Example: air traffic controller

Air-Cooled Split Systems - aireclima.com

52UN-PRC001-EN5253UN-PRC001-ENLIGHT COMMERCIAL RANGEAIR cooled Split SYSTEMS54UN-PRC001-ENMax. lengthMax. level differenceLine diameter(m)(m)(inches)Outdoor unitL3D2D1 GasLiquidTTA 07540142411/81/240182411/85/8 TTA 09040142411/81/240182411/85/8 TTA 10024102413/81/240182413/85/8 TTA 12018101813/81/240182413/85/8 TTA 12518101813/81/240182413/85/8 TTA 15040142411/81/240182411/85/8 TTA 15524102413/81/240182413/85/8 TTA 18024102413/81/240182413/85/8 TTA 20024102413/81/240182413/85/8 TTA 24018101813/81/240182413/85/8 TWA 07540141011/81/240181811/85/8 TWA 09040141011/81/240181811/85/8 TWA 10024101013/81/240181813/85/8 TWA 12018101013/81/240181813/85/8 TWA 15040141011/81/240181811/85/8 TWA 15524101013/81/240181813/85/8 TWA 18024101013/81/240181813/85/8 TWA 20024101013/81/240181813/85/8 TWA 24018101013/81/240181813/85/8 Air-Cooled Split systemsL3 Maximumline lengthsand diametersD2D1

57 UN-PRC001-EN LIGHT COMMERCIAL RANGE TWA General Data — Heat Pumps - 60 Hz 7½ Ton 10 Ton 15 Ton 20 Ton Single Compressor Single Compressor Dual Compressor Dual Compressor

Tags:

  System, Compressor, Cooled, Split, Air cooled split systems

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Air-Cooled Split Systems - aireclima.com

1 52UN-PRC001-EN5253UN-PRC001-ENLIGHT COMMERCIAL RANGEAIR cooled Split SYSTEMS54UN-PRC001-ENMax. lengthMax. level differenceLine diameter(m)(m)(inches)Outdoor unitL3D2D1 GasLiquidTTA 07540142411/81/240182411/85/8 TTA 09040142411/81/240182411/85/8 TTA 10024102413/81/240182413/85/8 TTA 12018101813/81/240182413/85/8 TTA 12518101813/81/240182413/85/8 TTA 15040142411/81/240182411/85/8 TTA 15524102413/81/240182413/85/8 TTA 18024102413/81/240182413/85/8 TTA 20024102413/81/240182413/85/8 TTA 24018101813/81/240182413/85/8 TWA 07540141011/81/240181811/85/8 TWA 09040141011/81/240181811/85/8 TWA 10024101013/81/240181813/85/8 TWA 12018101013/81/240181813/85/8 TWA 15040141011/81/240181811/85/8 TWA 15524101013/81/240181813/85/8 TWA 18024101013/81/240181813/85/8 TWA 20024101013/81/240181813/85/8 TWA 24018101013/81/240181813/85/8 Air-Cooled Split systemsL3 Maximumline lengthsand diametersD2D1

2 CompressorunitBlowerunitAir-cooledconden sing unitsBlower unitsTTA/TWA55UN-PRC001-ENLIGHT COMMERCIAL RANGEL arge capacity indoor and outdoor use within the retail, service, office warehouse andindustrial sectors. For buildings from 200 to air distribution can be carried out directly via theindoor unit or from a distance via a network of solutions vary depending on :- the space available for the indoor unit : horizontalcabinet, vertical cabinet or ceiling installation,- the space available for the outdoor unit : floorinstallation, installation at a height or in an indoor commercial applications (supermarkets,offices, )Flexibility of our blower unitsScroll technology on our axial fan condensing unitsFlexibility of installationIdeal units for existing duct networks thanks to its flexibilityon airflow and static alternative when you can not have aroof applicationFOR WHOM?

