cooled / ACP 15 Order number guide ACP 15

Tags:

  Acp 15

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ACP 15 - hakuto-vacuum.jp

1 166 / Part Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air Cooled / acp 15 acp 15 Dry, compact multi-stage Roots pumps with a pumping speed of max. 14 m3/hDue to frictionless design, no contamination through particles: no wearing parts in the path of the gas flow QNo hydrocarbon vapor backstreaming: pumps in the ACP series are lubricant-free in the pumping module QConstant performance (pumping speed, maximum continuous inlet pressure and ultimate pressure) QHigh reliability: thanks to extensive experience with dry Roots pumps since 1988 QLow maintenance costs: no annual service, complete overhaul only every 20,000 hours ( acp 15 ) QSuitable for condensable vapors: with gas ballast and drainable silencerDimensionsACP 15 pumping speedACP 15 pump down time150185300861909347549920327010285410 24051440 Inlet DN 25 ISO-KFOutletDN 16 ISO-KF010520251540353010-210-11001011021 03S [m3/h]p [hPa] acp 15 0 1020304050607080 90p (hPa)T (min) acp 15 , 50 Hz, Inlet pressure drop10-110-2100101102103 Multi-stage Roots / Page Vacuum generation / Multi-stage Roots pumps / Light duty Applications / Air Cooled / acp 15 Technical dataACP 15, standardACP 15, G versionDimensions (L x W x H)514 x 190 x 270 mm 514 x 190 x 270 mmFlange (out)DN 16 ISO-KFDN 16 ISO-KFFlange (in)DN 25 ISO-KFDN 25 ISO-KFWeight23 kg23 kgHelium leak rate, 10-8 Pa m3/s5 10-8 Pa m3/sContinuous inlet pressure, hPa1013 hPaCorrosive gas Yes (light duty)CoolingAirAirPower consumption at ultimate pressure450 W450 WN2 purge gas flow, min.

2 5 slmMains requirement: Voltage100-230 V +/-10%, 50/60 Hz, 200-440 V +/-10%, 50/60 Hz100-230 V +/-10%, 50/60 Hz, 200-440 V +/-10%, 50/60 HzProcessesClean ProcessesLight duty applicationsPumping speed, m3/h14 m3/hTypical ultimate hPaTypical ultimate pressure with gas hPa Typical ultimate pressure with N2 purge hPaAmbient temperature12 to 40 C12 to 40 CVersionStandardCorrosive gas Water vapor capacity, g/h AccessoriesExternal silencer ES 25 S, DN 25109873109873 Noise Reduction Cover NRC 15, for acp 15 pumps111968111968 Sound Enclosure kit SEK 15, for acp 15 pumps112779112779 Multi-stage Roots 168 / Part Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air cooled / acp 15 Order number guide ACP 15V5aTSbcdFPump modelVersionsInlet port DN 25 Exhaust port DN 16 Gas ballastFrequency converterPower cordRubber feetACP 15SA, GATSM, B, R1)

3 , FF, TK, A, S, J, E, Z, R2) F1) R is the only option for G version2) R is the only option for three phased pumpMulti-stage Roots / Page Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air Cooled / acp 15 VersionsaSD versionSAG versionGAGas ballastbManual (On/Off)MBlankedBR 1/4 port (GA version) R1)Permanent filter (mesh) with defined gas throughputFFrequency converterc1-phaseF3-phaseTPower cordcUKKUSAS witzerlandSJapan (1 cable only)JEuropeEWithoutZ3-phase (without plug) R2)1) R is the only option for G version2) R is the only option for three phased pumpOrder number matrix acp 15 Order numberV5 a TS b c d FMulti-stage Roots pumps


Related search queries