Example: bachelor of science

Air Conditioners Technical Data - daikintech.co.uk

RX-JV/GVWall Mounted UnitAir ConditionersTechnical 112/05/2010 8:21:31 RX-JV/GVWall Mounted UnitAir ConditionersTechnical 212/05/2010 8:21:48 split Sky Air Outdoor Units1 Outdoor Units R-410A RX-JV/GVTABLE OF CONTENTSRX-JV/GV1 Features .. 22 Specifications .. 3 Nominal Capacity and Nominal Input .. 3 Technical Specifications .. 4 Electrical Specifications .. 63 Electrical data .. 74 Capacity tables .. 8 Cooling/Heating capacity tables .. 85 Dimensional drawing & centre of gravity .. 14 Dimensional drawing .. 14 Centre of gravity .. 166 Piping diagram.. 187 Wiring diagram.. 20 Wiring diagram.

Split Sky Air • Outdoor Units 3 • Outdoor Units • R-410A • RX-JV/GV 2 Specifications 2-1 Nominal Capacity and Nominal Input RX20JV1B RX25JV1B RX35JV1B For combination

Tags:

  Data, Technical, Conditioners, Split, Air conditioners technical data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Air Conditioners Technical Data - daikintech.co.uk

1 RX-JV/GVWall Mounted UnitAir ConditionersTechnical 112/05/2010 8:21:31 RX-JV/GVWall Mounted UnitAir ConditionersTechnical 212/05/2010 8:21:48 split Sky Air Outdoor Units1 Outdoor Units R-410A RX-JV/GVTABLE OF CONTENTSRX-JV/GV1 Features .. 22 Specifications .. 3 Nominal Capacity and Nominal Input .. 3 Technical Specifications .. 4 Electrical Specifications .. 63 Electrical data .. 74 Capacity tables .. 8 Cooling/Heating capacity tables .. 85 Dimensional drawing & centre of gravity .. 14 Dimensional drawing .. 14 Centre of gravity .. 166 Piping diagram.. 187 Wiring diagram.. 20 Wiring diagram.

2 208 Sound data .. 24 Sound pressure spectrum .. 249 Operation range .. 312/05/2010 8:21:49 Outdoor Units R-410A RX-JV/GV split Sky Air Outdoor Units21 FeaturesOutdoor UniSplit Sky RX-JV/GVR-410A Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency Silent buttons on the remote control lower the operation sound of the outdoor unit by 3dBA. Inverter compressors continuously adjust compressor speed to actual demand, fewer power - consuming starts and stops result in decreased energy consumption (up tot 30%) and more stable 412/05/2010 8:21.

3 49 split Sky Air Outdoor Units3 Outdoor Units R-410A RX-JV/GV2 Specifications2-1 Nominal Capacity and Nominal InputRX20JV1 BRX25JV1 BRX35JV1 BFor combination indoor units + outdoor unitsIndoor UnitsFTX20JV1 BFTX25JV1 BFTX35JV1 BCooling ,400 Kcal/h1, ,8008,50011,300 Kcal/h1,7202,1502, ,90010,20013,000 Kcal/h2,2402,5803,270 Heating ,400 Kcal/h1, ,5009,60011,900 Kcal/h2,1502,4103, ,60013,60016,400 Kcal/h3,0103,4404,130 Piping Heat insulation Both liquid and gas pipesLiquid combination indoor units + outdoor LabelCoolingAHeatingAAnnual energy consumptionkWh2753654902-1 Nominal Capacity and Nominal InputRX50G2V1 BRX60G2V1 BRX71GV1 BFor combination indoor units + outdoor unitsIndoor UnitsFTX50GV1 BFTX60GV1 BFTX71GV1 BCooling ,50022,90029,000kcal/h5,1605,7607, ,8007,800kcal/h1,4601, ,10020,50024,200kcal/h4,3005,1606, ,30027,30034,800kcal/h6,6206,8808, ,8007,800kcal/h1,4601, ,80023,90028,000kcal/h4,9906,0207, 512/05/2010 8:21.

