supply line. NOTE: If replacing an existing dishwasher, it is recommended to install a new water line (see the “Tools and Parts” section at the front of the guide for part details) and drain hose (supplied) with the new dishwasher. ELECTRICAL REQUIREMENTS You Must Have: 120-volt, 60 Hz, AC-only, 15- or 20-amp, fused electrical supply
Tags:
Supply, Dishwasher, Undercounter, Undercounter dishwasher
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Bottom Mount Refrigerator
images.thdstatic.comDimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10635370B 2/15 2¹⁄₂" (6.3 cm) ¹⁄₂" (1.25 cm) To ensure proper ventilation for your refrigerator, allow for a ¹⁄₂" (1.25 cm) space on each side and at the top.
LAUNDRY ACCESSORY GUIDE
images.thdstatic.comLAUNDRY ACCESSORY GUIDE. This quick reference guide to laundry accessories will help to make sure you have what . you need for a successful installation in just 3 easy steps. ... If your home was built before 1996 and has only a 3-wire connection, purchase a 3-prong dryer power cord. LG recommends a 4-wire connection and a 4-prong dryer power cord.
Electric Residential Hybrid Water Heater
images.thdstatic.comElectric Residential Hybrid Water Heater The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, for the owner– operator, to explain the features, operation, safety precautions, maintenance and
Electric, Water, Residential, Heaters, Hybrid, Water heaters, Electric residential hybrid water heater
Unfinished Cabinetry orders deliver to the store within 3 ...
images.thdstatic.comTake in-stock cabinets home today or order through Express Options®. Express Options orders deliver to the store within 3 weeks; see an Associate or the Special Services Desk to place your order.* Most products are available when ordered through Express Options. In-Stock selection varies by store. Product Selection Unfinished
Electric Tankless Water heaters
images.thdstatic.comYour new electric tankless water heater features advanced water flow rate and temperature sensors designed to modulate power to the heating elements to maintain a user-selected output water temperature between 80°F (27°C) and 140°F (60°C) (subject to incoming water temperature and power of the selected heaters). ...
Electric, Water, Heaters, Tankless, Electric tankless water heaters
PERFORMANCE tankless electric water heaters offer ...
images.thdstatic.comPERFORMANCE™ tankless electric water heaters RHEEM PART NUMBER GPM RATING OF INSERTS PROVIDED CONNECTION SIZE RTE10001A 1.0, 1.5, 2.0 1/2" NPT RTE10001B 2.0, 3.0, 4.0, 5.0 3/4" NPT Optional Inline Flow Regulator • Enhanced outlet temperature control • Install on the outlet side of the heater • Limit maximum volume to the specified flow
Electric, Water, Heaters, Offer, Tankless, Electric tankless water, Tankless electric water heaters offer
PRODUCT GUIDE Interior & Exterior Doors (JPG013)
images.thdstatic.comInformation for Replacement weatherstrip Product Identification Weatherstrip Location Weatherstrip Type Color Amount Needed 1. Determine amount needed by measuring each piece to be replaced. Note the location on the door of each type of weatherstrip. 2. For each type of weatherstrip, add all measurements, then add an additional 10%. 3.
Guide, Information, Product, Doors, Exterior, Interior, Product guide interior amp exterior doors, Jpg013
Heavy Electric Utility Heater Model: EG7500DGP “USER’S ...
images.thdstatic.com“USER’S MANUAL AND OPERATING INSTRUCTIONS” MODEL: Before the first use of this heater, please read this USER’S MANUAL very carefully. This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most importantly, how to operate the heater in a safe and efficient manner.
Manual, Operating, Instructions, S manual and operating instructions
CONCRETE SUBFLOOR REQUIREMENTS NEW …
images.thdstatic.comApproved subfloors include concrete, plywood, OSB, particleboard, chipboard, hardwood (solid, engineered, parquet), tile (ceramic, terrazzo, stone, asbestos, peel and stick), non-cushion sheet vinyl, metal, VCT, DRIcore. Adhered and sound vinyl sheet goods, linoleum and resilient (VCT) tiles: Old vinyl and linoleum tiles or sheet goods normally ...
FOAMULAR
images.thdstatic.comof Owens Corning® ResidentialComplete® Wall Systems. *See actual warranty for complete details, limitations and requirements. **R-value means resistance to heat flow. The higher the R-value the greater the insulating power. †As manufactured, Fiberglas insulation is resistant to mold growth. However, mold growth can occur on
Related documents
ELECTRIC SERVICE INSTALLATION REQUIREMENTS
www.uesaz.comELECTRIC SERVICE INSTALLATION REQUIREMENTS . 5 2. Customer shall provide and install underground service conduit per Company specifications (according to the following and including Specification B, page 15). 3. Conduit size requirements: 100 AMP and 200 AMP Panels: Minimum* 2 ½ inch conduit * 2 ½ inch x 2 inch swedged reducer, bell to plain ...
MRXBOXAB-ECO2 MRXBOX-ECO2 100% - Nuaire
nuaire.infothe mains supply. NOTE: This unit must be earthed. The mains power supply cable should be connected to Supply a fixed wiring installation in accordance with current IEE wiring regulations. Technical - MRXBOX(AB)-ECO2 Electrical Details: MRXBOX(AB)-ECO2 Voltage: 230V 1ph 50Hz Consumption: 1.2 Amp DIMENSIONS (mm) Weight - 20kg Front View Side ...
Bottom Mount Refrigerator
images.thdstatic.comDimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10635370B 2/15 2¹⁄₂" (6.3 cm) ¹⁄₂" (1.25 cm) To ensure proper ventilation for your refrigerator, allow for a ¹⁄₂" (1.25 cm) space on each side and at the top.
MicroLogix 1000 Programmable Controllers
literature.rockwellautomation.comInstall your controller using these installation instructions. The only tools you require are a Flat head or Phillips head screwdriver and drill. Catalog Number Detail The catalog number for the controller is composed of the following: 1761 - L 20 A W A - 5 A Analog I/O Number of Analog I/O: 4 Inputs, 1 Output Power Supply A = 120/240V ac B ...
Commercial/Industrial/Large Residential Service Information
www.dteenergy.comFurnace Amp Electric Water Heater Amp Motors Amp Electric Resistance Heat Amp Fans Amp Motors Amp Well Pump (open loop system) Amp Other ... Located in Specification Manual for the select model number as FLA or Fully Loaded Amps for the total unit. ... You may also supply your concerns in writing when submitting the form.
WALK-IN BATH INSTALLATION INSTRUCTIONS AND …
walkintubs.americanstandard-us.comOWNERS MANUAL 6 INSTALLATION PREPARATION 1. Check the floor area where the tub is to be installed. a. Clean area of any debris or trash. …
UTILITY SERVICE ENTRANCE STANDARDS - NB Power
www.nbpower.com1200 Amp Fig. 6 Current Transformer Connected May Pole, 120/240V 400 Amp Fig. 7 Self-Contained May Pole, 120/240V to 200 Amp Fig. 8 Customer Owned Pole for Non-Fixed Premise Fig. 9 Temporary Service Entrance, Tripod Mounted Fig. 10 Outdoor Metering Fig. 11 Utility Metering Equipment - Summary Fig. 12 Installation of Metering Current Transformers
Services, Utility, Installation, Standards, Entrance, Utility service entrance standards