Example: quiz answers

Agency for Health Care Administration

Agency for Health care AdministrationASPEN: Regulation Set (RS)Page 1 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceTitle INITIAL COMMENTSS tatute or Rule Type Memo TagST - K0000 - INITIAL COMMENTSR egulation DefinitionInterpretive GuidelineThese guidelines are meant solely to provide guidance to surveyors in the survey OTHER STANDARDSS tatute or Rule NFPA 101- 2012 LSCType RuleST - K0001 - OTHER STANDARDSThe facility shall meet the Standards of: NFPA 101, Life Safety Code, (2012) all NFPA mandatory requirements adopted per NFPA 101, Chapter 32 and applicable Florida State Fire Marshal's Rules and Regulations: 58A-2, Florida Administrative Code: , Florida Statues: (1)(b) and the Florida Building Code 2010 edition 437. Hospice Facilities shall meet the provisions of NFPA 101, for (New), Chapters 32; or for (Existing), Chapters 33, as appropriate, whichever occupancy chapter provides the higher level of safety for any particular DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 2 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceTitle MULTIPLE OCCUPANCIESS tatute or Rule NFPA 101- 2012 LSCType RuleST - K0011 - MULTIPLE OCCUPANCIESM ultiple occupancies shall comply with and in buildings other than those meeting the requirement of Where i

Agency for Health Care Administration ASPEN: Regulation Set (RS) Printed 04/20/2015 Page 2 of 34 Aspen State Regulation Set: K 3.01 Life Safety Code for Hospice

Tags:

  Administration, Health, Agency, Care, Agency for health care administration

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Agency for Health Care Administration

1 Agency for Health care AdministrationASPEN: Regulation Set (RS)Page 1 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceTitle INITIAL COMMENTSS tatute or Rule Type Memo TagST - K0000 - INITIAL COMMENTSR egulation DefinitionInterpretive GuidelineThese guidelines are meant solely to provide guidance to surveyors in the survey OTHER STANDARDSS tatute or Rule NFPA 101- 2012 LSCType RuleST - K0001 - OTHER STANDARDSThe facility shall meet the Standards of: NFPA 101, Life Safety Code, (2012) all NFPA mandatory requirements adopted per NFPA 101, Chapter 32 and applicable Florida State Fire Marshal's Rules and Regulations: 58A-2, Florida Administrative Code: , Florida Statues: (1)(b) and the Florida Building Code 2010 edition 437. Hospice Facilities shall meet the provisions of NFPA 101, for (New), Chapters 32; or for (Existing), Chapters 33, as appropriate, whichever occupancy chapter provides the higher level of safety for any particular DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 2 of 34 Printed 04/20/2015 Aspen State Regulation Set.

2 K Life Safety Code for HospiceTitle MULTIPLE OCCUPANCIESS tatute or Rule NFPA 101- 2012 LSCType RuleST - K0011 - MULTIPLE OCCUPANCIESM ultiple occupancies shall comply with and in buildings other than those meeting the requirement of Where incidental to another occupancy, areas used as follows shall be permitted to be considered part of the predominant occupancy and shall be subject to the provisions of the Code that apply to the predominant 101 Life Safety Code (2012) , DefinitionInterpretive GuidelineTitle CONSTRUCTION TYPE (NEW)Statute or Rule NFPA 101-2012 LSC RuleST - K0012 - CONSTRUCTION TYPE (NEW)The facility meets the Standards for (New) construction type according to NFPA 101 Life Safety Code (2012):Small Facilities Chapter , (No special requirements.) and the Florida Building Code 2010 Facilities Chapter Large board and care facilities shall be limited to the building construction types specified in Table (see ), based on the number of stories in height as defined in , and the Florida Building Code 2010 DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 3 of 34 Printed 04/20/2015 Aspen State Regulation Set.

