Aluminum Service Entrance Cable - Priority Wire

APPLICATION: Aluminum SER Cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90 C in wet or dry locations. Voltage rating is 600 : 8000 series Aluminum alloy, solid or compact strandedINSULATION: Type XHHW-2 cross-linked polyethylene (XLPE) CODE: ASSEMBLY: Two, three or four insulated conductors and a bare ground conductor cabled together and covered with a reinforced binder tapeJACKET: Gray sunlight resistant polyvinyl chloride (PVC) jacketSTANDARDS: UL 44: Thermoset-Insulated Wires and Cables UL 854.

conductors shall be permitted as listed ampacities to be utilized as 120/240-volt, 3-wire, single-phase service entrance conductors and feeder con-ductors that serve as the main feeder for NEC 310.15(B)(7). ©2021 Priority Wire & Cable 08-2021 Part Number Insulated Conductor Bare Conductor Nominal OD Approx. Weight Allowable Ampacities** Size ...

Tags:

  Allowable, Ampacities, Allowable ampacities

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Aluminum Service Entrance Cable - Priority Wire

1 APPLICATION: Aluminum SER Cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90 C in wet or dry locations. Voltage rating is 600 : 8000 series Aluminum alloy, solid or compact strandedINSULATION: Type XHHW-2 cross-linked polyethylene (XLPE) CODE: ASSEMBLY: Two, three or four insulated conductors and a bare ground conductor cabled together and covered with a reinforced binder tapeJACKET: Gray sunlight resistant polyvinyl chloride (PVC) jacketSTANDARDS: UL 44: Thermoset-Insulated Wires and Cables UL 854.

2 Standard for Service - Entrance Cables ASTM B-258, B-800, B-801 National Electric CodeAluminum Service Entrance Cable Type SE Style R (SER), 600V 90 C#1030-01 Aluminum BUILDING values are nominal and subject to correction.** ampacities shown are for general use as specified by the National Electric Code, 2017 Edition Table (B)(16). Dwelling For dwelling units, conductors shall be permitted as listed ampacities to be utilized as 120/240-volt, 3-wire, single-phase Service Entrance conductors and feeder con-ductors that serve as the main feeder for NEC (B)(7).

3 Part NumberInsulated ConductorBare ConductorNominal ODApprox. WeightAllowable ampacities **SizeNumber of StrandsSizeNumber of Strands75 C90 CDwellingAWG/kcmilAWG/kcmilinchesmmlbs/k ftTwo Conductor SER plus Bare Ground8-02 ALUMG-SER-SOL2 x x x x x x x x x 1 x 1/0181 x 2 x 2/0182 x 3/0181 x 4/0182 x 4/0184 #Color2 Black and Red3 Black, White, and Red4 Black, White, Red, and BlueAluminum Service Entrance Cable Type SE Style R (SER), 600V 90 C#1030-01 Aluminum BUILDING values are nominal and subject to correction.

4 ** ampacities shown are for general use as specified by the National Electric Code, 2017 Edition Table (B)(16). Dwelling For dwelling units, conductors shall be permitted as listed ampacities to be utilized as 120/240-volt, 3-wire, single-phase Service Entrance conductors and feeder con-ductors that serve as the main feeder for NEC (B)(7). 2021 Priority Wire & Cable08-2021 Part NumberInsulated ConductorBare ConductorNominal ODApprox. WeightAllowable ampacities **SizeNumber of StrandsSizeNumber of Strands75 C90 CDwellingAWG/kcmilAWG/kcmilinchesmmlbs/k ftThree Conductor SER plus Bare Ground8-03 ALUMG-SER-SOL3 x x x x x x x 1 x 2 x 3/0181 x 4/0182 x 250353 300354 Conductor SER plus Bare Ground2-04 ALUMG-R-SER4 x x 2 x 4/0182 x 250223