3 FOR WHAT?TRANE S ADVICETTA/TWA 075 - 120 TWE 150 - 240 Split - 20 TR56UN-PRC001-ENTWE+ - 20 TRSplit SystemTTA/TWA075 -120 THERMOSTATTWETTA/TWA150 - 240 TWE+TWAMain features :TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drivecentrifugal fan motor. Aluminium fin coil with copper-tubes. Galvanised steel panels. Removable condensate drain pan. Throwaway filters as standard. Thermal protection of the fanmotor winding. Expansion valve factory installed. Check valves for heat pump applications Expansion valveTTA/TWA outdoor units : 1 cooling circuit (size 075 to 120).2 cooling circuits (sizes 150 to 240). Scroll compressor (s). Internal thermal protection of the fan andcompressor motor windings.

4 Crankcase heater. Liquid line filter drier. Direct drive axial fan motor. Anti-recycle timer ( compressor ). Stop valves (gas and liquid) withbrazed connections. Aluminium fin coil and copper :TWE indoor unit : Supplemental heaters: electric, hot waterand steam. Low static drive kit. Oversized drive outdoor units : Low ambient speed controller (TTA only). Black epoxy : 24 V electro-mechanical control. Digital display electronic wall thermostats. TAYSTAT 570, non 038 programmable Remote line lengths anddiameters : See page limits :TWE + TTA/TWAC ooling modeHeating modeMin. outdoor air temperature+ 15 C standard- 15 C- 15 C with speed controllerMax. outdoor air temperature+ 45 C+ 20 C57UN-PRC001-ENLIGHT COMMERCIAL RANGE TWA General Data Heat Pumps - 60 Hz7 Ton10 Ton15 Ton20 TonSingle CompressorSingle CompressorDual CompressorDual CompressorTWA090A3, A4, AWTWA120A3, A4, AWTWA180B3, B4, BWTWA240B3, B4, BWCooling Performance1 Gross Cooling CapacityMatched Air Handler (MBH)91124182240 Heat Pump Only2 (MBH)91124182240 ARI Net Cooling Capacity (MBH)89120176234 EER4 Matched Air Handler (MBH) Pump Only2 (MBH) Unit Poer (kW) PerformanceARI Heating with Matched Air HandlerHigh Temperature Capacity (MBH)87122168234 system Temperature Capacity (MBH)5580106154 system 3-D Scroll1/Trane 3-D Scroll2/Trane 3-D Scroll2/Trane 3-D ScrollSound Rating (BELS) Data6No.

5 Refrigerant Circuits1111 Suction Line (in.) OD13/813/813/813/8 Liquid Line (in.) OD1/21/21/21/2 Outdoor Fan TypePropellerPropellerPropellerPropeller No. Used/Diameter (in)1/261/282/262/28 Drive Type/No. SpeedsDirect/1 Direct/1 Direct/1 Direct/1 CFM5890820011,78016,240No. Motors/HP1/.501 Refrigerant Charge (Field Supplied)(Lbs. of R-22) : (1) Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacityis net and includes the effect of fan motor heat. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360-00.(2) Condensing Unit Only Gross Cooling Capacity rated at 45 F saturated suction temperature and at 95 F ambient.

6 (3) ARI Net Cooling Capacity is calculated with matched blowercoil and 25 ft. of 13/8 , 1/2 OD interconnecting tubing. (4) EER is rated at ARI conditions and in accordance with DOE test procedures. (5) Sound Rating shown is tested in accordancewith ARI Standard 270 or 370. (6) Refer to refrigerant piping applications manual for line sizing and line length. (7) Refrigerant (operating) charge is for condensing unit (all circuits)with matching blower coils and 25 ft. of interconnecting refrigerant lines. All units are supplied with a small nitrogen holding charge General Data Heat Pumps - 50 HzTWA075 ATWA100 ATWA155 BTWA200 BCooling Performance1 Gross Cooling CapacityMatched Air Handler, MBH (kW)82 ( )109 ( )166 ( )216 ( )Heat Pump Only2 , MBH (kW)82 ( )105 ( )161 ( )209 ( )ARI Net Cooling Capacity380 ( )105 ( )160 ( )196 ( ) system Power Pump Only Power PerformanceARI Heating with Matched Air HandlerHigh Temperature Capacity, MBH (kW)75 ( )106 ( )151 ( )206 ( )Low Temperature Capacity, MBH (kW)47 ( )69 ( )95 ( )135 ( )CompressorNumber1122 Type3D Scroll3D Scroll3D Scroll3D ScrollARI Sound Rating (BELS) Data5No.