3 K Life Safety Code for HospiceTitle CONSTRUCTION TYPE (EXISTINGS tatute or Rule NFPA 101-2012 LSC RuleST - K0013 - CONSTRUCTION TYPE (EXISTINGThe facility meets the Standards for (Existing) construction type according to NFPA 101 Life Safety Code (2012) Small Facilities Chapter Large Facilities For (Prompt) Evacuations Capabilities, (No special requirements), (Slow) Evacuation Capabilities, , (Impractical Evacuation Capabilities) , and the Florida Building Code 2010 DefinitionInterpretive GuidelineTitle INTERIOR FINISH (NEW)Statute or Rule NFPA 101-2012 LSCType RuleST - K0014 - INTERIOR FINISH (NEW)The interior finish shall be in accordance with Section Interior wall and ceiling finish materials complying with Section shall be Class A, Class B, or Class C. Interior floor finish shall comply with Section Interior floor finish shall comply with or , as applicable. NFPA 101 Life Safety Code (2012) Small , & Large DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 4 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceTitle INTERIOR FINISH (EXISTING)Statute or Rule NFPA 101-2012 LSCType RuleST - K0015 - INTERIOR FINISH (EXISTING)The general interior finish of small facilities shall be in accordance with Section wall and ceiling finish materials complying with Section shall be as follows:(1) Class A or Class B in facilities other than those having prompt evacuation capability(2) Class A, Class B, or Class C in facilities having prompt evacuation capabilityThere are no requirements for interior floor general interior finish of large facilities shall be in accordance with Section wall and ceiling finish materials complying with Section shall be Class A or Class B.))

4 Interior floor finish, other than approved existing floor coverings, shall be Class I or Class II in corridors or exits. NFPA 101 Life Safety Code (2012) (Existing) Small , (Existing) Large DefinitionInterpretive GuidelineTitle CORRIDORS (NEW & EXISTING)Statute or Rule NFPA 101-2012 LSCType RuleST - K0017 - CORRIDORS (NEW & EXISTING)Corridors are separated from use areas by partitions Regulation DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 5 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for Hospicecomplying with NFPA 101 Life Safety Code (2012) in accordance with: (New) Small , (New) Large & , , (Existing) Small , and (Existing) Large CORRIDORS (OPENINGS)Statute or Rule NFPA 101-2012 LSCType RuleST - K0018 - CORRIDORS (OPENINGS)Openings in corridor walls having a fire resistance rating shall be protected Complying with NFPA 101 Life Safety Code (2012) and in accordance with.

5 (New) Small , (New) Large , (Existing) Small , and (Existing) Large DefinitionInterpretive GuidelineTitle VERTICAL OPENINGSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0020 - VERTICAL OPENINGSV ertical openings shall be enclosed or protected in accordance with NFPA 101 Life Safety Code (2012); (New) Small , (New) Large , (Existing) Small , , and (Existing) Large DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 6 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceTitle FACILITY DOORSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0021 - FACILITY DOORSF acility doors shall be in accordance with NFPA 101 Life Safety Code (2012) , (New) Small , (New) Large (Existing) Small , (Existing) Large DefinitionInterpretive GuidelineTitle INTERIOR STAIRS SMOKEPROOF ENCLOSURES tatute or Rule NFPA 101-2012 LSCType RuleST - K0023 - INTERIOR STAIRS SMOKEPROOF ENCLOSUREI nterior Stairs smokeproof enclosure shall be permitted in accordance with NFPA 101 Life Safety Code (2012) respectively.

6 NEW Small- , New Large- , Existing Small- , Existing Large- , and DefinitionInterpretive GuidelineTitle SMOKE BARRIER DOORSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0025 - SMOKE BARRIER for Health care AdministrationASPEN: Regulation Set (RS)Page 7 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceSmoke barrier doors are 20 Minute fire rated construction with vision panels of fire rated glazing. NFPA 101 Life Safety Code (2012) respectively: (New) Small- shall resist the passage of smoke only, (New) Large , thru , (Existing) Small & Large- No Requirements. NFPA 80 (2010)Regulation DefinitionInterpretive GuidelineTitle OCCUPANT LOADS tatute or Rule NFPA 101-2012 LSCType RuleST - K0026 - OCCUPANT LOADThe occupant load, in number of persons for whom means of egress and other provisions are required, shall be determined on the basis of the occupant load factors of Table that are characteristic of the use of the space, or shall be determined as the maximum probable population of the space under consideration, whichever is greater.

7 NFPA 101 Life Safety Code (2012) (New) & (Existing) Large Only & & Table DefinitionInterpretive GuidelineTitle HAZARDOUS AREASS tatute or Rule NFPA 101-2012 LSCType RuleST - K0029 - HAZARDOUS AREASH azardous areas shall be: Enclosed with one hour fire rated construction, and be sprinkler protected. Door assemblies shall Regulation DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 8 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for Hospicebe 1-3/4 inch Solid Bonded Core and Self Closing. NFPA 101 Life Safety Code (2012) & (New) Large , Table , & (Existing) Large REMOTE EGRESSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0032 - REMOTE EGRESSR emote egress shall be provided for each floor or fire section. NFPA 101 Life Safety Code (2012) , (New) Large & (Existing) Large DefinitionInterpretive GuidelineTitle EGRESS COMPONENTSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0033 - EGRESS COMPONENTSE gress components are arranged to provide a continuous path of escape and provide protection against fire and smoke from other parts of the building.

