Example: marketing

B450 Conettix Plug-in Communicator Interfaces

Intrusion Alarm Systems | B450 Conettix Plug-in Communicator InterfacesB450 Conettix Plug-in CommunicatorInterfaces uFull two-way IP communication using Plug-inCellular CommunicatorsuPlug and Play installation makes future radiotechnology changes easyuCompatible with new and most deployed Boschcontrol panelsuSupports remote installation of cellular modules forimproved signalThe Conettix Plug-in Communicator Interface is a four-wire powered SDI2, SDI, or option bus device thatprovides two-way communication with compatiblecontrol panels over commercial cellular networksusing a Plug-in Communicator (available separately).

B450-M) work with plug-in communicators for primary or backup alarm communication, remote programming, and other remote applications. The plug-in communicator interface supports Conettix IP protocol with full authentication, 256-bit AES encryption, and resistance to Denial of Service attacks. The interface

Tags:

  B405

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of B450 Conettix Plug-in Communicator Interfaces

1 Intrusion Alarm Systems | B450 Conettix Plug-in Communicator InterfacesB450 Conettix Plug-in CommunicatorInterfaces uFull two-way IP communication using Plug-inCellular CommunicatorsuPlug and Play installation makes future radiotechnology changes easyuCompatible with new and most deployed Boschcontrol panelsuSupports remote installation of cellular modules forimproved signalThe Conettix Plug-in Communicator Interface is a four-wire powered SDI2, SDI, or option bus device thatprovides two-way communication with compatiblecontrol panels over commercial cellular networksusing a Plug-in Communicator (available separately).

2 System overviewConettix Plug-in Communicator Interfaces (B450/B450-M) work with Plug-in communicators for primaryor backup alarm communication, remote programming,and other remote applications. The plug-incommunicator interface supports Conettix IP protocolwith full authentication, 256-bit AES encryption, andresistance to Denial of Service attacks. The interfacealso supports compatible Bosch control panels withSIA DC-09, CSV-IP. The interface is a reliable way toadd cellular network communications to existing ornew commercial security and fire 563489 Callout DescriptionCallout Description1 Compatible control panel6 Cellular carrier network2 Panel data bus (SDI2, SDI, oroption)7 Internet/LAN/WAN3 Module8 Remote Programmingworkstation4 USB connection for moduleconfiguration9 Compatible IP receiver(Bosch D6100 IPv6 shown)5 B44x Plug-in Communicator (available separately)

3 FunctionsConettix IP communicationThe following features are supported with the plug-incommunicator interface via BOSCH Conettix IPprotocol and SIA DC-09 UDP, CSV-IP on supportedcontrol panels including: IP Alarm communication Remote programing Personal notification via text or email on supportedpanelsAddressingUse the address switch to easily assign a bus addressor setup for USB or SMS configuration where configurationFor most installations, the default plug-incommunicator interface settings allow installation withno device programming required.

4 An address switchallows easy bus address customized network settings, the interfacessupport a USB configuration menu, or configuration viaSMS. The following control panels support RPSprogramming: B9512G/B9512G-E B8512G/B8512G-E B6512 B5512/B5512E B4512/B4512E B3512/B3512E D9412GV4/D7412GV4/D7212GV4 LEDsThree LEDs provide status and Communicator and control panel connectionstatusRXAn inbound packet is received on the busTXAn outbound packet is transmitted on the busCertifications and approvalsNoticeThe B450-M has received certifications only asnoted.

5 If not noted, the certification applies to theB450 compliance/quality marksEuropeCEEMC, LVD, RoHSBelgiumINCERTANPI-ID-0004-0001 ANPI-ID-0004-0001-2 USAULUL 365 - Police Station Connected Bur-glar Alarm UnitsULUL 636 - Holdup Alarm Units and Sys-temsRegionRegulatory compliance/quality marksULUL 1023 - Household Burglar Alarm Sys-tem UnitsULUL 1076 - Proprietary Burglar AlarmUnits and SystemsULUL 1610 - Central Station Burglar AlarmUnitsULUL 985 - Household Fire Warning Sys-tem Units (6th edition)ULUL 864 - Standard for Control Units andAccessories for Fire Alarm Systems(10th edition)

