Example: confidence

Banded Liner System Product Data Sheet - BayInsulation

OptiLiner . Banded Liner System Product data Sheet Roof System installed banding and fabric PureFiber Technology ROOF Sheet . support System allows roof Advantages cavities to be completely filled Verified formaldehyde-free1 and TOP LAYER. UNFACED. insulation . using two layers of soft to the touch Owens Corning EcoTouch Certified by SCS Global insulation for MBI Plus Metal Services to contain a minimum FABRIC. Building. Completely filling the of 65% recycled glass content, cavity results in minimal insulation Liner BOTTOM LAYER. UNFACED. insulation . 18% pre-consumer and 47%. BANDING. compression and maximum post-consumer System thermal performance. The amount of banding installed in the Certified to meet indoor OptiLiner System can be air quality standards under Wall System the GREENGUARD. minimized, however WORKERS. MUST USE OSHA REQUIRED Certification Program and RAFTER insulation . HANGER FALL PROTECTION WHEN the GREENGUARD Gold ROOF FABRIC INSTALLING THE Banded Certification Program Liner .

Product Data Sheet OptiLiner® Banded Liner System Meets Model Fire Code Ratings Both the fabric and insulation materials have a flame spread rating of 25 or less and a

Tags:

  Product, System, Sheet, Data, Liner, Product data sheet, Insulation, Banded liner system product data sheet, Banded

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Banded Liner System Product Data Sheet - BayInsulation

1 OptiLiner . Banded Liner System Product data Sheet Roof System installed banding and fabric PureFiber Technology ROOF Sheet . support System allows roof Advantages cavities to be completely filled Verified formaldehyde-free1 and TOP LAYER. UNFACED. insulation . using two layers of soft to the touch Owens Corning EcoTouch Certified by SCS Global insulation for MBI Plus Metal Services to contain a minimum FABRIC. Building. Completely filling the of 65% recycled glass content, cavity results in minimal insulation Liner BOTTOM LAYER. UNFACED. insulation . 18% pre-consumer and 47%. BANDING. compression and maximum post-consumer System thermal performance. The amount of banding installed in the Certified to meet indoor OptiLiner System can be air quality standards under Wall System the GREENGUARD. minimized, however WORKERS. MUST USE OSHA REQUIRED Certification Program and RAFTER insulation . HANGER FALL PROTECTION WHEN the GREENGUARD Gold ROOF FABRIC INSTALLING THE Banded Certification Program Liner .

2 Liner System AT HEIGHTS. Thickness recovery provides WALLSHEET. GIRT. COLUMN (SEE OSHA REGULATIONS AT outstanding thermal and WALL FABRIC 29 CFR 1926, SUBPART M). acoustical performance Banding reduction saves time and Liner UNFACED. insulation . BANDING BASE. installation cost without sacrificing Uses CHANNEL. excellent in place thermal OptiLiner System is a high performance. R-Value roof and wall insulation System that can be installed The OptiLiner wall System uses in metal buildings in order Description the same basic components to maximize System thermal The OptiLiner Banded Liner as the roof System . Additional performance. System is the latest metal materials included with the wall building Product offering from System are insulation hangers Product Attributes Owens Corning that is designed that are used to support unfaced Excellent Thermal Performance to maximize the thermal insulation in the wall cavities Minimal insulation compression performance of Owens Corning and foam tape that is installed in the OptiLiner roof and wall EcoTouch insulation for MBI between the wall girts and the systems allows for excellent Plus with PureFiber Technology wall sheets in order to enhance thermal performance.

3 Installing light density fiberglass insulation System thermal performance. the OptiLiner systems will help in metal building roof and wall A minimum amount of " minimize the heating and cooling applications. galvanized steel banding is costs associated with conditioning installed after the fabric is in place a metal building. Further, the The OptiLiner roof System uses to help support the insulation and OptiLiner roof and wall System a series of " galvanized steel to provide a consistent interior uses Owens Corning EcoTouch . straps to support a bright white finish with the roof System . Using insulation for Metal Building or black polyethylene fabric that both the OptiLiner roof and in every application. This will serves as the low permeance wall System will provide excellent ensure thermal performance vapor retarder for the System . thermal, acoustic and appearance and minimize any potential Fabric sections are custom fit for benefits for a metal building. performance variability based on each bay in order to ensure a the brand of insulation used in the swift installation and a clean System .

4 Interior finished appearance. The 1 Applies to the insulation component only. OptiLiner . Banded Liner System Product data Sheet Exceptional Vapor Retarder Physical Properties Custom fit fabric sections with Property Test Method Value thermally welded seams and low insulation permeance properties provide Noncombustibility ASTM E136 Noncombustible excellent long-term vapor sealing Water Vapor Sorption ASTM C1104 < 5% by weight for the System . A properly Odor Emission ASTM C1304 No objectionable odor1. installed OptiLiner System will Corrosiveness ASTM C665 No corrosion greater than comparative item help minimize concerns with Fungi Resistance ASTM C1338 No growth greater than comparative item concealed condensation. Facing Facing Permeance ASTM E96 perms Detailed System Acoustic Testing Fungi Resistance ASTM C1338 No growth greater than comparative item The OptiLiner roof and wall 1. No odor for a minimum of 3 of 5 panel members. insulation systems improve the acoustical environment both Availaiblity1 Availaiblity1.

