And Variable DisplacementPFB 5, PFB 10, PFB 20 PVB 5/6, PVB 10/15, PVB 20/29, PVB 45 and PVB 90 to SAEPVB 5/6, PVB 10/15, PVB 20/29 to DIN/ISO 3019, Part 2GB-2379 BAxial Piston Pumps Vickers Piston .. General .. Functional .. Model .. Operating .. Minimum Inlet pressure .. Performance data @ 1500 r/min drive speed:PFB5, PFB10, .. PVB5, PVB6, .. PVB15, PVB20, .. PVB45, .. Performance data @ 1800 r/min drive speed:PFB5, PFB10, .. PVB5, PVB6, .. PVB15, PVB20, .. PVB45, .. control data for PVB .. Noise .. Installation dataPFB5 SAE flange .. PFB10 SAE flange .. PFB20 SAE flange .. PVB5/6 SAE flange mounting C & CM pressure compensator.

Mounting flange M = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Omit for SAE mounting flange Shaft rotation Viewed at shaft end R = Clockwise L = Anticlockwise (not avalable for PFB10 and PFB20) Displacement zone PVB models only. S = One side of center (pressure compensated models only) D = Both sides of center (Handwheel

Tags:

  Control, Pressure, Flange

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Axial Piston Pumps - Advanced Motion Controls

1 And Variable DisplacementPFB 5, PFB 10, PFB 20 PVB 5/6, PVB 10/15, PVB 20/29, PVB 45 and PVB 90 to SAEPVB 5/6, PVB 10/15, PVB 20/29 to DIN/ISO 3019, Part 2GB-2379 BAxial Piston Pumps Vickers Piston .. General .. Functional .. Model .. Operating .. Minimum Inlet pressure .. Performance data @ 1500 r/min drive speed:PFB5, PFB10, .. PVB5, PVB6, .. PVB15, PVB20, .. PVB45, .. Performance data @ 1800 r/min drive speed:PFB5, PFB10, .. PVB5, PVB6, .. PVB15, PVB20, .. PVB45, .. control data for PVB .. Noise .. Installation dataPFB5 SAE flange .. PFB10 SAE flange .. PFB20 SAE flange .. PVB5/6 SAE flange mounting C & CM pressure compensator.

2 PVB5/6 side ported thru .. PVB10/15 SAE flange mounting C & CM pressure compensator .. PVB10/15 side ported thru .. PVB5/6 & PVB10/15 M lever control , & H handwheel .. PVB20/29 SAE flange mounting C & CM pressure compensator .. PVB20/29 side ported thru .. PVB45 flanged .. PVB45 foot .. PVB5/6, PVB10/15 & PVB20/29 CC & CMC pressure compensator and adjustable maximum displacement .. PVB5 29 CG Remote control compensator, CVP Load sensing & S30 drain port option .. PVB5/6, PVB10/15, PVB20/29 DIN/ISO .. Installation .. CharacteristicsTypeAxial Piston Pumps .. Operating pressureup to 210 bar.. (3000 psi)Displacement10,5 to 197,5 cm3/r.

3 ( to 12 in3/r)Drive speedup to 3600 r/min.. General DescriptionBoth fixed and variable displacementmodels make up this range of axialpiston Pumps . Their high performanceratings and efficiencies are achievedwith a variety of hydraulic fluids. Fixeddisplacement models are noted for theirvolumetric and mechanical displacement models canclosely match pressure and/or flowdemand with a control selected from: pressure compensator with or without a remote control facility. pressure compensator with adjustable displacement control . Load sensing compensator. Mechanical (lever) control . Handwheel controlTypical SectionVariable displacement model with compensator control C or CM Functional SymbolsPFBF ixed displacementmodelsWith handwheel,or pressurecompensator (C or CM)(simplified symbol)With CVP load sensingand pressure limiterPVBV ariable displacementmodelsWith pressure compensatorarranged for remote controlC(M)G (detailed symbol) CodesBasic modelsF= Fixed displacement typeV= Variable displacement typeDisplacementPFB and PVB models:5 = 10,55 cm3/r ( in3/r)10 = 21,10 cm3/r ( in3/r)20 = 42,80 cm3/r ( in3/r)PVB models only.

