174 / Part Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air Cooled / ACP 40 ACP 40 Dry, compact multi-stage Roots pumps with a pumping speed of max, 37 m3/h QDue to frictionless design, no contamination due to particles: no wearing parts in the path of gas flow QNo hydrocarbon vapor backstreaming: pumps in the ACP series are lubricant-free in the pumping module QConstant performance (pumping speed, maximum continuous inlet pressure and ultimate pressure) QHigh reliability: thanks to extensive experience with dry Roots pumps since 1988 QLow maintenance costs: no annual service, complete overhaul only every 22,000 hours for the ACP 28/40 QSuitable for condensable vapors: with gas ballast and drainable silencers.

Page 176 / Part 3.1 www.pfeiffer-vacuum.com Order number guide ACP 40 V8 a CSbcd e Pump model Versions Inlet / Exhaust Motor Frequency converter Power cord Gas ballast Options ACP 40 SA, GA, GV DN 40/

Tags:

  Pfeiffer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ACP 40 - hakuto-vacuum.jp

1 174 / Part Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air Cooled / ACP 40 ACP 40 Dry, compact multi-stage Roots pumps with a pumping speed of max, 37 m3/h QDue to frictionless design, no contamination due to particles: no wearing parts in the path of gas flow QNo hydrocarbon vapor backstreaming: pumps in the ACP series are lubricant-free in the pumping module QConstant performance (pumping speed, maximum continuous inlet pressure and ultimate pressure) QHigh reliability: thanks to extensive experience with dry Roots pumps since 1988 QLow maintenance costs: no annual service, complete overhaul only every 22,000 hours for the ACP 28/40 QSuitable for condensable vapors: with gas ballast and drainable silencers.

2 DimensionsACP 40 pumping speedACP 40 pump down time62720250 (inlet and exhaust) DN 25 ISO-KF for ACP 28 Inlet DN 40 ISO-KF for ACP 40 Outlet DN 25 ISO-KF0 1020304050607080 90p (hPa)T (min)ACP 40, 50 Hz, Inlet pressure drop10-110-21001011021030105202515403530 10-210-1100101102103S [m3/h]p [hPa]ACP 40 Multi-stage Roots / Page Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air Cooled / ACP 40 Technical dataACP 40, standard ACP 40, G versionACP 40, CV versionDimensions (L x W x H)647 x 193 x 322 mm 647 x 193 x 322 mm 647 x 308 x 322 mmFlange (out)DN 25 ISO-KFDN 25 ISO-KFDN 25 ISO-KFflange (in)DN 40 ISO-KFDN 40 ISO-KFDN 40 ISO-KFWeight32 kg32 kg32 kgHelium leak rate, 10-8 Pa m3/s5 10-8 Pa m3/s5 10-8 Pa m3/sContinuous inlet pressure.

3 HPa1013 hPa1013 hPaCorrosive gas Yes (light duty)Yes (light duty)CoolingAirAirAirPower consumption at ultimate pressure700 W700 W700 WN2 Sperrgasfluss, min3,7 SlmMains requirement: Voltage100 230 V +/-10%, 50/60 Hz, 200 440 V +/-10%, 50/60 Hz100 230 V +/-10%, 50/60 Hz, 200 440 V +/-10%, 50/60 Hz100 230 V +/-10%, 50/60 Hz, 200 440 V +/-10%, 50/60 HzProcessesClean ProcessesLight duty applicationsLight duty applicationsPumping speed, m3/h37 m3/h37 m3/hTypical ultimate hPaTypical ultimate pressure with gas hPa hPaTypical ultimate pressure with N2 purge hPa Ambient temperature 12 to 40 CVersionStandardCorrosive gas For condensable gasesWater vapor capacity.

4 G/h 700 g/hAccessoriesInlet particle filter IPF 40, DN40111647111647111647 External silencer ES 25 S, DN 25109873109873109873 Noise Reduction Cover NRC 28/40, for ACP 28 and ACP 40 112637112637 Sound Enclosure Kit SEK 28/40, for ACP 28 and ACP 40114379114379 Multi-stage Roots 176 / Part number guide ACP 40V8aCSbcdePump modelVersionsInlet / ExhaustMotorFrequency converterPower cordGas ballastOptionsACP 40SA, GA, GVDN 40/DN 25SF, TK, A, S, J, E, Z, R1)M, B2), F, V3), H3)F, R1) R is the only option for 3-phased pumps2) B is the only option for G version3) V or H are the only options for CV Vacuum generation / Multi-stage Roots pumps / Light duty Applications / Air Cooled / ACP 40 Multi-stage Roots / Page 177 VersionsaSD versionSAG versionGACV versionGVFrequency converterb1-phaseF3-phaseTPower cordcUKKUSAS witzerlandSJapan (1 cable only)JEuropeEWithoutZ3-phase (without plug) R1)Gas ballastdManual (On/Off)MBlanked B2)Permanent filter (mesh)FManual (On/Off) (CV version) V3)Permanent filter (CV version) H3)OptionseRubber feetFWheelsR1)

5 R is the only option for 3-phased pumps2) B is the only option for G version3) V or H are the only options for CV versionsOrder number matrix ACP 40 Order numberV8 a CS b c d Vacuum generation / Multi-stage Roots pumps / Light Duty Applications / Air Cooled / ACP 40 Multi-stage Roots pumps