5 EcoTouch insulation for MBI Plus insulation Systems EcoTouch insulation for MBI Plus insulation Systems inside and outside of a metal Roof Systems Wall Systems building. Multiple roof and wall constructions have been tested to Top Layer Bottom Layer insulation Single Layer of Unfaced EcoTouch . insulation insulation Total insulation for MBI Plus insulation R-Value determine their Noise Reduction R-Value R-Value R-Value 192. Coefficient (NRC), Sound 10 19 29 25. 30. Transmission Loss (STL), Sound 11 19 30. EcoTouch insulation for MBI Plus Transmission Class (STC) and 13 19 32. insulation Thickness Outdoor-Indoor Transmission 10 25 35. R-Value Thickness (inches). 16 19 35. Class (OITC) values. 11 25 36 10 13 25 38. 11 High Recycle Content of 19 19 38. 13 10 30 40. insulation Materials 11 30 41 16 All Owens Corning EcoTouch 16 25 41 19 insulation for Metal Building 13. 19. 30. 25. 43. 44 25 products are third party 16 30 46 30 certified to contain a minimum 19 30 49 1.

6 Owens Corning EcoTouch insulation for of 65% recycled content (47% Metal Building Utility Blanket is available as top layer of insulation when used in conjunction with post-consumer and 18% pre- an R-25 or R-30 bottom layer. See the Owens Corning EcoTouch insulation for Metal Building consumer). High recycled content Utility Blanket Product data Sheet for insulation helps building professionals specification compliance details. 2. R-19 should only be used in applications with a . achieve LEED certification wall girt or less. and meet other green building guidelines that are an increasingly critical measurements used in Sound Absorption EcoTouch insulation for Metal Building Roof and Wall Configurations1, 2. sustainable building. insulation Total Absorption Coefficients at Octave Band Frequencies R-Value 125 250 500 1000 2000 4000 NRC. 25 30 35 40 44 49 1. Sound absorption testing in accordance with ASTM C423. 2. All testing conducted with the facing towards the soundfield as in actual use condition.

7 OptiLiner . Banded Liner System Product data Sheet Acoustic data Sound Transmission Loss1,2. Transmission Loss - dB at Octave Band Frequencies Construction Clip Standoff Top Layer Bottom Layer Type (inches) insulation R-Value insulation R-Value 125 250 500 1000 2000 4000 STC OITC. Through 14 26 35 40 49 51 37 36. NA 10 19. Fastened Through 18 32 42 50 57 57 42 41. NA 19 30. Fastened Roofs Standing Seam 10 19 14 26 34 44 52 53 36 36. Standing Seam 19 30 19 32 42 56 63 58 42 41. Standing Seam 19 30 20 32 42 56 62 58 42 42. Foam Tape Transmission Loss - dB at Octave Band Frequencies Construction Thickness Type (inches) Single Layer insulation R-Value 125 250 500 1000 2000 4000 STC OITC. Through 15 26 35 41 50 53 37 36. 25. Fastened Walls Through 17 29 38 45 54 54 39 38. 30. Fastened 1. Sound Transmission Loss Tested in accordance with ASTM E90. 2. Values are given for design approximations only. Production and test variabilities will alter the results. Meets Model Fire Code Ratings Cleanable Facing Detailed roof and wall application Both the fabric and insulation A soft cloth with soap and water recommendations can be found materials have a flame spread or non-abrasive household in the roof and wall installation rating of 25 or less and a cleaner can be used to clean the guides for the OptiLiner System .

8 Smoke developed rating of 50 facing. Solvent-based cleaners and or less. This usually means that abrasive pads should be avoided. Technical data Insulation2. the products will be granted Fire Resistance immediate building code approval. Application ASTM E84, UL 723 or NFPA. Recommendations 255 Test Methods for Surface Bright and Resilient Interior Finish OptiLiner Roof System Burning Characteristics of Building The OptiLiner white fabric is WORKERS MUST USE Materials3 Max Flame Spread stronger than traditional facings OSHA REQUIRED FALL Index 25; Max Smoke Developed used in metal buildings. The bright PROTECTION WHEN Index 50. white color has a light reflectance INSTALLING THE Banded . rating of greater than 80%, which Liner System AT HEIGHTS. may allow for reduced lighting (SEE OSHA REGULATIONS AT. loads in the design space. 29 CFR 1926, SUBPART M). 2 EcoTouch insulation for MBI Plus products are not GREENGUARD Certified Proper safety measures should certified to the ASTM C991 standard or the NAIMA.

9 All Owens Corning EcoTouch be taken when installing the 202-96 Rev 2000 standard as these products are not designed to be post processed via lamination. insulation for Metal Building OptiLiner roof System . An Projects requiring certification to these standards should use unfaced Owens Corning EcoTouch . products are certified to meet installing contractor should insulation for Certified R Metal Building indoor air quality standards under employ a site specific fall 3 The surface burning characteristics of these products have been determined in accordance with ASTM. the GREENGUARD Certification protection plan. E84, UL 723 or NFPA 255. These standards should Program and the GREENGUARD be used to measure and describe the properties of materials, products or assemblies in response to heat Gold Certification Program. and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions.

10 However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. OptiLiner . Banded Liner System Product data Sheet Technical data Liner Fabric Material Standards ASTM C1136 Standard Specification for Flexible, Low Permeance Vapor Retarders for Thermal insulation Type I VI4. Fire Hazard Classification . Liner Fabric ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials3 Max Flame Spread Index 25; Max Smoke Developed Index 50. 4 Type I-IV exception for dimensional stability. Value is < Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient's sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any Product described herein.