7 Refrigerant Circuits1122 Suction Line, in. (mm) ( ) ( ) ( ) ( )Liquid Line, in. (mm) ( ) ( ) ( ) ( )Outdoor Fan TypePropellerPropellerPropeller/Propelle rPropeller/PropellerNo. Used1122 Diameter, in. (mm) ( ) (711) ( ) (711/711)Drive TypeDirectDirectDirect/DirectDirect/Dire ctNo. Speeds1111 CFM6 , (m3 /h)4700 (7985)6700 (11382)9800 (16649)13400 (22764)No. Motors1122 Motor HP (kW) (.24) (.56) (.24) (.56)R-22 Refrigerant Charge, lb7 (kg) ( ) ( ) ( ) ( )Notes: (1) Cooling Performance is rated at 95 F (35 C) ambient, 80 F ( C) entering dry bulb, 67 F ( C) entering wet bulb and nominal cfm listed. ARI rating cfm is 350 cfm/tonfor this product. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat.

8 Units are suitable for operation to 20% ofnominal cfm. Rated accordance with ARI Standard 210. (2) Condensing Unit Only Gross Cooling Capacity rated at 45 F ( C) saturated suction temperature and at 95 F (35 C)ambient. (3) ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft ( m) of , OD interconnecting tubing. EER and/or SEER are rated at ARIconditions and in accordance with DOE test procedures. Integrated Part Load Value is based on ARI Standard 210/240/340. Units are rated at 80 F ( C) ambient, 80 F ( C)entering dry bulb, and 67 F ( C) entering wet bulb at ARI rated cfm. (4) ARI Sound Rating is rated in accordance with ARI Standard 270. (5) system Data based on maximumlinear length 80 ft ( m)Maximum lift: suction 60 ft ( m) liquid 60 ft ( m) For greater lengths, refer to refrigerant piping applications manual.

9 (6) Outdoor Fan cfm is ratedwith standard air-dry coil outdoor. (7) Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft ( m) of interconnecting refrigerant Hz Condensing Units7 Ton10 Ton10 Ton10 To n12 Ton15 Ton15 Ton20 TonCompressors:SingleSingleDualManifolde dDualDualManifoldedDualModel: TTA090A3, A4120A3, A4120B3, B4120C3, C4150B3, B4180B3, B4180C3, C4240B3, B4 Cooling Performance1 Gross Cooling Capacity (MBH)Matched Air Handler92128126126148182182246 Condensing Unit Only292128126126148182182246 ARI Net Cooling Capacity389124122122144176176238 EER4 Matched Air KW/Condensing Unit 1/3-D 2/Climatuff 2/Copeland 2/Climatuff 2/3-D 2/3-D 2/3-D TypeManifoldedManifoldedScrollScrollScro llScrollScrollScrollScrollScrollNo.

10 Motors/HP1 Rating (BELS) Data7No. Refrigerant Circuits11212212 Suction Line (in.) OD1 3/81 3/81 1/81 3/81 1/81 3/81 5/81 3/8 Liquid Line (in.) OD 3/8 3/8 5/8 Outdoor Fan - TypePropellerPropellerPropellerPropeller PropellerPropellerPropellerPropellerNo. Used/Diameter (in.)1/261/281/281/282/282/262/262/28 Cfm5,6708,1208,1208,1208,12010,90011,340 16,120No. Motors/HP1/.501 Charge (Field Supplied)(Lbs of R-22) Hz Condensing UnitsTTA075 ATTA085 ATTA100 ATTA100 BTTA100 CTTA125 BTTA155B TTA155 CTTA200 BCooling Performance1 Gross Cooling CapacityMatched Air Handler (MBH)8291111102108127166160216 Condensing Unit Only 2 (MBH)8091107102108127163155209 ARI Net Cooling Capacity 3 (MBH)7987107100106123161153209 system Power Unit Power Scroll 3-D Scroll 3-D Scroll Climatuff Scroll TandemClimatuff 3-D Scroll3-D Scroll Tandem 3-D ScrollNo.


Related search queries