6 CSFMC alifornia State Fire MarshalFCCPart 15 Class BFDNY-CoA6286 D7412GV4 D9412GV4 NYC COA6286 2018-2021 FDNY-CoA6196 CanadaULCCAN/ULC S303 - Local Burglar AlarmUnits and SystemsULCCAN/ULC S304 - Standard for Signal Re-ceiving Center and Premise BurglarAlarmULCCAN/ULC S545 - Residential Fire Warn-ing System Control UnitsULCULC-ORD C1023 - Household BurglarAlarm System UnitsULCULC-ORD C1076 - Proprietary BurglarAlarm Units and SystemsICICES-003 - Information TechnologyEquipment (ITE)BrazilANATEL2708-14-1855 Installation/configuration notesMounting considerationsInstall in a location with acceptable wireless networksignal strength.

7 Mount the module into the interior ofa compatible enclosure. Use the 3-hole mountingpattern. Use the supplied mounting considerationsThe interface connects to a control panel using a databus connection via the module s terminal strip, or themodule s interconnect wiring data bus powered installations outside thecompatible control panel enclosure, follow themaximum wiring distances in the | B450 Conettix Plug-in Communicator InterfacesControl panels -B450B9512G/B8512GB6512/B5512/B4512/B351 2 (B5512E/B4512E/B3512E with firmware andhigher)D9412GV4/D7412GV4/D7212GV4( +)D9412GV3/D7412GV3/D7212GV3D9412GV2/D74 12GV2/D7212GV2 ( +)

8 FPD-7024 ( +)CMS 6/8 CMS 40 Easy Series (v3+)AMAX 2100/3000/4000 Solution 2000/3000*Control panels -B450-M*AMAX 2000/2100/3000/4000/*Solution 2000/3000 CellularcommunicatorsB442 (3G GPRS GSM)B443 (3G/4G HSPA+ GSM)B444 (4G VZW LTE)EnclosuresB10B11D8103D203 ApplicationsTera Term (for USB B450 configuration)Hyper Terminal (for USB B450 configuration)RPS version or higherRemote Security Control (Supported on GV4,B9512G/B8512G, B9512G-G/B8512G-E,B6512/B5512/B4512/B351 2, B5512%/B4512E/B3512E, and Solution 2000/3000 Remote Security Control+ (Supported onAMAX and Solution Series control panel)*The B450-M is compatible with AMAX and Solution control panels busDetailsIP EventReportingYYTCP protocolsonlysupported onSDI2 RemoteProgram (RPSor A-link)YYRequiresBosch Cellularservice orother cellularnetworkaccessConfigureB450 fromcontrol panel(RPS, A-link))

9 NYGV4/B +, , busDetailsPersonalNotificationvia SMS orEmailNYRequirescompatiblecontrol paneland cellularplanRemoteSecurityControl AppNY*RequiresBosch Cellularservice orother cellularnetworkaccessCellular technology compatibilityDeviceCellular networks2G(CDMA)3G(CDMA)GPRS(GSM)HSPA+(G SM)4G(LTE)B440/B440-C*XX B441/B441-C*X B442* X B443* XX B444* X*Check for availability in your specificationsEnvironmentalRelative humidityUp to 93% at +32 C (+90 F) non-condensingOperatingtemperature0 C to +50 C (+32 F to +122 F)MechanicalDimensions79 mm x 128 mm x 38 mm ( in x in in)ElectricalCurrent(operating)Standby: With cellular Communicator = 60 mAAlarm: With cellular Communicator = 180 mAVoltage (operating)(Bus operation): 12 VDC nominalWiring3 | B450 Conettix Plug-in Communicator InterfacesData bus wiregauge12 AWG to 22 AWG ( mm to.)

10 06 mm)USB cableUSB cable (Type A to A male-to-male) notsuppliedData bus wirelengthMaximum Distance wire size22 AWG ( mm) - 12 m (40 ft)18 AWG ( mm) - 30 m (100 ft)16 AWG ( mm) - 48 m (158 ft)12 AWG ( mm) - 122 m (400 ft)You can extend the wire distances 300 m (1000ft). Use a separate power supply, such as theB520 Auxiliary Power Supply informationB450 Plug-in Communicator InterfaceSupports two-way IP communications using plug-incellular communicators for compatible control panelsOrder number B450B450-CHI Plug-in Communicator InterfaceSupports two-way IP communications using plug-incellular communicators for Bosch 8500 and 5500 Series Control PanelsOrder number B450-CHIB450-M Plug-in Communicator interface.