Transcription of ALL AROUND THE HOUSE
1 AROUND THE HOUSECEILING FAN12/3 Romex SIMpull Type NM-BDOOR BELLBELL WIREA nnunciator WireSPRINKLERSPRINKLER WIREM ulti-ConductorLAMPLAMP CORDType SPTWALL SWITCH & RECEPTACLE12/2 Romex SIMpull Type NM-BTELEVISIONCOAXIAL CABLET elecommunicationLANDSCAPE LIGHTSLANDSCAPEL ighting CableTHERMOSTATTHERMOSTAT WIRELow Voltage Control CordFIRE ALARMSECURITY/FIRE ALARMCMR Shielded & UnshieldedSPEAKERSSPEAKER WIREP arallel Zip Type Cable220 VOLT OUTLET10/3 Romex SIMpull Type NM-BDATA, TELEPHONE &INTERCOMCATEGORY 3, 5e, 6 Riser & Plenum CablesA/C UNITNM Hook-up WhipWATER FOUNTAINUF-BUnderground FeederPAD TRANSFORMERURD TriplexPOLE TRANSFORMERM ultiplexService DropMETER BASESER or SEUBREAKER BOXSER or SEUWARNING: INSTALLATION OF ELECTRICAL WIRE CAN BE HAZARDOUS AND, IF DONE IMPROPERLY, CAN RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE.
2 THE ABOVE APPLICATIONS ARE GENERAL RECOMMENDATIONS WHERE SPECIAL CONDITIONS MAY EXIST, CONSULT A PROFESSIONAL ELECTRICIAN. FOR SAFE WIRING PRACTICES, CONSULT THE NATIONAL ELECTRICAL CODE AND YOUR LOCAL BUILDING/ ELECTRICAL THE RIGHT WIRE FOR THE JOBSOUTHWIRE COMPANYONE SOUTHWIRE DRIVE CARROLLTON, GEORGIA WIRE CHARTSAMPERAGE RATINGS*WIRE SIZE(AWG OR Kcmil)1412108643211/02/03/04/0 INDOOR & OUTDOOR WIRE1520304055708595 RHW, THHN, XHHW, SE, USE152030506585100115130150175200230 RHW, THHN,(XHHW & SE INDRY LOCATIONS)152030557595110130150170195225 260 RHW, THHN,(XHHW & SE INDRY LOCATIONS)
3 152545607585100115135150175205*Amperage ratings for insulated wire & cable rated 0-2000 volts, based on table 310-16 of the 2005 NEC for not more than 3 conductors in raceway or cable or earth (directory buried), & an ambient temperature of 30 C/86 F. Branch circuits only. Not Service CIRCUIT LENGTHS FOR VOLTAGE DROP*WIRE SIZE(AWG)152030405060708090100 1450 126550 101058055 81601208060 626019513010080 441030520515512010085 2665500330250200165140125110100 6155115806050 424518512595756055 229529520015012010085756560*Recommended maximum circuit lengths in feet for voltage systems of 120 volts.
4 For 240-volt systems, circuit lengths may be double. Note: Extremely long circuits can produce voltage losses whereby some electrical equipment may not operate properly. Following these recommended values should provide reasonable efficiency of WIRE (NM-B)APPLICATIONSGAUGE FAN WITH LIGHT 12/3 CENTRAL AIR CONDITIONER 30 AMPS10/3 CENTRAL AIR CONDITIONER 40 AMPS8/3 COMBINATION SWITCH & OUTLET14/2 COOK TOP APT. SIZE - UP TO 30 AMPS10/3 DISHWASHER12/2 DISPOSAL12/2 DOUBLE OVEN APT.
5 SIZE - UP TO 30 AMPS6/3 DOUBLE OVEN RANGE UP TO 45 AMPS - COPPER8/3 DOUBLE OVEN RANGE UP TO 55 AMPS - COPPER6/3 ELECTRIC DRYER UP TO 30 AMPS10/3 ELECTRIC RANGE UP TO 50 AMPS6/3 ELECTRIC WALL HEATER UP TO 1650 WATTS12/2 ELECTRIC WALL HEATER OVER 1650 WATTS10/2 EXHAUST FAN14/2 FURNACE14/2 GROUNDED OUTLET SMALL APPLIANCES12/2 LIGHTED MEDICINE CABINET14/2 LIGHTING FIXTURE14/2 LIGHTING FIXTURE WITH OUTLETS14/2 PORTABLE AIR COMPRESSOR12/2 ROOM AIR CONDITIONER12/2 SINGLE OVEN BUILT-IN UP TO 30 AMPS8/3 WALL LIGHT SWITCH12/2 WATER HEATER10/23-WAY LIGHT SWITCH UP TO 15 AMPS14/33-WAY LIGHT SWITCH UP TO 20 AMPS12/3 USE 12/2W/GROUND WITH WALL SWITCHES AND GROUND OUTLETS WHERE LOCAL CODES OUTDOOR WIRE (UF-B)APPLICATIONSGAUGE BUILDING 120V TO OUTLETS OVER 100 FT.
6 10/2 DETACHED BUILDING 240V TO OUTLETS OVER 100 FT. 10/3 DUSK TO DAWN LIGHT14/2 OUTDOOR POST LIGHT WITH OUTLET12/2 PATIO-POOL WATER PROOF OUTLET12/2 PATIO SPOTLIGHT14/2 SUB PANEL 40 AMP FOR RUNS OVER 75 FT., USE ONE GAUGE SIZE 8/3 SUB PANEL 55 AMP FOR RUNS OVER 75 FT., USE ONE GAUGE SIZE 6/3 SWITCH & GROUND OUTLET14/2 WATER FOUNTAIN6/3 METAL CLAD (MC)APPLICATIONSGAUGE CONDITIONER 30 AMPS10/3 BRANCH CIRCUIT10/2 ELECTRIC DRYER UP TO 30 AMPS10/3 GROUNDED OUTLET14/2 HOT TUB10/2 LIGHTING SWITCH12/2 OVEN/RANGE6/3 WATER HEATER10/3 CORDAPPLICATIONSGAUGE / CONDUCTOR& PRODUCT NAMEDATA, TELEPHONE & INTERCOMCAT 6, 5e, or 4 PAIR RISER, DOOR BELL18/2, 18/3, or 20/2 BELL WIRELAMP18/2, or 16/2 SPTLANDSCAPE LIGHT12, 14, or 16 LANDSCAPE CORDSECURITY/FIRE ALARM18/2, 18/4, 22/2 or 22/4 SECURITY WIRE SPEAKER14 16 or IN-WALL SPEAKER WIRESPRINKLER SYSTEM18/4.
7 18/5, or 18/7 SPRINKLER WIRETELEVISIONRG6 or RG6 QUAD SHIELDTHERMOSTAT18/2, 3, 5 or 7 THERMOSTAT WIREAMPERAGE ALLOWANCE FOR 3-WIRE SINGLE PHASE DWELLING SERVICESCOPPER SIZE (AWG)OR KCMILALUMINUM SIZE (AWG) OR KCMILSERVICE RATING (AMPS)66603210021/012512/01502/04/02003/ 02502254 2010 Southwire Company ALL AROUND THE HOUSE - 1020