Example: dental hygienist

Appendix A: Communication Function Explanation A-1

Table of Contents1. Instruction and Model Explanation and Product Profile and Model Standard Special Special Auxiliary Special Data High Speed Installation and Dimension and Terminal PLC Mounting Arrangements and Wiring Notes . Wiring 4-145. Initial PLC Basic Application EX MPU and I/O Extension Troubleshooting and Fault Additional Special Devices and New Special M and D New Application 10-4 Appendix A: Communication Function B: EC Declaration of Always read this manual thoroughly before using DVP PLC. AC input power must be disconnected before anymaintenance. This is an OPEN-TYPE PLC. The PLC must be placed in an enclosure to meet the safety approval of IEC61131-2 and UL 508. The PLC should be kept in an enclosure away from high temperatures, humidity, vibration, corrosive gas, liquid, airborne dust and metallic debrise.

Table of Contents 1. Instruction and Inspections.....1-1 1.1. Model Explanation and Peripherals .....1-1

Tags:

  Explanation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Appendix A: Communication Function Explanation A-1

1 Table of Contents1. Instruction and Model Explanation and Product Profile and Model Standard Special Special Auxiliary Special Data High Speed Installation and Dimension and Terminal PLC Mounting Arrangements and Wiring Notes . Wiring 4-145. Initial PLC Basic Application EX MPU and I/O Extension Troubleshooting and Fault Additional Special Devices and New Special M and D New Application 10-4 Appendix A: Communication Function B: EC Declaration of Always read this manual thoroughly before using DVP PLC. AC input power must be disconnected before anymaintenance. This is an OPEN-TYPE PLC. The PLC must be placed in an enclosure to meet the safety approval of IEC61131-2 and UL 508. The PLC should be kept in an enclosure away from high temperatures, humidity, vibration, corrosive gas, liquid, airborne dust and metallic debrise.

2 Do not connect the AC main circuit power supply to any of the input/output terminals, as it will damage the PLC. Ensure all the wiring prior to power up. Disconnect all power. Wait one minute for capacitors to discharge before touching internal circuit. Some models are equipped with DC power supplyoutput, do not exceed its rated output power. Make sure the PLC is properly grounded , to avoidany electromagnetic Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS Model Explanation and PeripheralsThank you for choosing DELTA s PLC DVP Series. The DVP Series has main processing units and extension main processing units offer 14-60 points and the extension units offer 8-32 points. The maximum input/output can be extended up to 128 points. It also can be used on applications according to INPUT/OUTPUT points, power sources, output modules, digital/analog exchanges (A/D & D/A converter).

3 In addition, DVP SS Series has the special modules(AD/DA/PT/TC/XA) used for extending its functions and the maximum special modules can be extended up to 8 units. For more information on the DVP SS Series, refer to the DVP SS Series user ES/EX/SS MPU is made from improving the functions and specifications of R/T model structure. The additional R2/T2 model has wide improvement in commands type and execution speed. Please refer to the detail information about usable application commands and devices in this manual when using R2/T2 model. The specification in this manual is major for R2/T2 model so that there are some new commands and functions won t be provided for R/T model. Nameplate ModelInput Power Supply SpecificationOutput Module SpecificationControl Code and Serial NumberMCU Version Serial Number ExplanationProduction numberProduction weekProduction year 2003 Production factory (TaoYuan Plant)Version typeProduction model1.

4 Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED1-2 Model ExplanationDVP200 H TYPE01 L TYPE11 H TYPEP roduct Series: DVP SeriesInputs+Outputs points / unit: 08~60pointsModelsE : Main Processing Unit (Base Unit)X : Extension UnitS : S-TYPE Main Processing UnitModel TypesS : StandardX : A/D, D/A FunctionsC : InextensibleM : Digital Input (X input extend)N : Digital Output (Y output extend)P : Digital Input/Output (X/Y extend)2 : Upgrade ModelR : RelayT : TransistorN : No Output ModuleAC InputDC InputDC Input PeripheralEquipment DVPHPP: Handheld Programming Panel WPLSoft: Windows Ladder Logic Programming Software DPLSoft: DOS Ladder Logic Programming Software DVPACAB115: Cable (HPP PLC, DVPHPP has this cable attached) DVPACAB215: Cable (PC(9 PIN & 25 PIN D-SUB) PLC) DVPACAB230.