4 49 Outdoor Units R-410A RX-JV/GV split Sky Air Outdoor Units42 SpecificationsPower combination indoor units + outdoor LabelCoolingABBH eatingABCA nnual energy consumptionkWh3000335042502-2 Technical SpecificationsRX20JV1 BRX25JV1 BRX35JV1 BCasingColourIvory WhiteDimensionsUnitHeightmm550 Widthmm658 Depthmm275 PackingHeightmm616 Widthmm788 Depthmm359 WeightUnitkg282830 Packed Unitkg313134 Heat ExchangerDimensionsLengthmm670670647Nr of Rows112 Fin of Stages242424 Tube typeHi-Xa(7)FinTypeWaffle finFanTypePropellerQuantity111 Air Flow RateCooling (High)m (High)m (High)cfm1,0301,030975 Heating (High)cfm927927865 MotorQuantity111 ModelKFD-280-33-8 AMotorSpeed (nominal)Cooling (Low)rpm720720720 Cooling (High)rpm860860860 Heating (Low)rpm350350350 Heating (High)rpm860860860 FanMotorOutputW333333 MotorModelKFD-280-33-8 ATypePropellerCompressorQuantity111 MotorModel1YC23 AEXDATypeHermetically sealed swing compressorMotor OutputW750750750 Operation RangeCoolingMin CDB101010 Max CDB464646 HeatingMin CWB-15-15-15 Max CWB202020 Sound Level (nominal)CoolingSound PowerdBA606062 Sound Pressure (High)dBA464648 HeatingSound Pressure (High) Nominal Capacity and Nominal 612/05/2010 8:21.

5 49 split Sky Air Outdoor Units5 Outdoor Units R-410A RX-JV/GV2 SpecificationsRefrigerant OilTypeFVC50 KCharged connectionsLiquid (OD)Quantity111 Diameter (OD) (OD) (OD)mm181818 Piping LengthMaximumm151515 Additional Refrigerant (>10m)Installation height differenceMaximumm121212 Heat InsulationBoth liquid and gas pipesStandard AccessoriesItemInstallation manualQuantity111 ItemDrain plugQuantity111 NotesNominal cooling capacities are based on: indoor temperature: 27 CDB, CWB; outdoor temperature: 35 CDB, 24 CWB, : 5mNominal heating capacities are based on: indoor temperature: 20 CDB; outdoor temperature: 7 CDB, 6 CWB, : 5mNominal heating capacities are based on: indoor temperature:20 CDB, outdoor temperature:7 CDB, 6 CWB, length 5mNominal heating capacities are based on: indoor temperature: 20 CDB.

6 Outdoor temperature: 7 CDB, 6 CWB, : 5m2-2 Technical SpecificationsRX50G2V1 BRX60G2V1 BRX71GV1 BCasingColourIvory whiteDimensionsUnitHeightmm792900 Widthmm960925 Depthmm390 PackingHeightmm735770 Widthmm825900 Depthmm300320 WeightUnitkg4871 Packed Unitkg5379 Heat ExchangerDimensionsLengthmm845857Nr of Rows2 Fin of Stages3234 Tube type 8 Hi-XAFinTypeWaffle finTreatmentAnti-corrosion treatment (PE)FanTypePropellerAir Flow RateCooling (High)m (Low)m (High)cfm1,7271,7971,924 Cooling (Low)cfm1,4721,4971,624 Heating (High)m (Low)m (High)cfm1,5891,6351,624 Heating (Low)cfm1,4721,4971,624 MotorModelKFD-380-50-8 CMotorSpeed (nominal)Cooling (Low)