8 NFPA 101 Life Safety Code (2012) , , (New) Large & (Existing) Large DefinitionInterpretive GuidelineTitle STAIRS & SMOKE PROOF ENCLOSURESS tatute or Rule NFPA 101-2012 LSCType RuleST - K0034 - STAIRS & SMOKE PROOF for Health care AdministrationASPEN: Regulation Set (RS)Page 9 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceStairs and smoke proof enclosures are in accordance with NFPA 101 Life Safety Code (2012) Chapter 7, & , , (New) Small (New) Large & (Existing) Large & DefinitionInterpretive GuidelineTitle EXIT CAPACITYS tatute or Rule NFPA 101-2012 LSCType RuleST - K0035 - EXIT CAPACITYC apacity of exits (number of persons per unit of exit width) shall meet the standard of NFPA 101 Life Safety Code (2012) , , (New) Large & (Existing) Small (depending on Evacuation Capability), (Existing) Large , DefinitionInterpretive GuidelineTitle TRAVEL DISTANCE TO EXITSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0036 - TRAVEL DISTANCE TO EXITST ravel distance (exit access) to exits from any room door does not exceed (Depending on (New) or (Existing) & (Small) or (Large).)

9 NFPA 101 Life Safety Code (2012) , (New) Small , Large , (Existing) Small (Depending on Evacuation Capability), (Existing) Large DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 10 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceTitle EXITS-DEAD END CORRIDORSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0037 - EXITS-DEAD END CORRIDORSE xits have no dead ends. NFPA 101 Life Safety Code (2012) (New) Small (No Requirements) (New) Large (over 30 feet) & (Existing) Small (No Requirements) (Existing) Large (over 50 feet) DefinitionInterpretive GuidelineTitle EXIT ACCESSIBILITYS tatute or Rule NFPA 101-2012 LSCType RuleST - K0038 - EXIT ACCESSIBILITYExit access is arranged to be readily accessible at all times. NFPA 101 Life Safety Code (2012) & , (New) Large & (Existing) Large DefinitionInterpretive GuidelineTitle EXIT ACCESS CORRIDORS-WIDTHS tatute or Rule NFPA 101-2012 LSCType RuleST - K0039 - EXIT ACCESS for Health care AdministrationASPEN: Regulation Set (RS)Page 11 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceExit access corridors and aisles are clear, un-obstructed, and at least 60 inches wide (New) and 44 inches wide (Existing).

10 NFPA 101 Life Safety Code (2012) , (New) Large & (Existing) Large DefinitionInterpretive GuidelineTitle EXIT DOORS-WIDTHS tatute or Rule NFPA 101-2012 LSCType RuleST - K0040 - EXIT DOORS-WIDTHExit access and exit doors are side hinged and 32" wide (New) and (Existing 28"). Stair doors are at least 36" wide. NFPA 101 Life Safety Code (2012) , (New) Small (New) Large & (Existing) Small & (Existing) Large DefinitionInterpretive GuidelineTitle EGRESS RELIABILITYS tatute or Rule NFPA 101- 2012 LSCType RuleST - K0041 - EGRESS RELIABILITYM eans of egress are maintained for 101 Life Safety Code (2012) , DefinitionInterpretive for Health care AdministrationASPEN: Regulation Set (RS)Page 12 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceTitle NUMBER OF EXITSS tatute or Rule NFPA 101-2012 LSCType RuleST - K0042 - NUMBER OF EXITSAt least two remote exits shall be provided for every part or every 101 Life Safety Code (2012) , (New) Large & (Existing) DefinitionInterpretive GuidelineTitle Horizontal ExitsStatute or Rule NFPA 101-2012 LSCType RuleST - K0044 - Horizontal ExitsHorizontal exits, when provided, shall conform to code 101 Life Safety Code (2012) (2012) , (New) Large & (Existing) Large DefinitionInterpretive GuidelineTitle Egress LightingStatute or Rule NFPA 101-2012 LSCType RuleST - K0045 - Egress for Health care AdministrationASPEN: Regulation Set (RS)Page 13 of 34 Printed 04/20/2015 Aspen State Regulation Set: K Life Safety Code for HospiceAn adequate number of light fixtures (not emergency lights only) shall be provided to illuminate means of egress.