40 KMC / 38 HDF40 KMQ / 38 QRFIn --- Ceiling Cassette Duct --- Free Split SystemSizes 018 to 036 Product DataThe ideal compliment to your ducted system when it is impracticalor prohibitively expensive to use LEADINGFEATURES / BENEFITSAN INEXPENSIVE AND CREATIVESOLUTION TO DESIGN 38 HDF(QRF) / 40 KMC (KMQ) series duct--free split systemsare a matched combination of an outdoor condensing unit and anindoor fan coil unit connected only by refrigerant tubing and in--ceiling cassette fan coils are ideal for retrofit ormodernization projects where a false ceiling is available. Thisselection of fan coils permits inexpensive and creative solutions todesign problems such as:SAdd--ons to current space where the existing systemcannot handle the space requirements. like a conference room,where the load compact in--ceiling cassette units require less than 12 inches( mm) of false ceiling space and the only part that is seen isan aesthetically pleasing grille that blends with most SOUND LEVELSFor applications like conference rooms or libraries where noise is aconcern, the in--ceiling cassette is the answer.

40KMC / 38HDF 40KMQ / 38QRF In---Ceiling Cassette Duct---Free Split System Sizes 018 to 036 Product Data The ideal compliment …

Tags:

  Product, Data, Product data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data - aireclima.com

1 40 KMC / 38 HDF40 KMQ / 38 QRFIn --- Ceiling Cassette Duct --- Free Split SystemSizes 018 to 036 Product DataThe ideal compliment to your ducted system when it is impracticalor prohibitively expensive to use LEADINGFEATURES / BENEFITSAN INEXPENSIVE AND CREATIVESOLUTION TO DESIGN 38 HDF(QRF) / 40 KMC (KMQ) series duct--free split systemsare a matched combination of an outdoor condensing unit and anindoor fan coil unit connected only by refrigerant tubing and in--ceiling cassette fan coils are ideal for retrofit ormodernization projects where a false ceiling is available. Thisselection of fan coils permits inexpensive and creative solutions todesign problems such as:SAdd--ons to current space where the existing systemcannot handle the space requirements. like a conference room,where the load compact in--ceiling cassette units require less than 12 inches( mm) of false ceiling space and the only part that is seen isan aesthetically pleasing grille that blends with most SOUND LEVELSFor applications like conference rooms or libraries where noise is aconcern, the in--ceiling cassette is the answer.

2 The indoor units arewhisper quiet. There are no compressors indoors, either in theconditioned space or directly over it, and there is none of the noiseusually generated by air being forced through sound ordinances and proximity to neighbors demand quietoperation, the 38 HDF/QRF unit is the right choice: The advanced,horizontal blow--through airflow design distributes air more evenlyover the OPERATIONIf security is an issue, outdoor and indoor units are connected onlyby refrigerant piping and wiring to prevent intruders from crawlingthrough ductwork. In addition, since 38 HDF/QRF units can beinstalled close to an outside wall, coils are protected from vandalsand severe INSTALLATIONThe small footprint of the outdoor unit provides additionalbenefits. Because they require minimal service and airflowclearances, the outdoor units can be located virtually anywhere --on the ground, roof, balcony, under a deck, or even mounted on anoutside compact in--ceiling cassette requires less than 12 inches ( ) of false ceiling and the 40 KMC018 unit fits into a 2 X 2 ( m X m) false units are fast and easy to install ensuring minimal disruptionto customers in the workplace and making them ideal for SERVICING ANDMAINTENANCES aving time and money was a big consideration when designingthese the indoor unit, opening the grille will allow a servicetechnician access to the control box and to remove the cleanablefilters.

3 There is even a plug to drain water from the condensate panif it is ever the outdoor unit, a single panel provides immediateaccess tothe isolated compressor and control compartment, allowing aservice technician to check the unit operation without a loss ofcondenser airflow. In addition, the blow--through design of theoutdoor section means that dirtaccumulates on the inside surfaceof the coil. Coils can be cleaned from the outside using a pressurehose and detergent without removing grilles or using fin RELIABILITYDuct--free split system indoor and outdoor units are designed toprovide years of trouble--free in--ceiling cassette units include protection against freeze--upand high evaporator temperatures on heat condensing units and heat pumps are also protected. There isa 3--minute time delay before the compressor will re--start. Anoversized accumulator, high and low pressure switches (or liquidline pressure switch on the heat pump), and compressor internaloverload protection will ensure a reliable system that is ideal forlight commercial ROOM COMFORTM aximum occupant comfort was key in the design of thein--ceiling cassette instance, the indoor unit is equipped with a motorized louversystem that provides optimum air distribution into the conditionedroom.