5 3M Cable (PC (9 PIN & 25 PIN D-SUB) PLC) DVPACAB2A30: 3M Cable (PC (9 PIN D-SUB) PLC) DVPACAB230: 3M Cable (PC PLC) DVPACAB315: Cable (HPP PC) DVPACAB403: 30cm Cable (MPU-main processing unit Extension Unit or Extension Unit Extension Unit I/O signalextension cable) DVPAADP01: HPP Power Supply (DVPACAB315 is attached)1. Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS Product Profile and OutlineFig. 1-1: Features of the DVP PLC1 DIN rail clip9 Output indicators2 DIN rail (35mm)10 Status indicators, POWER, RUN ERROR3 Direct mounting holes11I/O terminal cover4 Programming port cover(RS-232)12I/O terminal cover5 Extension port13I/O terminal nameplate panel6I/O terminals14I/O terminal nameplate panel7I/O terminals15RS-485 Communication port8 Input indicators1.

6 Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS Model Numbers Standard MPU-00 Input / OutputInput UnitOutput UnitModelPowerPointTypePointTypeProfileP rofile referenceDVP14ES00R286nDVP24ES00R2168 DVP32ES00R21616oDVP60ES00R23624 RelayrDVP14ES00T286nDVP24ES00T2168 DVP32ES00T21616oDVP60ES00T2100~240 VAC36DC SinkorSource24 Transistorrno Standard MPU-01 Input / OutputInput UnitOutput UnitModelPowerPointTypePointTypeProfileD VP14ES01R286pDVP24ES01R2168 DVP32ES01R21616 RelayqpqDVP14ES01T286pDVP24ES01T2168 DVP32ES01T224 VDC16DC SinkorSource16 Transistorq1. Sink or Source connections. Please refer to Chapter 4 Installation and Please refer to Chapter 2 Standard Specifications for detailed electrical Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED1-5 Special Function MPU 00 Input / OutputInput UnitOutput UnitPointTypePointTypeModelPowerDIAIDIAI DOAODOAOP rofile referenceDVP20E X00R28462 RelayDVP20E X00T2100~240 VAC84DC SinkorSource-20mA~20mA-10V ~ +10 V62 Transistor0~20mAor-10V ~ +10 V(for R/T model)0V ~ +10 V(for R2/T2 model) Analog/Digital MPU 11 Input / OutputInput UnitOutput UnitPointTypePointTypeModelPowerDIAIDIAI DOAODOAOP rofile referenceDVP20E X11R28462 RelayDVP20E X11T224 VDC84DC SinkorSource-20mA~20mA-10V ~ +10 V62 Transistor0~20mA0V ~ +10 VDI Digital Input DO Digital Output AI Analog Input AO Analog Output 1.

7 Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED1-6 Module Standard MPU 11 Input / OutputInput UnitOutput UnitModelPowerPointTypePointTypeProfile referenceDVP14SS11R286 DVP14SS11T2100~240 VAC8DC SinkorSource6 RelayTransistor Digital I/O Extension Unit-00 Input / OutputInput UnitOutput UnitModelPowerPointTypePointTypeProfile referenceDVP24XN00R024 DVP24XP00R168 DVP32XP00R1616 RelayDVP24XP00T168 DVP24XN00T024 DVP32XP00T100~240 VAC16DC SinkorSource16 Transistor1. Sink or Source connections. Please refer to Chapter 4 Installation and Please refer to Chapter 2 Standard Specifications for detailed electrical Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED1-7 Digital I/O Extension 01 (L-Type)Input UnitOutput UnitModelPowerPointTypePointTypeProfile referenceDVP16XM 01N160 NonenDVP16XN01R016 DVP24XN01R024 DVP24XP01R168 DVP32XP01R1616 RelaynDVP16XN01T016 DVP24XN01T024 DVP24XP01T168 DVP32XP01T24 VDC16DC or Source connections.

