Transcription of ACPL-P340/ACPL-W340 Data Sheet
1 Broadcom Confidential- 1 -DescriptionThe ACPL-P340/W340 contains an AlGaAs LED, which is optically coupled to an integrated circuit with a power output stage. This optocoupler is ideally suited for driving power IGBTs and MOSFETs used in motor control inverter applications. The high operating voltage range of the output stage provides the drive voltages required by gate controlled devices. The voltage and high peak output current supplied by this optocoupler make it ideally suited for direct driving igbt with ratings up to 1200V/50A. For IGBTs with higher ratings, this optocoupler can be used to drive a discrete power stage which drives the igbt gate. The ACPL-P340 and ACPL-W340 have the highest insulation voltage of VIORM = 891 Vpeak and VIORM = 1140 Vpeak respectively in the IEC/EN/DIN EN 60747-5-5. Functional DiagramACPL-P340 Amp output current igbt Gate drive optocoupler with Rail-to-Rail output Voltage in Stretched SO6 Data SheetFeatures maximum peak output current minimum peak output current Rail-to-rail output voltage 200 ns maximum propagation delay 100 ns maximum propagation delay difference LED current input with hysteresis 35 kV/ s minimum Common Mode Rejection (CMR) at VCM = 1500V ICC = mA maximum supply current Under Voltage Lock-Out protection (UVLO) with hysteresis Wide operating VCC Range: 15V to 30V Industrial temperature range: 40 C to +105 C Safety Approval: UL Recognized 3750V/5000 VRMS for 1 min.
2 CSA IEC/EN/DIN EN 60747-5-5 VIORM = 891V/1140 VpeakApplications igbt /MOSFET gate drive AC and Brushless DC motor drives Renewable energy inverters Industrial inverters Switching power suppliesNote: A 1 F bypass capacitor must be connected between pins VCC and : It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD. The components featured in this data Sheet are not to be used in military or aerospace applications or environments. VCCVEE123654 CATHODENCANODEVOUTCATHODENCANODEB roadcom Confidential- 2 - ACPL-P340/ACPL-W340 Data SheetOrdering InformationACPL-P340 is UL Recognized with 3750 VRMS for 1 minute per UL1577. ACPL-W340 is UL Recognized with 5000 VRMS for 1 minute per NumberOptionPackageSurface MountTape and ReelIEC/EN/DIN EN 60747-5-5 QuantityRoHS CompliantACPL-P340 ACPL-W340-000 EStretchedSO6X100 per tube-500 EXX1000 per reel-060 EXX100 per tube-560 EXXX1000 per reelTo order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry.
3 Example 1: ACPL-P340-560E to order product of Stretched SO6 Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-5 Safety Approval in RoHS 2: ACPL-W340-000E to order product of Stretched SO6 Surface Mount package in Tube packaging and RoHS data sheets are available. Contact your Broadcom sales representative or authorized distributor for Table LEDVCC VEEPOSITIVE GOING (TURN-ON)VCC VEENEGATIVE GOING(TURN-OFF)VOOFF0 30 V0 30 VLOWON0 V0 30 30 VHIGHB roadcom Confidential- 3 - ACPL-P340/ACPL-W340 Data SheetPackage Outline DrawingACPL-P340 Stretched SO6 Package (7 mm Clearance) ACPL-W340 Stretched SO6 Package (8 mm Clearance)7 7 45 5 ( ) ( ) BSG* + 07 7 ( ) ( ) ( ) ( ) + ()1 ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )Land Pattern RecommendationFloating Lead Protusions max.
4 Mm ( )Dimensions in Millimeters (Inches)Lead Coplanarity = mm ( )Total package length (inclusive of mold ash): mm mm ( )45 7 7 2134567 7 ( ) ( )Floating Lead Protusions max. mm ( )Dimensions in Millimeters (Inches)Lead Coplanarity = mm ( )Total package length (inclusive of mold ash): mm mm ( )* + + () + + () ( ) BSG35 ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )Land Pattern RecommendationBroadcom Confidential- 4 - ACPL-P340/ACPL-W340 Data SheetRecommended Pb-Free IR ProfileRecommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be InformationThe ACPL-P340/W340 is approved by the following organizations:ULRecognized under UL 1577, component recognition program up to VISO = 3750 VRMS (ACPL-P340) and VISO = 5000 VRMS (ACPL-W340).
