Transcription of ARCHITECTURAL DRAWINGS - Monier
1 ARCHITECTURAL DRAWINGSUSE OF ARCHITECTURAL DRAWINGS INDEX OF DRAWINGS BY DETAIL NUMBER GENERAL DETAILS B26 Product technical Data 3B27 Minimum Pitch Table 3B28 Rafter Length Table 4MT01 Sarked Ceiling - Exposed Rafters 4MT25 Fire Wall Detail 5 RIDGE DETAILS B12 Ridge Detail 5B13 Roof/Wall Ridge - Detail/Clerestorey 6MT02 Steep Pitched Ridge 6MT03 Butt Jointed Ridge 7 MT04 Flexible Pointing 7 BARGE DETAILS B05 Barge Tile Detail 8B06 Bed & Point Finish 8B07 Small Panel Metal Detail 9MT05 Barge Detail With Secret Gutter - Flat Tile 9MT06 Verge - Secret Gutter 10MT07 Verge - No Overhang Scribed Fillet 10MT08 Verge - No Overhang Concrete Block 11MT09 Flashing At Junction Of Metal Roof & Tile 11MT11 Barge Detail With Z Flashing - Flat Tile 12MT12 Barge Detail With Banbury Flashing - Flat Tile 12B30 Bed & Point Finish - Flat Tile 13 APRON DETAILS B01 Apron Details - Parallel Flashing Without Underlay 14B02 Apron Details - Parallel Flashing With Underlay 14B03 Apron Details - Transverse Flashing Without Underlay 15B04 Apron Details - Transverse Flashing With Underlay 15B25 Spreader For Roof Discharge 16B29 Kickout Flashing 16MT13 Stepped Cover Flashing 17MT14 Flashing To Brick Abutment 17MT15 Dutch Gable Detail 18MT16 Vertical Tiling 18 PITCH CHANGE DETAILS B08 Change In Pitch -35 Degrees Or Less 19B09 Change In Pitch - Greater Than 35 Degrees 19MT10 Mansard Detail 20 EAVES DETAILS B19 Timber Fascia Eaves Detail - Without Underlay 20B20 Timber Fascia Eaves Detail - With Underlay 21B21 Internal Fascia Gutter Detail 21B22 External Fascia Gutter Detail 22B23 Eaves Exposed Rafters 22B24 Eaves & Rafter Detail With Sarking 23MT23 Eaves Standard Gutter 23MT24 Fascia
2 Height 24 VALLEY DETAILS B10 Valley Detail Without Underlay 24B11 Valley Detail With Underlay 25MT21 Hip Gutter 25MT22 Steep Pitch Roof Valley 26 PENETRATION DETAILS B14 Plan View Of Three Sided Penetration 26B15 Abutment Detail For Framed Penetration 27B16 Elevation/Section View Of Three Sided Penetration 27B17 Cross Section Of Hidden Gutter 28B18 Pipe Penetration Detail 28MT17 Cross Section Hidden Gutter - Flat Tile 29MT18 Chimney Tray 29MT19 Chimney Flashing 30MT20 Pipe Penetration Detail - Flat Tile 30 CONTENTS1 ARCHITECTURAL DRAWINGSUSE OF ARCHITECTURAL DRAWINGSM onier roofing systems provide contemporary and innovative design solutions that benefit from the time proven effectiveness and sustainability of tiles. This manual contains a broad range of roofing details and applications enabling architects and specifiers to easily access and assess the suitability of design for their DETAIL DRAWINGS NOW ONLINEM onier roofing detail DRAWINGS are available in multiple CAD formats and as enlarged PDF files at information provided in the DRAWINGS provide reference information on the typical use of the Monier product.