8 Please refer to Chapter 4 Installation and refer to Chapter 2 Standard Specifications for detailed electrical Introduction and Inspections DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED1-8 Digital I/O Extension 11 (H-Type)Input UnitOutput UnitModelPowerPointTypePointTypeProfile referenceDVP08XM11N80nDVP16XM 11N160 NoneoDVP08XN11R08nDVP16XN11R016 DVP24XN11R024pDVP08XP11R44nDVP24XP11R168 nDVP32XP11R1616 RelaypDVP08XN11T08nDVP16XN11T016 DVP24XN11T024pDVP08XP11T44nDVP24XP11T168 DVP32XP11T24 VDC16DC SinkorSource16 Transistorpop1. Sink or Source connections. Refer to Chapter 4 Installation and Wiring for more Refer to Chapter 2 Standard Specifications for detailed electrical When connects to DVP08XP11R/T, recommend to place at the end of extension units. Refer to Chapter 8 EX MPU and I/O Extension Units for more Introduction and Inspections DELTA ELECTRONICS, INC.

9 ALL RIGHTS RESERVED1-9 Digital I/O Extension UnitsInput UnitOutput UnitModelPowerPointTypePointTypeProfile referenceDVP08SM 11N80 NoneDVP08SN11R08 RelayDVP08SN11T08 TransistorDVP08SP11R44 DVP16SP11R88 RelayDVP08SP11T44 DVP16SP11T24 VDC8DC SinkorSource8 Transistor Please refer to each user manual of extension model for the detail of SS special extension module. Power Output ModuleModelInput PowerOutput PowerProfile referenceDVPPS01100~240 VAC 50/60Hz Output Voltage: 24 VDCMax. Output Current: 1A2. Standard Specifications DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED2-1 General SpecificationsItemsSpecificationsRemarks Control MethodStored program, cyclic scan systemI/O Processing MethodBatch I/O (refresh)Direct I/O instruction availableExecution SpeedBasic commands (several s)Application commands (10~hundreds s)Program LanguageLadderLogic, Instruction, SFCI ncluding the Step commandsProgram Capacity3792 STEPSB uilt-in EEPROMI nstructions32 Basic sequential commands (Including STL / RET)97 Application commands (145 including the 32-bit commands)General512+232 PointsM000~M511+ M768~M999 Latched256 PointsM512~M767 Auxiliary RelaysSpecial280 PointsM1000~M1279 Initial Step Point10 PointsS0~S9 Step Relays (Latched)General Step Point118 PointsS10~S12764 PointsT0~T63 (100ms time base)63 PointsT64~T126 (10ms time base, when M1028 is ON)

10 TimersDigital1 PointsT127 (1ms time base)General112 PointsC0~C111 (16-bit counters)Latched16 PointsC112~C127 (16-bit counters)CountersHigh-speed13 Points 1-Phase 5 KHz, 2-Phase 5 KHzC235~C254 (all latched type, 32-bit counters)General408 PointsD0 ~ D407 Latched192 PointsD408~D599 Data registersSpecial312 PointsD1000~D1311A D4 Analog Input Channels10-bit resolution (EX MPU only)Digital /AnalogD A2 Analog Ou tput Channels8-bit resolution (EX MPU only)High Speed Pulse Output2 point (Y0, Y1), pulse output frequency: 10Hz to 10 KHzPointers/InterruptP / IP : 64 Points / I : 4 PointsP0~P63 / I001, I101,I201, I301 Index RegisterE / F2 PointsE (=D1028), F (=D1029)Decimal K16-bit: -32768~+3276732-bit: -2147483648~+2147483647 ConstantsHexadecimal H16-bit: 0000~FFFF32-bit: 00000000~FFFFFFFFS erial CommunicationRS-232, RS-485 (2 Ports)Protection FeaturesPassword, Execution Time, Illegitimate Command or OperandMonitor / DebugExecution time, Device setting2.