4 The user can select eight different louver operating modesto adjust the airflow according to their specific air can be distributed from four sides of the unit. This allowsthe unit to be installed in the center of the room. For applicationswhere the unit has to be installed near a wall or in a corner, aspecial kit is available to close one or two heat pumps, the controls have built--in features to automaticallycompensate for air stratification and avoid cold blow on start--up orduring OPERATIONThe duct--free split system design allows individual room heatingor cooling when required. There is no need to run large supply--airfans or chilled water pumps to handle a few spaces with uniqueload patterns. In addition, because air is moved only in the spacerequired, no energy is wasted moving air through CONTROLSThe in--ceiling cassette units have microprocessor--based controlsto provided the ultimate in comfort and efficiency.

5 Either a userfriendly wireless remote control or a wired controller provides theinterface between user and the variety of accessories simplify the installation process and helpmeet system requirements and weather conditions. See table ofavailable accessories on page LISTINGSAll systems are listed with AHRI (Air Conditioning, Heating &Refrigeration Institute), and , KMQ / 38 HDF,QRF3 MODEL NUMBER NOMENCLATUREOUTDOOR UNIT38 HDF3---01---018 Air---Cooled CondenserUnit TypeHDF--- Cooling OnlyQRF--- Heat PumpVoltage3--- 208/230---1---605 ---208/230---3---60*6 ---460 --- 3 --- 60*INDOOR UNIT40 KMC3---01---018 Fan Coil UnitUnit TypeKMC--- Cooling OnlyKMQ--- Heat PumpVoltage3--- 208/230---1---60 Nominal Capacity018--- 1 --- 1/2 Tons024--- 2 Tons030--- 2 --- 1/2 Tons036--- 3 TonsNominal Capacity018--- 1 --- 1/2 Tons024--- 2 Tons030--- 2 --- 1/2 Tons035 or 036--- 3 Tons*Size 035 or 036 only AHRI* CAPACITY RATINGSS ystem TypeOutdoor SectionIndoor SectionStandard CFMNetCoolingBTUHSEEREERHigh HeatOutdoorIndoorBTUHHSPFC ooling38 HDF018 --- --- --- 340 KMC018 --- --- --- 3172047017, --- --- --- 340 KMC024 --- --- --- 3172069023, --- --- --- 340 KMC03036--- --- ---3172091029.

6 --- --- --- 340 KMC03036--- --- ---3390091036, --- --- --- 540 KMC03036--- --- ---3390091036, --- --- --- 640 KMC03036--- --- ---3390091036, withElectric Heat38 HDF018 --- --- --- 340 KMQ01824--- --- ---3172069017, --- --- --- 340 KMQ01824--- --- ---3172069022, --- --- --- 340 KMQ03036--- --- ---3172091029, --- --- --- 340 KMQ03036--- --- ---3390091036, --- --- --- 540 KMQ03036--- --- ---3390091036, --- --- --- 640 KMQ03036--- --- ---3390091036, Pump38 QRF018 --- --- --- 340 KMQ01824--- --- ---3172069017, , --- --- --- 340 KMQ01824--- --- ---3172069022, , --- --- --- 340 KMQ03036--- --- ---3390091029, , --- --- --- 340 KMQ03036--- --- ---3390091033, , --- --- --- 540 KMQ03036--- --- ---3390091033, , --- --- --- 640 KMQ03036--- --- ---3390091033, , *Air Conditioning, Heating & Refrigeration InstituteLegendHSPF--- Heating Seasonal Performance FactorSEER--- Seasonal Energy Efficiency RatioNOTES:1.