5 CSACSA Component Acceptance Notice #5, File CA 88324 IEC/EN/DIN EN 60747-5-5(Option 060 Only)Maximum Working Insulation Voltage VIORM = 891 Vpeak (ACPL-P340) and VIORM = 1140 Vpeak (ACPL-W340)IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)DescriptionSymbolACPL-P340 Option 060 ACPL-W340 Option 060 UnitInstallation classification per DIN VDE 0110/39, Table 1 for rated mains voltage 150 VRMS for rated mains voltage 300 VRMS for rated mains voltage 450 VRMS for rated mains voltage 600 VRMS for rated mains voltage 1000 VRMSI IVI IVI IIII IIII IVI IVI IVI IVI IIIC limatic Classification40/105/2140/105/21 Pollution Degree (DIN VDE 0110/39)22 Maximum Working Insulation VoltageVIORM8911,140 VpeakInput to output Test Voltage, Method b*VIORM = VPR, 100% Production Test with tm =1 sec, Partial discharge < 5 pCVPR1,6712,137 VpeakInput to output Test Voltage, Method a*VIORM = VPR, Type and Sample Test, tm =10 sec, Partial discharge < 5 pCVPR1,4261,824 VpeakHighest Allowable Overvoltage*(Transient Overvoltage tini = 60 sec)
6 VIOTM6,0008,000 VpeakSafety-limiting values maximum values allowed in the event of a failure Case TemperatureTS175175 C Input CurrentIS, INPUT230230mA output PowerPS, OUTPUT600600mWInsulation Resistance at TS, VIO = 500 VRS>109>109 *Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Broadcom Regulatory Guide to Isolation Circuits, AV02-2041EN for a detailed description of Method a and Method b partial discharge test : These optocouplers are suitable for safe electrical isolation only within the safety limit data. Maintenance of the safety data shall be ensured by means of protective circuits. Surface mount classification is Class A in accordance with CECC Confidential- 5 - ACPL-P340/ACPL-W340 Data SheetInsulation and Safety Related SpecificationsParameterSymbolACPL-P340 ACPL-W340 UnitConditionsMinimum External Air Gap (Clearance)L(101) from input terminals to output terminals, shortest distance through External Tracking (Creepage)L(102) from input terminals to output terminals, shortest distance path along Internal Plastic Gap (Internal Clearance) insulation distance conductor to conductor, usually the straight line distance thickness between the emitter and Resistance (Comparative Tracking Index)CTI>175>175 VDIN IEC 112/VDE 0303 Part 1 Isolation GroupIIIaIIIaMaterial Group (DIN VDE 0110, 1/89, Table 1)Note.
7 All Broadcom data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimensions are needed as a starting point for the equipment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit board, minimum creepage and clearance requirements must be met as specified for individual equipment standards. For creepage, the shortest distance path along the surface of a printed circuit board between the solder fillets of the input and output leads must be considered (the recommended Land Pattern does not necessarily meet the minimum creepage of the device). There are recommended techniques such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and clearances. Creepage and clearance distances will also change depending on factors such as pollution degree and insulation Maximum TemperatureTS 55+125 COperating TemperatureTA 40+105 COutput IC Junction TemperatureTJ125 CAverage Input CurrentIF(AVG)25mA1 Peak Transient Input current (<1 s pulse width, 300 pps)IF(TRAN)1 AReverse Input VoltageVR5 VHigh Peak output CurrentIOH(PEAK) Peak output CurrentIOL(PEAK) output Supply Voltage(VCC VEE)035 VInput current (Rise/Fall Time)tr(IN)/tf(IN)500nsOutput VoltageVO(PEAK) IC Power DissipationPO700mW3 Total Power DissipationPT745mW4 Lead Solder Temperature260 C for 10 sec.
