Transcription of Analysis Report 14.04770 - vescom.com
1 Vescom bvDhr. Ron VerlouwPostbus 705753 AV DEURNEN ederlandAnalysis Report notice ofYour referenceDate07-10-2014SO-111567207-07-2 015 Required tests :Clause 11 (upholstery composite) - Assessment of the ignitabilityof upholstered seating - crib ignition source no. 5BS 5852 (2006)07-10-2014 Namal 7043T1416153 Date of receiptInformation given by the clientIdentificationnumberThis Report runs to 3 pages and may be reproduced, as long as it is presented in its entire form, without written permission results of the Analysis cover the received samples. Centexbel is not responsible for the representativeness of the assessing compliance with the specifications, we did not take into account the uncertainty on the test Cr elleOrder responsibleCENTEXBEL-VERVIERSA venue du Parc 38BE-4650 Herve (Chaineux)Tel. + 32 87 32 24 30 Fax + 32 87 34 05 7BE-9052 ZwijnaardeTel. + 32 9 220 41 51 Fax + 32 9 220 49 BE44 2100 4729 6545 Fin. Acc. 210-0472965-45 VAT BE Report 35140 (Recticel) * - fire retardant foam - 35 kg/m * The filling complies with schedule 1 part 1 of the UKFurniture and Furnishings (Fire) (Safety) Regulations1988 FillingNoWater soaking of the coverThe following test results relate only to the ignitability of the combination of materials underthe particular conditions of test ; they are not intended as a means of assessing the fullpotential fire hazard of the materials in C, relative humidity 50%Conditioning-Deviation from the standardBS 5852 (2006)Standard used20-10-2014 Date of ending the testClause 11 (upholstery composite) - Assessment of the ignitability of upholstered seating -crib ignition source no.
2 5T1416153 - Namal 7043 Reference: Analysis Report - NI/5 Conclusionnon-ignition -NI/5non-ignition -NI/54 min 17 s3 min 55 sFlame timenonoFlame time >10 minnonoFlames through thicknessnonoFlames to extremitiesnonoTest assembly consumednonoUnsafe escalating combustionFlaming criterianonoSmoulders more than 100 mm from sourcenonoSmoke, heat or glowing more than 1 hournonoSmoulders through thicknessnonoSmoulders to extremitiesnonoTest assembly consumednonoUnsafe escalating combustionSmouldering criteria21 Performed under accreditation in the fire lab under the responsibility of Nathan De Kock