Example: quiz answers

Applications Absolute Maximum Ratings - Vicor …

mini Family 110V Input Actual size: x x S. [57,9 x 55,9 x 12,7mm]. C US C NRTL US. DC-DC Converter Module Features & Benefits Applications DC input range: 66 154V (continuous) Railway/Transportation system Applications including communications systems, Isolated input information display, lighting, control systems, ticket machines, passenger entertainment, public address systems, door control, industrial power systems and power Encapsulated circuitry for shock and generation systems. vibration resistance Extended temperature range For details on proper operation please refer to the: ( 55 to +100 C) Design Guide & Applications Manual for Maxi, mini , Micro Family. Input surge withstand: 250V for 100ms DC output: 48V. Absolute Maximum Ratings Programmable output: 10 110%.

110V Mini Family Rev 3.7 Page 2 of 14 05/2018 110V Input ParameterMinTypMax Notes Unit Operating input voltage 66 110 154 V DC Per …

Tags:

  Applications, Mini

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Applications Absolute Maximum Ratings - Vicor …

1 mini Family 110V Input Actual size: x x S. [57,9 x 55,9 x 12,7mm]. C US C NRTL US. DC-DC Converter Module Features & Benefits Applications DC input range: 66 154V (continuous) Railway/Transportation system Applications including communications systems, Isolated input information display, lighting, control systems, ticket machines, passenger entertainment, public address systems, door control, industrial power systems and power Encapsulated circuitry for shock and generation systems. vibration resistance Extended temperature range For details on proper operation please refer to the: ( 55 to +100 C) Design Guide & Applications Manual for Maxi, mini , Micro Family. Input surge withstand: 250V for 100ms DC output: 48V. Absolute Maximum Ratings Programmable output: 10 110%.

2 Regulation: no load to full load Parameter Rating Unit Notes Efficiency: Up to 90%. +IN to IN voltage to +260 VDC Maximum operating temp: 100 C, full load PC to IN voltage to + VDC Power density: up to 80W per cubic inch PR to IN voltage to + VDC. Height above board: [10,9mm] SC to OUT voltage to + VDC. Parallelable, with N+M fault tolerance Sense to OUT voltage VDC. Low noise ZCS/ZVS architecture Isolation voltage IN to OUT 3000 VRMS Test voltage RoHS Compliant (with F or G pin option). IN to base 1500 VRMS Test voltage OUT to base 500 VRMS Test voltage Product Overview Operating Temperature 55 to +100 C M-Grade These DC-DC converter modules use Storage Temperature 65 to +125 C M-Grade advanced power processing, control and packaging technologies to provide the 500 [260] F [ C] <5sec; wave solder Pin soldering temperature performance, flexibility, reliability and cost 750 [390] F [ C] <7sec; hand solder effectiveness of a mature power component.

3 Mounting torque 5 [ ] in lbs [ ] . 6 each High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Part Numbering V110B24C200BL V1 1 0 B B. Product Type Product Grade Temperatures ( C) Output Power Pin Style Finish Baseplate Output Voltage rade Operating G Storage VOUT POUT Blank: Short Tin/Lead Blank: Slotted V = Standard 3V3 = 2: Threaded S = Enhanced E = 10 to +100 20 to +125 75W, 100W L: Long Tin/Lead 5 = 5V C = 20 to +100 40 to +125 5V 100W, 150W S: Short ModuMate Gold 3: Through-hole efficiency (avail. 12 8 = 8V T = 40 to +100 40 to +125 8V 150W N: Long ModuMate Gold VOUT only) 12 = 12V H = 40 to +100 55 to +125 12V 150W, 200W F: Short RoHS Gold M = 55 to +100 65 to +125 15V 150W, 200W G: Long RoHS Gold 15 = 15V 24V 150W, 200W K: Extra Long RoHS Gold 24 = 24V 28V 150W, 200W.

4 28 = 28V 36V 150W, 200W. 36 = 36V 48V 150W, 200W. 48 = 48V. 110V mini Family Rev Page 1 of 14 05/2018. 110V Input Module Family Electrical Characteristics Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. MODULE INPUT SPECIFICATIONS. Parameter Min Typ Max Unit Notes Operating input voltage 66 110 154 VDC Per EN50155 and GBT-25119. Input surge withstand 250 VDC <100ms Undervoltage turn-on 64 VDC. Undervoltage turn-off 54 56 VDC. Overvoltage turn-off/on VDC. Disabled input current mA PC pin low MODULE OUTPUT SPECIFICATIONS. Parameter Min Typ Max Unit Notes Output voltage setpoint 1 % Of nominal output voltage.

5 Nominal input; full load; 25 C. Line regulation % Low line to high line; full load Temperature regulation % / C Over operating temperature range Power sharing accuracy 2 5 % 10 to 100% of full load Of nominal output voltage. For trimming below 90%. Programming range 10 110 % of nominal, a minimum load of 10% of Maximum rated power may be required. +OUT to OUT, +Sense to OUT Absolute Maximum Ratings to VDC Externally applied 5V to VDC Externally applied 8V to VDC Externally applied 12V to VDC Externally applied 15V to VDC Externally applied 24V to VDC Externally applied 28V to VDC Externally applied 36V to VDC Externally applied 48V to VDC Externally applied Note: The permissible load current must never be exceeded during normal, abnormal or test conditions.

