Example: bachelor of science

Analytical HPLC Column Introduction

Hplchplc columns | introduction12,000psig pressure-rated columns , with sub 2 m media for high-efficiency, high-speed separationsVisionHT columns are optimized for high throughput and ultra high-pressure LC applications. Mechanically stable m media and ultra-low volume hardware delivers new separation benefits with excellent stability. A variety of phases Phases: C18, C10-B, C18-P, C18-HL, HILIC, SilicaSpecifications: Spherical silica, monomerically bonded, proprietary endcapping, 100, 120 pore sizeFormats: Ultra High-PressurePremium quality, exceptionally stable columns , without phase bleedAlltech Alltima HP phases are made from high purity silica to eliminate peak tailing.

hplc columns | introduction Directions for Using the Column Chart The chart lists the columns in descending order of hydrophobic capacity (H) . To find similar HPLC columns to test as back-up columns, follow these steps. 1) Find the column you are currently using and note neighboring columns which have similar (H) capacity factors.

Tags:

  Hplc, Analytical, Columns, Hplc analytical

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Analytical HPLC Column Introduction

1 Hplchplc columns | introduction12,000psig pressure-rated columns , with sub 2 m media for high-efficiency, high-speed separationsVisionHT columns are optimized for high throughput and ultra high-pressure LC applications. Mechanically stable m media and ultra-low volume hardware delivers new separation benefits with excellent stability. A variety of phases Phases: C18, C10-B, C18-P, C18-HL, HILIC, SilicaSpecifications: Spherical silica, monomerically bonded, proprietary endcapping, 100, 120 pore sizeFormats: Ultra High-PressurePremium quality, exceptionally stable columns , without phase bleedAlltech Alltima HP phases are made from high purity silica to eliminate peak tailing.

2 Proprietary bonding eliminates the problem of Column bleed for MS and ELSD detection. Full range of phases with pH stability from 1 to Phases: C18 for classic reversed-phase separations, EPS for extended polar selectivity, C18 HiLoad for extra reversed-phase retention, C18 Amide with low bleed, and : High purity spherical silica, mono-merically bonded, endcapped, 100, 120, 190 pore sizeFormats: Microbore, Expedite , Rocket , Solvent-Reducer, Analytical , PrepReversed-phase columns for use with 100% organic to 100% aqueous mobile phasesPrevail phases are designed for wettability with aqueous and organic mobile phases, and are especially useful for broad gradients.

3 Retain highly polar analytes with aqueous mobile phases as well as hydrophobic analytes in organic mobile Phases: Carbohydrate ES, Organic AcidSpecifications: Spherical silica, monomerically bonded, endcapped, 110 pore sizeFormats: Microbore, Expedite , Rocket , Solvent-Reducer, Analytical , PrepAnalytical hplc Column IntroductionGrace Key Column FamiliesSingle-Source Solution for Discovery to Recovery ApplicationsHPLC is commonly used in a wide range of applications, including drug discovery and purification for the pharmaceutical and biotechnology industries, environmental analysis, forensics, petrochemical analysis, food, cosmetics, and vitamins.

4 The combined premier product lines of Alltech , Davisil , Flexit , Grom , Jones Chromatography , Modcol , and Vydac create a single-source solution for hplc columns and accessories from discovery to Column families include reversed-phase, normal-phase, HILIC, ion-exchange, ion-exclusion, size-exclusion, and affinity stationary phases for small- and large-molecule separations, and our Column formats maximize their performance. Our product range includes standard and custom columns for Analytical separations, preparative phases for scale up, bulk packings that customers can pack in their own columns , and accessories to maintain separation ruggedness and help select the appropriate Column for your application, we describe key Column families and highlight unique phases within these families.