7 Rpm670680730 Cooling (High)rpm780810860 Heating (Low)rpm670680730 Heating (High)rpm720740730 FanMotorOutputW53662-2 Technical 712/05/2010 8:21:50 Outdoor Units R-410A RX-JV/GV split Sky Air Outdoor Units62 SpecificationsCompressorMotorModel2YC36 BXD#C2YC63 BXD#ATypeHermetically sealed swing compressorMotor OutputW1,201,101,92 Operation RangeCoolingMin CDB-10 Max CDB46 HeatingMin CWB-15 Max CWB18 Sound Level (nominal)CoolingSound PowerdBA616366 Sound Pressure (High)dBA474952 Sound Pressure (Low)dBA444649 HeatingSound Pressure (High)dBA484952 Sound Pressure (Low) OilTypeFVC50 KCharged LengthMaximumm30 Chargelessm10 Additional Refrigerant (for piping length exceeding 10m)

8 Heat InsulationBoth liquid and gas pipesStandard AccessoriesDrain socket1 Installation manual1 NotesCooling: indoor temp. 27 CDB, CWB; outdoor temp. 35 CDB, 24 CWB; equivalent piping length: 5mHeating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; equivalent refrigerant piping: 5mSL: The silent fan level of the air flow rate setting220V;3;230V;4;240V2-3 Electrical SpecificationsRX20JV1 BRX25JV1 BRX35JV1 BPower SupplyNameV1 Phase1~FrequencyHz505050 VoltageV220-230-240 CurrentNominal running current (RLA)Cooling (A) (A) current (cooling/heating) connectionsFor Power SupplyQuantity333 For connection with indoorQuantity444 RemarkEarth wire included2-3 Electrical SpecificationsRX50G2V1 BRX60G2V1 BRX71GV1 BPower SupplyNameV1 Phase1~FrequencyHz50 VoltageV220-230-240 CurrentNominal running current (RLA)

9 - - - - - - - - - - - - connectionsFor Power SupplyQuantity3 For connection with indoorRemarkEarth wire included2-2 Technical 812/05/2010 8:21:50 split Sky Air Outdoor Units7 Outdoor Units R-410A RX-JV/GV3 Electrical is based on the following conditions. Indoor temp. 27 C DB/19 C WB. Outdoor temp. 35 C allowable voltage variation between phases is 2%. wire size based on the larger value of of fuse, use circuit unit combinationPower supplyCompOFMIFMI ndoor unitOutdoor unitHz-VoltsVoltage rangeMCAMFARHzRLAWFLAWFLAFTX20JV1 BRX20JV1B50 - 220 Max. 50Hz 264 VMin. 50Hz - 23050 - 240 FTX25JV1 BRX25JV1B50 - 220 Max.

10 50Hz 264 VMin. 50Hz - 23050 - 240 FTX35JV1 BRX35JV1B50 - 220 Max. 50Hz 264 VMin. 50Hz - 23050 - 240 SYMBOLSMCA: Min. Circuit Amps (A)MFA: Max. Fuse Amps (A)RLA: Rated Load Amps (A)OFM: Outdoor Fan MotorIFM: Indoor Fan MotorFLA: Full Load Amps (A)W: Fan Motor Rated Output (W)RHz: Rated Operating Frequency (Hz) ' $127(6 5/$ LV EDVHG RQ WKH IROORZLQJ FRQGLWLRQV ,QGRRU WHPS & '% & :% 2 XWGRRU WHPS & '% 0D[LPXP DOORZDEOH YROWDJH YDULDWLRQ EHWZHHQ SKDVHV LV 6 HOHFW ZLUH VL]H EDVHG RQ WKH ODUJHU YDOXH RI 0&$ ,QVWHDG RI IXVH XVH FLUFXLW EUHDNHU 5; *5; *95 HSUHVHQWDWLYH XQLW FRPELQDWLRQ3 RZHU VXSSO\&RPS2)0,)0,QGRRU XQLW2 XWGRRU XQLW+] 9 ROWV9 ROWDJH UDQJH0&$0)$5+]5/$:)/$:)/$)7; *9 %5; *9 % 0D[ +] 90LQ +] 9 )7; *9 %5; * 9 % 0D[ +] 90LQ +] 9 )7; *9 %5.


Related search queries