Intrusion Alarm Systems - B6512 IP control panel, 96 pointsB6512 IP control panel, 96 pointsB SeriesuProvides up to 96 points using a combination ofhardwired or wireless devices for installationflexibility and up to 6 areas with perimeter andinterior controluOn-board Ethernet port for conettix IP alarmcommunication and remote programming,compatible with modern IP networks includingIPv6/IPv4, Auto-IP, and universal Plug and PlayuInstaller-friendly features for simple installationand communications, including plug-in PSTNand cellular communication modulesuProvides up to 4 access doorsThe B6512 integrates intrusion and residential fire,providing one simple user interface for both B6512 provides up to 96 individually identifiedpoints that can be split into 6 control panel can communicate through its built-in Ethernet port, or through compatible plug-inmodules that can send events over the publicswitched telephone network (PSTN) or over cellularnetwork the B6512 , you can monitor doors, windows, andmotion within areas like showrooms or those thathold inventory.

u On-board Ethernet port for Conettix IP alarm communication and remote programming, compatible with modern IP networks including IPv6/ IPv4, Auto-IP, and Universal Plug and Play u Installer-friendly features for simple installation and communications, including plug-in PSTN and cellular communication modules

Tags:

  Universal, Conettix

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of B6512 IP control panel, 96 points

1 Intrusion Alarm Systems - B6512 IP control panel, 96 pointsB6512 IP control panel, 96 pointsB SeriesuProvides up to 96 points using a combination ofhardwired or wireless devices for installationflexibility and up to 6 areas with perimeter andinterior controluOn-board Ethernet port for conettix IP alarmcommunication and remote programming,compatible with modern IP networks includingIPv6/IPv4, Auto-IP, and universal Plug and PlayuInstaller-friendly features for simple installationand communications, including plug-in PSTNand cellular communication modulesuProvides up to 4 access doorsThe B6512 integrates intrusion and residential fire,providing one simple user interface for both B6512 provides up to 96 individually identifiedpoints that can be split into 6 control panel can communicate through its built-in Ethernet port, or through compatible plug-inmodules that can send events over the publicswitched telephone network (PSTN) or over cellularnetwork the B6512 , you can monitor doors, windows, andmotion within areas like showrooms or those thathold inventory.

2 Each user can have a personalizedpasscode, a wireless keyfob, and an access credentialto control the programmable authority levels with restrictedprivileges to provide service, security, and cleaningpersonnel with full or limited access. Use the threeprogrammable outputs (expandable up to 91) to turnon lights or lock and unlock doors. Users can: Turn on the system to secure the stock room whileyou conduct daily business. Perform tests to ensure your system is workingproperly. Set your system to alarm immediately if a dooropens. Activate the Watch feature so a tone soundswhenever a customer enters. Set a schedule for your system to automatically turnon at closing time. Use wireless security options to customize yoursystem. Add up to 4 doors of access control using the B901 Access control monitoring stations provide 24-hour systemmonitoring with access to vital services. Professionalsecurity personnel can test the system, monitorsystem activity, and alert the police, fire department,or other emergency response teams if outputs Three programmable on-board outputs; one highcurrent using a relay, and two trigger outputs Output A, with a contact rating of 3 Amps, cansupply up to A total current from AUX PWR Outputs B and C sink up to 50 mA at 12 VDC Four alarm-output patterns Programmable bell testOutput ProfilesOutput Profiles support custom programming andprovide a way for outputs to operate based on uniqueapplication an Output Profile is created, it can be reusedand assigned to multiple outputs enabling quickoutput can create Output Profiles that define how anoutput operates when specific events occur.

3 OutputProfiles provide a way to assign and use consistentoutput effects throughout the response 20 custom point profilesIntrusion Alarm Systems - B6512 IP control panel, 96 points2 | 10 Selectable point response time Cross point capability Fire alarm verification Dangerous gas indicator includes carbon monoxide Watch modeUser interface Supervision of up to 12 keypads Custom keypad text is fully programmable throughRPS Full function menu including custom functions Authority by area and 32 character name for eachuser 14 custom authority levels to restrict systemfeatures that each user can access Programmable primary and secondary language byuser and keypad 12 available languages (any two can be concurrentlyused)User interface languagesThe following table shows the available languages perkeypad /B926MB921CB930B940W/B942/B942 WEnglish Chinese Dutch French German Greek Hungarian Italian Polish Portuguese Spanish Swedish Area configurationsLink multiple areas to a shared area such as a lobby orcommon entryway.

4 The shared area then automaticallyturns On (arms) when all associate areas are armedand turns Off (disarms) when any one associate areais disarmed. For higher security applications, the AreaRe-Arm feature guarantees that areas are alwaysrearmed, and are disarmed for no longer than aspecific, configurable, amount of time (for example,service time).Custom functionsFor added convenience, the installer can programcustom functions that allow customers to completecomplex tasks with one simple action. For example, acustom function can bypass a group of points and armthe system, allowing the user to perform thesefunctions with one easy command. Users can activatecustom functions with a keypad, keyfob, token, orcard, or the control panel can activate a function inreaction to a faulted point, or automatically through ascheduled event (SKED).Passcode security Two-man rule. Requires two people with two uniquepasscodes to be present at the time of opening.

