RECEIVER DRIERS 2009 MEI Corporation398 ACCUMULATORSS pecification 406 Visual Numerical 409 RECEIVER DRIERSRECEIVER DRIERSS pecification 400 Barb Type (Push on) .. 405 Block, Manifold, Pad or Slimline 400 Flare Type .. 404In-Line 404O-Ring 400 Quick Disconnect 403 Visual Numerical Section .. 409 Receiver Driers, Accumulators and In-Line Filters are canisters used to filterdebris and remove moisture to protect the a/c system. Various inlet and outletfitting types and sizes are used. Many also have system protection devices,moisture indicators, charge ports, sight glass, fuse plugs, high pressure reliefvalves, mounting brackets depending on the requirements from the originalequipment Driers are usually located on the high side of the a/c system beforethe expansion valve.

RECEIVER DRIERS 400 © 2009 MEI Corporation RECEIVER DRIERS Listed in ascending order by Diameter x Length by Fitting Type and Size 1 5/8" 11 5/8" Pad Type 7557 Sprinter 680-013634AA

Tags:

  Information, Basics, Fitting, Basic information

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Basic Information - MEI Corporation

1 RECEIVER DRIERS 2009 MEI Corporation398 ACCUMULATORSS pecification 406 Visual Numerical 409 RECEIVER DRIERSRECEIVER DRIERSS pecification 400 Barb Type (Push on) .. 405 Block, Manifold, Pad or Slimline 400 Flare Type .. 404In-Line 404O-Ring 400 Quick Disconnect 403 Visual Numerical Section .. 409 Receiver Driers, Accumulators and In-Line Filters are canisters used to filterdebris and remove moisture to protect the a/c system. Various inlet and outletfitting types and sizes are used. Many also have system protection devices,moisture indicators, charge ports, sight glass, fuse plugs, high pressure reliefvalves, mounting brackets depending on the requirements from the originalequipment Driers are usually located on the high side of the a/c system beforethe expansion valve.

2 The receiver drier receives liquid refrigerant from thecondenser, stores it, filters out contaminates from the a/c system, and removesmoisture. A/C systems using a receiver drier use an expansion valve to controlthe refrigerant are similar to that of the receiver drier. It is usually mounted onthe low side, at the outlet of the evaporator. The accumulator accumulates orstores excess refrigerant, filters and dries the refrigerant. Accumulators are usedon CCOT (Cycling Clutch Orifice Tube) or FFOT (Ford Fixed Orifice Tube)systems. These systems use a orifice tube instead of an expansion valve tocontrol the refrigerant Filters are designed to be used in the liquid line in a/c systems with theorifice tube located in the evaporator. Placing the in-line filter up stream of theorifice eliminates the need to flush most systems, because the impurities aretrapped before they reach the orifice tube.

3 These filters are designed to hold upto 90 grams of debris, without a substantial penalty to the system s flow. Thescreens and filter pads inside the canister, catch particles and filters therefrigerant InformationRECEIVER DRIERST able of ContentsRelated ItemsMoisture 408 Mounting Bracket 425O-Rings & Seals .. 390 Quick Disconnect 408 Typical Drier 405 Typical Accumulator 407 DRIER MEASUREMENTSDIAMETERLENGTHF ilter Dier manufacturers have discontinued usingmoisture indicators. We will supply moisture indicatorswhere applicable while supply DRIERS 2009 MEI Corporation399 Moisture can be harmful to air conditioning systems components and to the a/c system s operation. For this reason, any time the a/csystem is opened, the receiver drier / accumulator needs to be replaced.

4 A good preventative maintenance practice is to replace thereceiver drier or the accumulator and orifice tube at regular intervals or at least once per year. When replacing a compressor, the a/ccompressor manufacturer s warranty will be void without proof of flushing the system, and also replacement of the receiver Indicator - a litmus paper device which turns colors to designate condition of the - Normal, Pink - Moisture in system, White - Very Wet, Grayish - oil have discontinued using moisture indicators. We will supply until stock is Relief Valve / Fuse Plug - A protection device designed to open and bleed off excessive pressure that may Fuse Plug is a bi-metal device which will melt down to release excess - a window for observing the condition of the Valve - a gauge or charge port which allows access to the system, for charging or checking the Port - Low / High Pressure Switches - a switch port allows for a male or female pressure switch to be added to the drier.