3 The information provided in this reference guide is generic innature; it does not contain the full details required for construction, nor does it constitute an express statement as to fitness for a particular purpose. Professional advice is required to take into account all site and design specific influences. Designers and specifiers will typically provide details specific to particular projects: these should always be referred to in preference to the default systemof DRAWINGS . The instructions and detailsavailable refer to both concrete and terracotta tiles (except where specifically noted). Monier COMPLIANCE WITH THENEW ZEALAND BUILDING CODEWhen installed according to the manufacturers instructions, Monier products will meet theDurability performance requirements of NZBC B2 and used for verifying compliance with the relevant performances of the New ZealandBuilding Code, include testing and assessment by a laboratory, ease of installation assessment, assessment of data provided bythe manufacturer and the inservice history overseas and in New Zealand.
4 Details areavailable from INFORMATION FORSPECIFICATION, PREPARATION& INSTALLATIONThis manual has been prepared by Monier to assists the architect, builder and installer to specify, prepare and install roof it is not possible to detail every condition that may be encountered, Monier will assist to advise on any special situationsthat may manual has been written as a working guide for industry, however it is not intended to replace good trade practice and experience essential to obtaining a quality roof installation. Nor does this manual overridespecific advice received from Monier fixing and specifiers should ensure that the details provided in this manual are followed and determined to their ownsatisfaction that the job is complete to an acceptable standard of trade practice. Allcare has been taken in the compilation of this manual.
5 However, Monier accepts noresponsibility or liability for the contents of the manual (including any printing or typographical errors) and recommends that all standards and recommendations are independently information contained in this manual is correct at the time of creation, specifications are subject to change without information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specificapplication. Nothing in this information constitutes a statement of fitness for particularpurpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non- Monier products. 2010 The copyright of this document is the property of CSR Building Products (NZ) Ltd trading as Monier and shall not be reproduced, copied, loaned or disposed of directly, or indirectly.
6 Nor used for any purpose other than that for which it is specifically furnished without prior ARCHITECTURAL DRAWINGSSECTION 8 2 INDEX OF DRAWINGS BY DETAIL NUMBERD etail Category PageB01 Apron Details - Parallel Flashing Without Underlay Apron Details 14B02 Apron Details - Parallel Flashing With Underlay Apron Details 14B03 Apron Details - Transverse Flashing Without Underlay Apron Details 15B04 Apron Details - Transverse Flashing With Underlay Apron Details 15B05 Barge Tile Detail Barge Details 8B06 Bed & Point Finish Barge Details 8B07 Small Panel Metal Detail Barge Details 9B08 Change In Pitch - 35 degrees Or Less Pitch Change Details 19B09 Change In Pitch - Greater Than 35 Degrees Pitch Change Details 19B10 Valley Detail Without Underlay Valley Details 24B11 Valley Detail With Underlay Valley Details 25B12 Ridge Detail Ridge Details 5B13 Roof/Wall Ridge - Detail/Clerestorey Ridge Details 6B14 Plan View Of Three Sided Penetration Penetration Details 26B15 Abutment Detail For Framed Penetration Penetration Details 27B16 Elevation/Section View Of Three Sided Penetration Penetration Details 27B17 Cross Section Of Hidden Gutter Penetration Details 28B18 Pipe Penetration Detail Penetration Details 28B19 Timber Fascia Eaves Detail - Without Underlay Eaves Details 20B20 Timber Fascia Eaves Detail - With Underlay Eaves Details 21B21 Internal Fascia Gutter Detail Eaves Details 21B22 External Fascia Gutter Detail Eaves Details 22B23 Eaves Exposed Rafters Eaves Details 22B24 Eaves & Rafter Detail With Sarking Eaves Details 23B25 Spreader For Roof Discharge Apron Details 16B26 Product