5 Whether the most important factor is analysis speed, Column bleed, pH stability, resolution, adjustable selectivity, or analyte molecular weight, Grace offers a Column to suit your application. 7110 Alltech Alltima HP ColumnsAlltech Prevail Columnsmore infoFor information about Grace Analytical hardware formats, see page infoFor information about prep columns , see pages 148 Families Suitable for Small Molecules (<2000 Molecular Weight)VisionHT Ultra High-Pressure Columns42000-01-24-signature 01 2008 catalog Grace proof 9 (rjh) november 5, 2007the henderson company 400 west erie, chicago illinois 60610 (312) 951-8973 f (312)

6 Hplchplc columns | introductionClassic reversed-phase and premium performance at an exceptional valueGraceSmart hplc phases use high purity silica. Which translates into symmetrical peaks for acids and bases, and predictable reversed-phase selectivity. Whether routine analysis or new method development, use individually tested GraceSmart columns to get premium performance at exceptional Phases: C18 Specifications: Spherical silica, monomerically bonded, endcapped, 120 pore sizeFormat: AnalyticalAlternate retention and selectivity for polar and nonpolar analytes available in sub 2 m particle sizesAlltech Platinum phases have a controlled polar silica surface which provides enhanced polar selectivity (EPS) in addition to reversed-phase retention.

7 C18 and EPS C18 columns are a complimentary duo to separate polar and nonpolar Phases: C18, EPS C18 Specifications: Spherical silica, monomerically bonded, proprietary endcapping, 100 pore sizeFormats: Microbore, Expedite , Rocket , Solvent-Reducer, Analytical , PrepAlltech Platinum ColumnsGraceSmart ColumnsNext generation Vydac media from the leader in peptide and protein separationsVydac MS columns provide unique selectivity and exceptional protein recovery. They require less TFA in the mobile phase for good peak shape, which increases microbore sensitivity of peptides and proteins by reducing quenching.

8 Vydac MS columns are also applicable to hydrophobic proteins and peptide Phases: C18, C8, C4 Specifications: Spherical silica, polymerically and monomerically bonded, endcapped, 300 pore sizeFormats: Capillary, Microbore, Expedite , Rocket , Solvent-Reducer, Analytical , PrepHigh-speed, high-efficiency columns for fast protein analysis Short 10 and 20mm ProZap columns with m particles provide high-speed protein and life science separations. Sharp, efficient peaks maximize method Phases: C18 Specifications: Sub 2 m spherical silica, proprietary bonding and endcapping, 500 pore sizeFormat: Expedite Vydac ProZap ColumnsFor peptide separations, peptide mapping and proteomics applicationsHigh-capacity Everest C18 columns are recommended as the first choice in peptide separations.

9 Everest offer high capacity to resolve complex samples such as protein Phases: C18 Specifications: Spherical silica, monomerically bonded, endcapped, 300 pore sizeFormats: Capillary, Microbore, Expedite , AnalyticalVydac Everest ColumnsA New Silica GenerationNew silica from Grace with high porosity surface and dense core ideal for scale-up applications. While high porosity surface increases mass transfer results in increased Column efficiencies and loading capacity, dense core and highly spherical shape yields mechanically robust Phases: C18, C8, and SilicaSpecifications: High purity spherical silica with high porosity surface and dense coreFormats.

10 Analytical , PrepGraceAlpha ColumnsColumn Families Suitable for Small Molecules (<2000 Molecular Weight) (continued) Column Families Suitable for Large Molecules (>2000 Molecular Weight)Vydac MS ColumnsAnalytical hplc Column Introduction42000-01-25-signature 01 2008 catalog Grace proof 9 (rjh) november 5, 2007the henderson company 400 west erie, chicago illinois 60610 (312) 951-8973 f (312) 951-610926analytical hplchplc columns | introductionDirections for Using the Column ChartThe chart lists the columns in descending order of hydrophobic capacity (H) . To find similar hplc columns to test as back-up columns , follow these ) Find the Column you are currently using and note neighboring columns which have similar (H) capacity ) Compare the values for interaction of polar compounds (A and C).