5 If lowcharge is detected, the low pressure switch opens electronically and stops the compressor operation. Similarily, as pressure increases,the high pressure switch will dis-engage the clutch and re-engage when pressure DRIERSQ uickDisconnectQuickDisconnectMoistureInd icatorMoistureIndicatorSightGlassSightGl assSightGlassBarb TypeMale FlareTypeMale O-RingTypeFemale O-RingTypeCharge/Gauge PortCharge/Gauge PortHigh PressureRelief ValveHigh PressureRelief ValveLow / HighPressure SwitchFusePlugFemaleO-RingTypeMaleO-Ring TypeCharge/Gauge PortHigh PressureRelief ValveTypical Examples:Slimline Manifold - Block TypeMaleSpringlock TypeFemaleSpringlock TypeMetric Schrader Valve uses green o-ring indicator is not required and may not be supplied on DRIERS 2009 MEI Corporation400 RECEIVER DRIERSL isted in ascending order by Diameter x Length by fitting Type and Size1 5/8"11 5/8"Pad Type7557 Sprinter 680-013634AA3"10"SlimLine7197 2 M10 TopABPN83-3197443"10 1/4"SlimLine (#0126 seals)7198 2 M10 TopABPN83-3195343"10 1/2"Pad /Block754516mmVolvo OffRoad 111045673"11"Manifold Style7393 Kenworth F37-60003" "3/8" #6 Springlock7564 New Holland 89154-003 7/16"9 1/2"Pad Type7415 Navistar 3542577C24"7"Block Style7559A22-63992-000.

6 -0014"7"Block Style7566A22-63994-0014"7"Pad Type7556 Sprinter 051-03570AA4"7"Pad Type7561 Freightliner A22-63993-001 PARTNUMBERS ightGlassSwitchPortFusePlugSchraderValve PressureRelief ValveLow PressureSwitchPad Type, Block, SlimLine, Springlock or Manifold Style Dier manufacturers have discontinued using moisture will supply moisture indicators where applicable while supply 1/2"5 1/8"3/8" #6 FOR 3/8" #67181 TopBottomInternal Fuse PlugR12/R134a2 1/2"6"3/8" #63/8" #67532 Side3/8" PortR12/R134a2 1/2"6 5/16"3/8" # M127513 TopTop(1) Top M10; 33-0038AR12/R134a2 1/2"6 5/16" M127514 TopTop(1) Top M10; 33-0382AR12/R134a2 1/2"6 5/16" M187515 TopTop(1) Top M10; 33-0383AR12/R134a2 1/2"6 5/16" Male7519 TopM10 Switch PortR12/R134a2 1/2"6 5/16"M18M187524 TopM10 Switch PortR12/R134a2 1/2"6 5/8"3/8" Flare3/8" Flare7158 TopSideMale Flare2 1/2"6 3/4"3/8" #6 MOR 1/2" #87140In-Line DesignR12/R134a2 1/2"6 3/4"M18 MOR M207503In-Line Drier.

7 15982368R12/R134a2 1/2"7 1/2"3/8" #63/8" #67376 Single BracketR12/R134a2 1/2"8"3/8" #63/8" #67118 Top Top A22-14425-2R12/R134a2 1/2"8"3/8" #63/8" #67120 TopTop7118, 1430 (3/8"-24 Male)R12/R134a2 1/2"8"3/8" Male QD7563 Motorhome 54-00011R134a2 1/2"8 1/4"3/8" #63/8" #67480 Top1/4" TopBracketR12/R134a2 1/2"9 1/2"3/8" #63/8" #67207 Single BracketR12/R134a2 1/2"9 1/2"3/8" #63/8" #67219 Single BracketR12/R134a2 1/2"9 3/4"3/8" #63/8" #67360 Bracket w/NutsR12/R134a2 1/2"10"1/2" #81/2" #87502R12/R134a2 1/2" Diameter - 3/8" Male O-Ring INLETPARTNUMBERS ightGlassFusePlugSchraderValveMoistureIn dicatorPressureRelief ValveLow DRIERS 2009 MEI Corporation401 RECEIVER DRIERSL isted in ascending order by Diameter x Length by fitting Type and Size3"6"3/8" #63/8" #67125 Top SideSideR12/R134a3"6 1/4"3/8" #63/8" #67124 TopSideR12/R134a3"6 1/4"3/8" #63/8" #67129 TopSideR12/R134a3"6 1/2"3/8" #63/8" #67123 Top SideTopSideR12/R134a3"6 1/2"3/8" #63/8" #67126 Top1/4"

8 SideSideR12/R134a3"6 1/2"3/8" #63/8" #67127 TopSideBinary (Side)R12/R134a3"6 1/2"3/8" #63/8" #67128 TopSideTrinary (Side)R12/R134a3"6 1/2"3/8" #63/8" #67555 TopTopSideRD5-9419-0R134a3"8"3/8" #63/8" #67161 TopSide(2) 1/4"(2) 1/4" PortsR12/R134a3"8 1/4"3/8" #63/8" #67133 Top TopTopSideR12/R134a3"8 1/4"3/8" #63/8" #67141 Side TopR12/R134a3"8 1/4"3/8" #63/8" #67143 TopSide1/4" Side TopR12/R134a3"8 1/2"3/8" #63/8" #67229 Top FemaleSideSideSide SideIncludes Low Press SwitchR12/R134a3"8 1/2"3/8" #63/8" #67180 Top (2)(2) M10 x "9"3/8" #63/8" #67159 Top1/4" Top TopSideR12/R134a3"9"3/8" #63/8" #67164 Top SideTopSide1/8"-27 NPT PortR12/R134a3"9"3/8" #63/8" #67174 TopSideR12/R134a3"9"3/8" #63/8" #67185 TopTopInlet - Right AngleR12/R134a3"9 3/4"3/8" #63/8" #67346 TopR12/R134a3"10"3/8" #63/8" #67193 TopTop1/4" SideWester StarR12/R134a3"10"3/8" #63/8" #67132 Side TopSideSideR12/R134a3"10"3/8" #63/8" #67134 Top TopTopSideR12/R134a3"10"3/8" #63/8" #67165 Top1/4" Top TopTopR12/R134a3"10"3/8" #63/8" #67166 TopM10 Top TopTopM10 x "10"3/8" #63/8" #67167 Side TopSideTopMack Trk 221RD331R12/R134a3"10"3/8" #63/8" #67175 SideR12/R134a3"10"3/8" #63/8" #67189 TopTopw/side mounting bracketR12/R134a3"10"3/8" #63/8" #67190 TopTopw/side mounting bracketR12/R134a3"10"3/8" #63/8" #67191 Topw/side & top mntg