4 6 = 13,81 cm3/r ( in3/r)15 = 33,00 cm3/r ( in3/r)29 = 61,60 cm3/r ( in3/r)45 = 94,50 cm3/r ( in3/r)90 = 197,50 cm3/r ( in3/r)Foot mounting optionF = Foot mounting option for PVB45 andPVB90 for flange For foot mounting brackets. forother models see bottom of flange M = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Omit for SAE mounting flangeShaft rotationViewed at shaft endR= ClockwiseL= Anticlockwise (not avalable for PFB10 and PFB20)Displacement zonePVB models One side of center ( pressure compensated models only)D= Both sides of center (Handwheel and lever controlled models only)Omit for PFB main portsF= PVB45 and PVB90 models for P*B5 to 29 shaft optionPVB5 to 29 only.

5 X= Thru shaft (with side entry ports)Omit for PVB45 and PVB 90, or if ** (F) (M) *(C)-(G) (L)132414511234567*B-*67(*)8-**9-**10--1 2-13- ** - **16 Shaft typeN= Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1Y= SAE models P*B5 to 15 for 20 thru 90 modelsPump design number10 = PFB2030 = PFB1031 = PVB10 and PVB1520 = all other modelsDisplacement control optionsPVB models pressure compensator. Pressureadjustment range:PVB90: 19 to 210 bar (275 to 3000 psi)All other models: 17 to 210 bar (250 to 3000 psi)Also used as prefix for itemNote. For PVB6, 15 and 29 models, theuser must ensure that the max. pressuresetting never exceeds 140 or 100 bar(2000 or 1500 psi) dependent on thetype of fluid being = pressure compensator.

6 Option for all sizes except adjustment range:PVB45: 10 to 100 bar (150 to 1500 psi)All other sizes: (17 to 100 bar (250 to 1500 psi)CVP = Load sensing with pressure to 15 only:H= Handwheel controlM= Lever controlV= No control (As for M type but without lever.)Omit for PFB displacementadjustmentPVB5 to 29 models only:C= C or CM compensator, and with Omit when not compensator variationsPVB5 to 29 models only:G= Remotely adjustable pressure when not locationPVB5 to 15 models with H , M or V Controls only:L= Left hand, when viewed at shaft for right hand, or when a pressurecompensator is design numberPVB models = H and M Controls ;also C control for PVB9011 = C and CM = CVP = CG design optionsFor PFB5 and PVB5 to 29 only.)

7 = Extra drain port to permit vertical shaft-up PVB5 to PVB29 pressurecompensated models only:GE1 = 10% minimum displacement. when pressure all models:GEVS= pressure setting knob with key when not bracket mounting kitsOrder separately if required. Kits includepump fixing pump sizes:code numberFB-A-10 422582 P*B5/6FB-B-10 422583 P*B10/15 and PFB20FB-C-10 422584 PVB20/29121213141516(F)8(X) DataPressure and Speed LimitsBasic modelGeometricMaximum shaftMaximum outletdesignationdispalcement,speed (r/min) pressure , bar (psi)cm3/r (in3/r) Anti-wearWater-in Water-Anti wearWater Water-in hydraulicoilglycolhydraulicglycoloiloile mulsionoilemulsion(40%/60%)(40%/60%)PFB5 10,55 ( )3600210 (3000)PFB1021,10 ( )320018001800210 (3000)175 (2500)175 (2500)PFB2042,80 ( )2400175(2500)PVB510,55 ( )210 (3000)140 (2000)140 (2000)PVB613,81 ( )140 (2000)100 (1500)100 (1500)PVB1021,10 ( )210 (3000)140 (2000)140 (2000)