6 For additional output related application information, please refer to output connections on page 9. THERMAL RESISTANCE AND CAPACITY. Parameter Min Typ Max Unit Baseplate to sink; flat, greased surface C/Watt Baseplate to sink; thermal pad (P/N 20264) C/Watt Baseplate to ambient C/Watt Baseplate to ambient; 1000 LFM C/Watt Thermal capacity 83 Watt-sec/ C. 110V mini Family Rev Page 2 of 14 05/2018. 110V Input Module Family Electrical Characteristics (Cont.). MODULE CONTROL SPECIFICATIONS. Parameter Min Typ Max Unit Notes Primary Side (PC = Primary Control; PR = Parallel). PC bias voltage VDC PC current = During normal operation current limit mA PC voltage = PC module disable VDC Switch must be able to sink 4mA. See Fig. 2. PC module enable delay 4 7 ms PC module alarm Vavg UV, OV, OT, module fault.

7 See Figs. 3 and 5. PC resistance M See Fig. 3, converter off or fault mode PR emitter amplitude Volts PR load >30 , <30pF. PR emitter current 150 mA PR receiver impedance 375 500 625 25 C. PR receiver threshold Volts Minimum pulse width: 20ns PR drive capability 12 modules Without PR buffer amplifier Secondary Side (SC = Secondary Control). SC bandgap voltage VDC Referenced to Sense SC resistance 990 1000 1010 SC capacitance F SC module alarm 0 VDC With open trim; referenced to Sense. See Fig. 7. MODULE GENERAL SPECIFICATIONS. Parameter Min Typ Max Unit Notes Remote sense (total drop) VDC per leg (sense leads must be connected to respective, output terminals). Isolation test voltage (IN to OUT)* 3000 VRMS Complies with reinforced insulation requirements Isolation test voltage (IN to base)* 1500 VRMS Complies with basic insulation requirements Isolation test voltage (OUT to base)* 500 VRMS Complies with operational insulation requirements Isolation resistance 10 M IN to OUT, IN to baseplate, OUT to baseplate ounces Weight (E, C, T grade).

8 [ ] [ ] [ ] [grams]. ounces Weight (H, M grade). [ ] [ ] [ ] [grams]. Temperature limiting 100 115 C See Figs. 3 and 5. Do not operate coverter >100 C. UL60950-1, EN60950-1, CSA60950-1, IEC60950-1. Agency approvals cURus, cT Vus, CE. With appropriate fuse in series with the +Input * Isolation test voltage, 1 minute or less. Note: Specifications are subject to change without notice. 110V mini Family Rev Page 3 of 14 05/2018. 110V Input MODULE-SPECIFIC OPERATING SPECIFICATIONS. , 100W ( S110B3V3C100BL, V110B3V3C100BL). Parameter Min Typ Max Unit Notes Efficiency S110B3V3C100BL (enhanced efficiency) % Nominal input; full load; 25 C. V110B3V3C100BL (standard efficiency) Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint Volts 25 C; recycle input voltage or PC to restart (>100ms off).

9 Dissipation, standby Watts No load Load regulation % No load to full load; nominal input Load current 0 Amps Current limit 41 Amps Output voltage 95% of nominal Short circuit current 41 Amps Output voltage <250mV. , 75W ( S110B3V3C75BL, V110B3V3C75BL). Parameter Min Typ Max Unit Notes Efficiency S110B3V3C75BL (enhanced efficiency) % Nominal input; full load; 25 C. V110B3V3C75BL (standard efficiency) Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint Volts 25 C; recycle input voltage or PC to restart (>100ms off). Dissipation, standby Watts No load Load regulation % No load to full load; nominal input Load current 0 Amps Current limit Amps Output voltage 95% of nominal Short circuit current Amps Output voltage <250mV 5 VOUT, 150W ( S110B5C150BL, V110B5C150BL).

10 Parameter Min Typ Max Unit Notes Efficiency S110B5C150BL (enhanced efficiency) % Nominal input; full load; 25 C. V110B5C150BL (standard efficiency) Ripple and noise 85 107 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint Volts 25 C; recycle input voltage or PC to restart (>100ms off). Dissipation, standby Watts No load Load regulation % No load to full load; nominal input Load current 0 30 Amps Current limit Amps Output voltage 95% of nominal Short circuit current 21 Amps Output voltage <250mV 5 VOUT, 100W ( S110B5C100BL, V110B5C100BL). Parameter Min Typ Max Unit Notes Efficiency S110B5C100BL (enhanced efficiency) % Nominal input; full load; 25 C. V110B5C100BL (standard efficiency) Ripple and noise 240 300 mV p-p; Nominal input; full load; 20 MHz bandwidth Output OVP setpoint Volts 25 C; recycle input voltage or PC to restart (>100ms off).