9 BrktsR12/R134a3"10 1/2"3/8" #63/8" #67171(2) 1/4"(2) 1/4" PortsR123" Diameter - 3/8" Male O-Ring INLET x 3/8" Male O-Ring OUTLETLow PressureSwitchPARTNUMBERS ightGlassSwitchPortFusePlugSchraderValve MoistureIndicatorPressureRelief 3/4"10"3/8" #63/8" #67154 TopSideSideR12/R134a2 3/4"10"3/8" #63/8" #67155 Top1/4" SideSideMack 221RD328; 7156 + 8900R12/R134a2 3/4"10"3/8" #63/8" #67156 Top SideSideR12/R134a2 3/4"10"3/8" #63/8" #67157 TopSidew/ Trinary Switch - SideR12/R134a2 3/4"10"3/8" #63/8" #67388 Side TopSideKenworth K251-263R12/R134a2 3/4"10"3/8" #63/8" #67389 SideTop7388 + 8900R12/R134a2 3/4"10"3/8" #63/8" #67390 SideSidew/ Trinary Switch - TopR12/R134a2 3/4" Diameter - 3/8" Male O-Ring INLET x 3/8" Male O-Ring OUTLETPARTNUMBERS ightGlassSwitchPortFusePlugSchraderValve MoistureIndicatorPressureRelief ValveLow DRIERS 2009 MEI Corporation4024"5 1/4"3/8" #63/8" #67214 TopSideR12/R134a4"6 1/2"3/8" #63/8" #67394 TopSidew/mounting bracketR12/R134a4"6 3/4"3/8" #63/8" #67565 SideVolvo RD5-6075-0R134a4"7"3/8" #63/8" #67481 SideFord Tractor E4NN-19825 AAR12/R134a4"7"3/8" #63/8" #67232 TopSideOpposite Side

10 InletR12/R134a4"7 3/4"3/8" #63/8" #67391 TopTopSide SideR134a4"8 1/2"3/8" #63/8" #67234 TopSideTopR12/R134a3"8"3/8" #63/8" #67135 Top(2) 1/4"TopSideR12/R134a3"8"3/8" #63/8" #67170 Top(2) M10 TopSide(M10 x )R12/R134a3"8 1/4"3/8" #63/8" #67172 Top(2) 1/4"TopTopPeterbilt 18-03638R123"10"3/8" #63/8" #67160 Top(2) 1/4"TopSidesimilar to #7135R12/R134a3"10"3/8" #63/8" #67169 Top(2) M10R12/R134a3"8 1/4"11/16" #63/8" #67107 Top alternate #7130; Kysor 402567R12/R134a3"10"11/16" #63/8" #67131 TopTopTopSide 7/16" Female InletR12/R134a3"10"11/16" #63/8" #67130 TopTop alternate #7131R12/R134a3"10"11/16" #63/8" #67230 TopTop ParkerType; IHC 1693117C1R134a3"10"3/8" #63/8" #67387 SideTopK251-459, K251-571, K251-566R12/R134aRECEIVER DRIERS3" Diameter - 3/8" Male O-Ring INLET x 3/8" Female O-Ring OUTLETPARTNUMBERS ightGlassSwitchPortFusePlugSchraderValve MoistureIndicatorPressureRelief ValveLow PressureSwitchListed in ascending order by Diameter x Length by fitting Type and Size4" Diameter - 3/8" Male O-Ring INLET x 3/8" Male O-Ring OUTLETPARTNUMBERS ightGlassSwitchPortFusePlugSchraderValve MoistureIndicatorPressureRelief ValveLow PressureSwitch3" Diameter - 3/8" Female O-Ring INLET x 3/8" Female O-Ring OUTLETPARTNUMBERS ightGlassSwitchPortFusePlugSchraderValve MoistureIndicatorPressureRelief ValveLow PressureSwitch3" Diameter - 3/8" Female O-Ring INLET x 3/8" Male O-Ring OUTLETPARTNUMBERS ightGlassSwitchPortFusePlugSchraderValve MoistureIndicatorPressureRelief ValveLow Dier