Example: tourism industry

AGCO - Rudolph Brothers

AGCO Paint Application Reference Guide P P Promo 265 The following are registered trademarks of AGCO Corporation, Duluth, Ga.: AGCO , the AGCO logo, the Ag-Chem logo, Cockshutt , Epsilon , Farmhand , Fendt , GLEANER , Glencoe , Hart-Parr , Heritage , Hesston , Lor-Al , Massey Ferguson , Minneapolis-Moline , New Idea , Oliver , RoGator , Spra-Coupe , Sunflower , TerraGator , Tidal Wave , Tye , Valtra , Vario , the WFE logo, and Willmar.

AGCO 2.8 VOC MACHINERY ENAMELS TECHNICAL DATA: Product Type 2.8 VOC Alkyd Enamel Gloss 90+ on 60° / 80+ on 20° Solids By Weight 57.5 By Volume 49.4 Weight per gallon 8.23

Tags:

  Acog

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of AGCO - Rudolph Brothers

1 AGCO Paint Application Reference Guide P P Promo 265 The following are registered trademarks of AGCO Corporation, Duluth, Ga.: AGCO , the AGCO logo, the Ag-Chem logo, Cockshutt , Epsilon , Farmhand , Fendt , GLEANER , Glencoe , Hart-Parr , Heritage , Hesston , Lor-Al , Massey Ferguson , Minneapolis-Moline , New Idea , Oliver , RoGator , Spra-Coupe , Sunflower , TerraGator , Tidal Wave , Tye , Valtra , Vario , the WFE logo, and Willmar.

2 The following are trademarks of AGCO Corporation: Allis-Chalmers , Ferguson , Fieldstart , Massey-Harris , SisuDiesel , AGCO SprayParts and White . Challenger is a registered trademark of, and is used with permission from, Caterpillar Inc., Peoria, Ill. All other brand names are property of their respective trademark owners. Contents Technical 1 AGCO Paint Application .. 11 AGCOStar and White Paint Application .. 21 White, Oliver Cockshutt, New 22 New 23 White and New 24 Hesston, SAME, Black Machine, 27 Massey Ferguson Paint Application .. 28 Challenger Paint Application.

3 42 Ag-Chem Pant Application .. 45 Sunflower Paint Application ..49 Paint 50 AGCO VOC MACHINERY ENAMELS TECHNICAL DATA: Product Type VOC Alkyd Enamel Gloss 90+ on 60 / 80+ on 20 Solids By Weight By Volume Weight per gallon Surface Metal, Fiberglass Reduction Up to 6:1 (Paint: Acetone) Hardener 6:1:1 (Paint: Renew Hardener REN4001:Acetone) Spreading Thickness 750 + sq. ft.

4 Per gallon Film thickness mils wet mils dry Surface temperature Minimum/Maximum 40 F/90 F Dry Time To Touch 2 4 hours To Handle 12 24 hours Full Cure 14 Days Recoat Time Within 30 minutes or after 36 hours of the last coat With Hardener Dry Time To Touch 30 60 minutes To Handle 4 6 hours Full Cure 14 Days Clean Up & Reducer ACETONE IMPORTANT: Use of other type of thinner will raise VOC level of paint.

5 Technical Assistance: 877-724-0597 Available In: Qts Gals Challenger Yellow 79023277 79023278 M1041 Red 651787M91 651786M91 Corporate Orange 79023273 79023272 Autumn Prime 79023275 79023274 Chassis Gray 79025182 For Use On: MASSEY FERGUSON Agricultural, Lawn & Garden, and Industrial Equipment.

6 CHALLENGER, HESSTON Features: VOC Compliant Matches Original Finish Superior Gloss & Color Retention Durable Outstanding Adhesion, Flexibility and Chip Resistance Description: A VOC compliant alkyd enamel designed to provide the extreme gloss and weathering performance of an acrylic with the ease of an alkyd application. Surface Preparation: The surface must be clean, dry and free of all dirt, rust and other foreign matter. Remove all loose, peeling or cracked paint. Feather sand (using 400 sandpaper) rough edges, followed by solvent wipe. Allow 10-20 minutes for solvent flash off. Prime bare metal.

7 Glossy surfaces must be lightly sanded to insure proper adhesion. Fiberglass: Scrub with foaming cleaner, rinse well and allow to dry. Sand fiberglass thoroughly to completely remove gloss and provide adhesion. Wipe surface with solvent and allow to dry. Galvanized: AGCO specifies galvanized surfaces be supplied dry, which eliminates the usual requirement to remove all oils from the surface. Remove all loose, peeling or cracked surface. Lightly sand (using 400 sandpaper) all new and aged galvanized surfaces to ensure good adhesion. Feather sand (using 400 sandpaper) rough edges, followed by solvent wipe.

8 Allow 10-20 minutes for solvent flash off. Priming: To insure best results, bare ferrous metal should be primed with AGCO Fast Dry Primers. AGCO Primers may be topcoated within 1 hours and should be topcoated within 5 days. If primer stands longer than 5 days, surface must be properly prepared again. Application: Stir thoroughly, using circular, lifting motion. Apply when surface and air temperatures range between 40 F-90 F. 1 Spray Application: Product is supplied at under VOC. It is formulated to spray at the viscosity supplied for most spray applicators. The paint may seem very thin this is normal for low VOC paint formulations.

9 If reduction is necessary, USE ONLY ACETONE. Add one part Acetone to 6 parts paint. Continuously stir paint while gradually adding Acetone. Exact reduction varies with type of spray equipment and air pressure used. Apply in light mist coats until desired appearance is achieved. Allow paint to become tacky between coats. Recommended recoat window is before 30 minutes or after 36 hours of the last coat. Start at the top of equipment and work down to eliminate dry spray which dulls the finish. With Hardener: (FOR PROFESSIONAL OR INDUSTRIAL USE ONLY) Add Renew Hardener 6:1:1, Paint:Hardener:Acetone. Allow mixture to set for 10-15 minutes before using, mix again thoroughly before application.

10 Do not mix more than will be used within a 6 hour period. Do not use material that has started to body. High temperatures will reduce pot life. Brush Application: This paint should not be thinned for brush application. Apply to small areas and brush out to an even uniform coat. Recoating: When more than one coat is desired, recoat within 30 minutes or after 36 hours of the last coat. Heavy film, high humidity or low temperatures will lengthen the recommended time interval before recoat. In those conditions, recoat should be tested on small, hidden areas. Spreading rate: 700 - 800 square foot per gallon, depending upon method of application and type of surface.


Related search queries