8 PVB1533,00 ( )180018001800140 (2000)100 (1500)100 (1500)PVB2042,80 ( )210 (3000)140 (2000)140 (2000)PVB2961,60 ( )140 (2000)100 (1500)100 (1500)PVB4594,50 ( )210 (3000)140 (2000)140 (2000)PVB90197,50 ( )180012001200210 (3000)140 (2000)140 (2000)Maximum Inlet PressureAll Pumps except PVB5/6/10/15 with H, M or V controls1,0 bar (15 psi).. PVB5/6/10/15 with H, M or V controlsAs Max. outlet pressure above.. for appropriate Drain PressureSee Installation data section, on page Inlet PressureSee following on oil viscosity of 21 cSt (102 SUS) and at 50 C (120 F).0,60,81,01,21,41,61,8barpsi1020301525 Absolute pressureSupercharge pressure0,60,8bar0,20,401200240018003600 3000 Drive speed, r/minPFB5 and PVB5psi1005 Vacuum:170 m bar(5 Hg)60000,60,81,01,21,41,61,8barpsi102030 1525 Absolute pressureSupercharge pressure0,60,8bar0,20,401200240018003200 3000 Drive speed, r/minpsi1005 Vacuum:170 m bar(5 Hg) Data Minimum Inlet pressure (cont d)0,60,82,01,01,21,41,61,8barpsi10203015 25 Absolute pressureSupercharge pressure0,60,81,0bar0,20,403000 Drive speed, r/minPVB15psi101505 Vacuum.

9 170 m bar(5 Hg)0,60,81,01,21,41,61,8barpsi1020301525 Absolute pressureSupercharge pressure0,60,8bar0,20,402000280024003200 Drive speed, r/minPFB10 and PVB10psi1005 Vacuum:170 m bar(5 Hg)0,60,81,01,21,41,61,8barpsi10201525 Absolute pressureSupercharge pressure0,60,8bar0,20,400600120018002400 Drive speed, r/minPFB20psi1005 Vacuum:170 m bar(5 Hg)00,60,82,01,01,21,41,61,82,22,42,6bar psi10203040152535 Absolute pressureSupercharge pressure0,60,81,01,21,41,6bar0,20,400160 020002400 Drive speed, r/minPVB20 and PVB29psi1020152505 Vacuum:170 m bar(5 Hg)1800220014001800240012000,60,81,01,21 ,41,61,8barpsi10201525 Absolute pressureSupercharge pressure0,60,8bar0,20,40 Drive speed, r/minPVB45psi1005 Vacuum:170 m bar(5 Hg)1800220020002100190000,60,81,01,21,41 ,61,8barpsi10201525 Absolute pressureSupercharge pressure0,60,8bar0,20,40120014001800 Drive speed, r/minPVB90psi1005 Vacuum:170 m bar(5 Hg) oil at 21cSt (102 SUS) and at 49 C (120 F).

10 Atmospheric inletDeliveryEfficiency, %02040608010000 Torque51010020030040001020 L/minkWNmlbf inhpInput powerUS gpm1050010203040 Efficiency, %020406080100 DeliveryL/minUS gpmkWhpInput powerTorqueNmlbf in151050 PFB1015525 PFB2005001000150020000102030 Efficiency, %020406080100 DeliveryL/minUS gpmkWhpInput power15105020 TorqueNmlbf in05010015020025024681002040010300102020 4060800 Outlet pressure0500 1000 1500 2000 2500 3000psi0100210bar50150 Outlet pressure0500 1000 1500 2000 2500 3000psi0100210bar50150 Outlet pressure05001000150020002500psi0100175ba r50150 For data at drive speed of 1800 r/min, see pages Data at 1500 r/min Drive oil at 21cSt (102 SUS) and at 49 C (120 F).