5 Early ambush. Allows users to verify that the facilityis safe by requiring two passcodes. The controlpanel sends a duress event if the user does notenter the passcode a second time after inspectingthe premises. Dual authentication. Requires two forms ofidentification before processing certain systemcommands, including turning off the system andopening doors. A standard system user must have apasscode, a credential (token or card), andappropriate command authority controlUsing the B901 Access control Module, the controlpanel provides a fully supervised access controlsolution. The solution offers 14 programmable levelsof access authority. Authority for door access iscontrolled by the user level, the group of the user, thetime of day, the door state, and the area armed (On/Off) exit controlThe control panel changes from one On (armed) stateto another without turning off (disarming) the example, if you change the state from Part On(Perimeter Arm) to All On (Master Arm), the controlpanel complies and reports the change.

6 Easy exitcontrol reduces the number of keystrokes, simplifyingsystem passcode-controlled menu listPasscode-controlled shortcuts provide users only withthe options and information pertinent to them,simplifying system controlThe system provides the flexibility to choose addedconvenience or high security. For example, you canrestrict to a keypad's immediate local area turning on(arming) and turning off (disarming) the system with apasscode, even if the user has access to other is particularly useful for high security areas,Intrusion Alarm Systems - B6512 IP control panel, 96 points3 | 10where a user may have access to the area, but wouldprefer to only turn off (disarm) the area individuallyrather than with the rest of the Delay/Delayed ResponseCreate a special point profile that delays the reactionof a point for a specified time (up to 1 hour in minutesand seconds). This delay provides time for thespecified condition to reset before activating anyannunciation.

7 The system can annunciate locally andsend a report, if desired. When the system is armed,the point can respond like a normal point - providingdual functionality. Use this feature to ensure thatperimeter doors have not been propped open, or tomonitor critical areas such as computer rooms andsafes, for usersThe system supports up to 100 users. Each user canhave a personalized passcode, a wireless keyfob, andan access credential to control the system. You canassign passcodes to one of 14 customized authoritylevels in each area that can be restricted to operateonly during certain times. Programmable primary andsecondary language by user and keypad; select fromEnglish, Chinese, French, Greek, Hungarian, Italian,Polish, Portuguese, and groups and destinationsThe control panel can send reports to four differentroute groups using one primary and up to threebackup destination devices for each route capabilitiesThe control panel has flexible communications formost central station receivers with reportingcapabilities such as: Individual point numbers Opening or closing reports by user and area number Remote programming attempts Diagnostic reportsDestination testIt is possible to send test reports to each and alldestinations within each route formatsThe control panel sends reports in these formats.

8 Contact ID (PSTN) Modem4 (PSTN) conettix Modem4 conettix ANSI-SIA Contact ID ANSI-SIA DC-09iNoticeUL and ULC LISTED applicationsANSI-SIA DC-09 format is not available for ULand ULC LISTED communicationThe control panel can use on-board Ethernet tocommunicate with a conettix D6600 or a ConettixD6100 IPv6 communications control panel can optionally use a conettix plug-incellular communicator (B440/B441/B442/B443/B444/B444-A/B444-V) .Using conettix IP communication offers a secure paththat includes anti-replay/anti-substitution features andprovides enhanced security with up to AES 256-bitencryption (using Cipher Block Chaining (CBC)).The control panel supports Domain Name System(DNS) for both remote programming and centralstation communication. DNS provides ease of use,eliminating the need to use static IP addresses as yourreporting destination, and accommodates a simplesolution for central station disaster recovery.

9 Thecontrol panel supports both IPv6 and IPv4 pathsThe control panel accommodates up to four separatephone and four separate network paths to the centralstation receiver. When resetting alarms or turning asystem on and off, the user is identified by name notificationThe control panel can send text messages and emailsfor personal notification over Ethernet or using acellular communicator. You can configure up to 16destinations using a combination of cellular phonenumbers and email addresses. The control panelsends notifications in the user s programmed updatesRemote firmware updates are wide variety of input optionsEach point: Single 1 k , single 2 k , dual 1 k (1 k + 1 k ),and No EOL (end-of-line) (EOL) resistor options (foron-board and B208 inputs) Programmable for Fire, Intrusion, Access, Gas, andSupervisory devices Supports hardwired and wireless devices Supports IP cameras by Bosch as point and outputdevicesIP camera supportThe control panel can integrate directly with Bosch IPcameras, using them as fully supervised points of cameras allows the camera s videomotion detection to activate points on the controlpanel.

10 The IP Camera Point Source now includes twowired inputs of an IP camera. The control panel svirtual outputs (IP camera output source) can beconfigured to trigger camera actions, includingsending video snapshots via verificationEnsure priority response by law enforcement andelimination of fines for false alarms through asubscription to Bosch CBS video verification Alarm Systems - B6512 IP control panel, 96 points4 | 10 The services also optionally enable your monitoringcenter to speak real-time to an intruder to deterfurther damage to your CBS video verification service is not avail-able in Europe, the Middle East, or and fire detectionThe control panel provides eight on-board points , andup to 88 additional off-board points (depending onmodel and expansion interfaces). You can programindividual points to monitor some types of burglaralarms, fire alarms, and supervision logThe event log stores local and reported events.