8 , mm below seating planeRecommended Operating TemperatureTA 40+105 COutput Supply Voltage(VCC VEE)1530 VInput current (ON)IF(ON)716mAInput Voltage (OFF)VF(OFF) + Broadcom Confidential- 6 - ACPL-P340/ACPL-W340 Data SheetElectrical Specifications (DC)All typical values are at TA = 25 C, VCC VEE = 30V, VEE = Ground. All minimum and maximum specifications are at recommended operating conditions (TA = 40 C to +105 C, IF(ON) = 7 mA to +16 mA, VF(OFF) = to + , VEE = Ground, VCC = 15V to 30V), unless otherwise Level Peak output CurrentIOH = VCC 4V145 VO 15V6 Low Level Peak output = VEE + VEE 15V 7 High Level output Voltage VOHVCC = 100 mA 2, 168, 9 High Level output Voltage VOHVCCVIO = 0 mA, IF = 10 mA1 Low Level output = 100 mA5, 17 High Level Supply = 10 ,Cg = 25 nF, IF = 10 mA 4, 5 Low Level Supply = 10 ,Cg = 25 nF, VF = 0 VThreshold Input current Low to = 10 ,Cg = 25 nF, VO > 5V6, 7, 8 Threshold Input Voltage High to Forward = 10 mA13 Temperature Coefficient of Input Forward Voltage VF/ TA CIF = 10 mAInput Reverse Breakdown VoltageBVR5 VIR = 100 AInput CapacitanceCIN70pFf = 1 MHz, VF = 0 VUVLO ThresholdVUVLO+ > 5V, IF = 10 Confidential- 7 - ACPL-P340/ACPL-W340 Data SheetSwitching Specifications (AC)
9 Unless otherwise noted, all typical values are at TA = 25 C, VCC VEE = 30V, VEE = Ground; all minimum and maximum specifications are at recommended operating conditions (TA = 40 C to +105 C, IF(ON) = 7 mA to 16 mA, VF(OFF) = to + , VEE = Ground, VCC = 15V to 30V). Delay Time to High output LeveltPLH5098200nsRg = 10 , Cg = 25 nF,f = 20 kHz, Duty Cycle = 50%,IF = 7 mA to 16 mA,VCC = 15V to 30V8, 9, 10, 11, 12, 20 Propagation Delay Time to Low output LeveltPHL5095200nsPulse Width DistortionPWD2270ns10 Propagation Delay Difference Between Any Two PartsPDD (tPHL tPLH) 100 +100ns27, 2811 Rise TimetR43nsVcc = 30 V20 Fall TimetF40nsOutput High Level Common Mode Transient Immunity|CMH|3550 kV/ sTA = 25 C, IF = 10 mA, VCC = 30V, VCM = 1500V with split resistors2112, 13 output Low Level Common Mode Transient Immunity|CML|3550kV/ sTA = 25 C, VF = 0V, VCC = 30V, VCM = 1500V with split resistors12, 14 Package CharacteristicsAll typical values are at TA = 25 C.
10 All minimum/maximum specifications are at recommended operating conditions, unless other-wise Momentary Withstand Voltage*VISOACPL-P3403750 VRMSRH < 50%,t = 1 min., TA = 25 C15,17 ACPL-W3405000 VRMSRH < 50%,t = 1 min., TA = 25 C16,17 Input- output ResistanceRI-O>5012 VI-O = 500 VDC17 Input- output =1 MHzLED-to-Ambient Thermal ResistanceR11135 C/W18 LED-to-Detector Thermal ResistanceR1227 Detector-to-LED Thermal ResistanceR2139 Detector-to-Ambient Thermal ResistanceR2247*The Input- output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input- output continuous voltage rating. For the continuous voltage rating, refer to your equipment level safety specification or Broadcom Application Note 1074 entitled optocoupler Input- output Endurance Voltage. Broadcom Confidential- 8 - ACPL-P340/ACPL-W340 Data SheetNotes:1.