7 technical Data General Details 3B27 Minimum Pitch Table General Details 3B28 Rafter Length Table General Details 4B29 Kickout Flashing Apron Details 16B30 Bed & Point Finish - Flat Tile BargeDetails 13MT01 Sarked Ceiling - Exposed Rafters General Details 4MT02 Steep Pitched Ridge Ridge Details 6MT03 Butt Jointed Ridge Ridge Details 7MT04 Flexible Pointing Ridge Details 7MT05 Barge Detail With Secret Gutter - Flat Tile Barge Details 9MT06 Verge - Secret Gutter Barge Details 10MT07 Verge - No Overhang Scribed Fillet Barge Details 10MT08 Verge - No Overhang Concrete Block Barge Details 11MT09 Flashing At Junction Of Metal Roof & Tile Barge Details 11MT10 Mansard Detail Pitch Change Details 20MT11 Barge Detail With Z Flashing - Flat Tile Barge Details 12MT12 Barge Detail With Banbury Flashing - Flat Tile Barge Details 12MT13 Stepped Cover Flashing Apron Details 17MT14 Flashing To Brick Abutment Apron Details 17MT15 Dutch Gable Detail Apron Details 18MT16 Vertical Tiling Apron Details 18MT17 Cross Section Hidden Gutter - Flat Tile Penetration Details 29MT18 Chimney Tray Penetration Details 29MT19 Chimney Flashing Penetration Details 30MT20 Pipe Penetration Detail - Flat Tile Penetration Details 30MT21 Hip Gutter Valley Details 25MT22 Steep Pitch Roof Valley Valley Details 26MT23 Eaves Standard Gutter Eaves Details 23MT24 Fascia Height Eaves Details 24MT25 Fire Wall Detail General Details 5 ARCHITECTURAL DRAWINGS3 NOT TO SCALE.
8 ALL technical FILES IN THIS MANUAL ARE SUBJECT TO OUR DISCLAIMER - SEE PAGE Pitches for Concrete & Clay TilesTile MaterialProfile TypeWith Underlay (Refer NoteWithout UnderlayConcrete TilesType I*15 20 Type II20 -Type III25 -Clay TilesType I20 25 Type II20 -Type III25 -* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile IType 1: Double tiles having two distinct watercourses with a minimum watercourse depth of IISingle profile tiles having one watercourse a minimum of 25mm in heightType IIIT iles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakesand Pitches for Concrete & Clay TilesTile MaterialProfile TypeWith Underlay (Refer NoteWithout UnderlayConcrete TilesType I*15 20 Type II20 -Type III25 -Clay TilesType I20 25 Type II20 -Type III25 -* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile IType 1.))
9 Double tiles having two distinct watercourses with a minimum watercourse depth of IISingle profile tiles having one watercourse a minimum of 25mm in heightType IIIT iles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakesand Pitches for Concrete & Clay TilesTile MaterialProfile TypeWith Underlay (Refer NoteWithout UnderlayConcrete TilesType I*15 20 Type II20 -Type III25 -Clay TilesType I20 25 Type II20 -Type III25 -* Monier Hacienda & Villa profile concrete roof tiles conform to the "Type 1" profile IType 1: Double tiles having two distinct watercourses with a minimum watercourse depth of IISingle profile tiles having one watercourse a minimum of 25mm in heightType IIIT iles not fitting the Type I or Type II categories, and includes flat tiles and those resembling slated, shakesand shingles.)
10 * Monier Hacienda profile concrete roof tiles conform to the "Type I" profile type.** Monier Horizon, Georgian, Madison profile concrete roof tiles conform to the Type III profile DETAILS Horizon, Georgian,Madison Profile Roof TileHacienda Profile Roof TileRidge TileTapered Barge TileValley Tray20mm20mmMonier Concrete Roofing Tiles are manufactured in accordance withNZS 4206: 1992 'Concrete Interlocking Roofing Tiles' TileMonier RoofingPO Box 188,Takanini,Auckland This information is intended solely as a guide for use of Monier products. Before using Monier products you should ensure that the product is suitable for use in the specific application. Nothing in this information constitutes a statement of fitness forparticular purpose - appropriate expert advice should always be obtained. Monier makes no warranty regarding the use of this information with non- Monier products.