7 Ratings are net values reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80_F ( ) db, 67_F ( ) wb airentering indoor unit and 95_F(35_C) db air entering outdoor unit. High Temperature Heating Standard: 70_F ( ) db air entering indoor unit and 47_F( ) db, 43_F ( ) wb air entering outdoor Ratings are based on 25 ft. ( m) of interconnecting refrigerant All system ratings are based on fan coil units operating at high fan speed. Consult Physical data tables for airflows at all available fan , KMQ / 38 HDF,QRF4 STANDARD FEATURES AND ACCESSORIESEase Of InstallationIndoor and Outdoor Compact SizeSOutdoor Unit Wall Mounting KitAOutdoor Unit Stacking KitABuilt---in Condensate PumpSComfort FeaturesMicroprocessor ControlsSAutomatic Air SweepSAir Direction ControlSAuto Restart FunctionSCold Blow Protection On Heat PumpsSAir Stratification CompensationSEmergency Run ModeSAuto Changeover on Heat PumpsSEnergy Saving FeaturesSleep ModeSStop/Start TimerSSafety And Reliability3 MinuteTimeDelayForCompressorSOver Current Protection For CompressorSCrankcase Heater (standard on 38 QRF---030,035)

8 AHigh and Low Pressure Switches on Cooling Only UnitsSHigh Pressure Switch and Loss of Charge Switch on HeatPumpSIndoor Coil Freeze ProtectionSIndoor Coil High Temperature Protection On Heat PumpsSCondenser High Temperature Protection On Heat PumpsSAccumulator On Cooling Only and Heat PumpsSEase Of Service And MaintenanceControl Box Accessible From Bottom of UnitSCleanable FiltersSDiagnosticsSTest ModeSLiquid Line Pressure TapsSSuction And Discharge Pressure TapsSApplication Flexibility208/230 and 460 3 Phase on Size 035 and 036 SLong Lines up to 200 feet (61 m) (accessories required)APower Ventilation KitALow Ambient Controls (---20 F / C)AKnock---out to run a duct from an adjacent roomAWind BafflesAWired or Wireless ControlsAZone ManagerAWarranty5 ---Year Compressor WarrantyS1 --- Year Parts WarrantySCompressor Extended Warranty Years 6 Thru 10 OAll Parts And Labor Years 2 Thru 5 OAll Parts And Labor Years 2 Thru 5,Compressor Years 6 Thru 10 OLegendSStandardA AccessoryOOptionalINDOOR UNIT ACCESSORIESG rilleTo maximize shipping efficiency.

9 The grille for the in--ceilingcassette is set up as an Supply Outlet ObstructionKitThis kit can be used when up to two discharge outlets need to beblocked in applications where the unit is installed close to a wall ora VentilationKitThis kit will allow up to 20% of outside air to be introduced intothe conditioned " FLEX DUCTAIRFLOWINSULATEDLIQUID LINEINSULATEDSUCTION LINEWEATHERPROOFFUSED DISCONNECTPER NEC4" FLEX DUCTPOWERVENTILATIONACCESSORYPOWERVENTIL ATIONA07268 Fig. 1 Power Ventilation KitRemote Control(33MC--UMC)To provide added flexibility of choosing the user interface methodwith the unit, a remote control or wired controller can be Control Locking MountKitThis kit can be used where there is a concern that the remotecontrol can be misplaced. This accessory locks the remote in Controller(33MC--URC)For applications where the use of a wireless remote control is notdesired, the 40 KMC/KMQ units can be controlled by means of awired , wall--mounted control with an LCD 2 Wall Mounted Control with LCD DisplayRoom Control Wiring Kit(33MC9005)Up to six units can be daisy--chained together and controlled byone wired remote controller.

10 A room control wiring kit is requiredfor each slave Manager(33MC--UZM)For applications where more sophisticated controls are required, aZone Manager that permits the connection of up to 32 differentindoor units, divided into a maximum of eight different zones, canbe used. Zone Manager Wiring Kit (33MC9004) is required toconnect different units to the zone ManagerZONE ..ZONE 1 ZONE 8 Remote ControlA08443 Fig. 3 Zone Manager Connection40 KMC, KMQ / 38 HDF,QRF5 OUTDOOR UNIT ACCESSORIESLow AmbientKitThe kit controls condenser fan cycling using a pressure switch. It isspecifically designed to cycle the outdoor fan--motor in response tosaturated condensing pressure. This device maintains a constantsaturated condensing temperature of 100_F 10_F ( ) at outdoor--air temperatures between 55_F and --20_F( ), and can be used on all outdoor unitswithout changing the outdoor fan StartControlThe Winter Start Control is a SPST delay relay.