Transcription of B208 Octo-input Module
1 Intrusion Alarm Systems | B208 Octo-input Module B208 Octo-input Module u Programmable input point functions u Easy to read switch addressing u 2 interconnect wiring connectors u Provides eight points The B208 Octo-input Module is an 8 point expansion Certifications and approvals device that connects to the control panel through the SDI2 bus. This Module is fully supervised and The following table lists regulatory approvals by communicates back to the control panel all point region. status changes. The Module expansion points operate Region the same as the points on the control panel. Industrial, commercial, and institutional facilities are US UL 365 - Police Station Connected Burglar Alarm Units typical installations for the B208 Module . The B208 and Systems connects to the SDI2 bus on the control panel using UL 609 - Local Burglar Alarm Units and Systems SDI2 terminals, or using the interconnect cable.
2 You can connect multiple B208 modules to a single control UL 636 - Holdup Alarm Units and Systems panel. The B208 address switches allow for ease of UL 864 - control Units and Accessories for Fire Alarm use in device addressing. Systems (Commercial Fire). System overview UL 985 - Household Fire Warning System Units The B208 Octo-input Module connects to a control UL 1023 - Household Burglar Alarm System Units panel through the SDI2 bus. This Module is supervised and communicates back to the control panel all point UL 1076 - Proprietary Burglar Alarm Units and Systems status changes. The Module 's expansion points UL 1610 - Central Station Burglar Alarm Units operate the same as the points on the control panel. CSFM - California Office of The State Fire Marshall Functions FCC Part 15 Class B. Loop inputs FDNY - Fire Department of New York The B208 uses up to eight inputs which may be Normally Open (NO), or Normally Closed (NC) with 1k FM 3010 - Fire Alarm Signaling Systems EOL resistor(s) for supervision.
3 Canada CAN/ULC S303 - Local Burglar Alarm Units and Systems 2 | B208 Octo-input Module CAN/ULC S304 - Signal Receiving Centre and Premise Environmental considerations ICES-003 - Information Technology Equipment (ITE) Relative humidity 5% to 93% at +32 C (+90 F). ULC-ORD C1023 - Household Burglar Alarm System Units Temperature (operating) 0 C to +49 C (+32 F to +120 F). ULC-ORD C1076 - Proprietary Burglar Alarm Units and Power requirements System Current 35 mA. The following table lists the certificates available for download from the Product Page at Voltage 12 VDC nominal Wiring Region Certification SDI2 wiring Maximum distance Wire size USA UL 20130109-S5579; UL 864 - control (unshielded wire only): 12 in ( Units and Accessories for Fire Alarm cm). Systems; UL 636 - Holdup Alarm Units and Systems; UL 1076 - Propietary Bur- Wiring Maximum distance Wire size glar Alarm Units and Systems; UL 1610 - (unshielded wire only): 1000 ft (305.)
4 Central Station Burglar Alarm Units; UL m) 22 AWG ( mm). 365 - Police Station Connected Burglar 1000 ft (305 m) 18 AWG (2 mm). Alarm Units and Systems; UL 609 - Local Burglar Alarm Units and Systems; Unshielded wire only UL985 - Residential Fire Warning Sys- tem control Units; UL 1023 - Household Loop inputs Burglar-Alarm System Units; ULC/ORD. C1076 - Proprietary Burglar Alarm Units Loop Inputs Up to eight inputs. Input contacts may and Systems; ULC-S304-06 - Signal Re- be Normally Open (NO) or Normally ceiving Centre and Premise Burglar Closed (NC) with 1k EOL resistor(s). Alarm control Units; ULC-S303-M91 - Local Burglar alarm Units and Systems; for supervision. Note: Normally Closed ULC-ORD C1023 - Household Burglar- (NC) is not permitted in Fire Alarm System Units installations. CSFM see our website Compatibility FDNY- #6174 UL 864 9th Edition For UL 864 compliance, use a UL commercial fire CoA approved control panel.
5 Installation/configuration notes control panels b9512g / b9512g -E (Up to 59. modules). Wiring considerations B8512G/B8512G-E (Up to 9 modules). The Module to the control panel using the PWR, A, B, B5512/B5512E (Up to 4 modules). COM terminals on the control panel using the screw B4512/B4512E (Up to 2 modules). terminal strip or the interconnect wiring connector. D9412GV4 (Up to 24 modules). D7412GV4 (Up to 7 modules). Use 12 AWG to 22 AWG ( mm to mm) wires D7212GV4 (Up to 3 modules). from the Module to the control panel. Parts included Ordering information B208 Octo-input Module Quantity Component Provides 8 programmable inputs. 1 Octo-input Module Order number B208. 1 Hardware pack 1 interconnect cable 1 Literature pack Technical specifications Properties Dimensions in x in x in ( cm x cm x cm). 3 | B208 Octo-input Module Represented by: Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Security Systems, Inc.
6 Bosch Security Systems Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 130 Perinton Parkway Box 80002 Systems 203 Building, No. 333 Fuquan Road Via Anhanguera, Km 98. Fairport, New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900. Phone: +1 800 289 0096 Phone: + 31 40 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil Fax: +1 585 223 9180 Fax: +31 40 2577 330 Phone: +65 6571 2808 200335 China Phone: +55 19 2103 2860. Fax: +65 6571 2699 Phone +86 21 22181111 Fax: +55 19 2103 2862. Fax: +86 21 22182398 Bosch Security Systems 2015 | Data subject to change without notice 2536957579 | en, V7, 08. May 2015.