BATTERIES TECHNICAL DATA

OPzS. BATTERIES . TECHNICAL . DATA. OPzS and OPzV. STATIONARY BATTERIES . tab opzS. Low maintenance TAB OPzS. TECHNICAL DATA AND DIMENSIONS. 6V 4 OpzS 200 vented stationary BATTERIES Rated Type of voltage plates Number of Capacity at positive plate 10-hour discharging H. W. L. Let us lead you into the world of everlasting energy terminal post and introduce you with OPzS stationary blocks and cells bolted version produced in the conventional lead-acid technology. The BATTERIES are distinguished for: Operation high capacity maintenance long life time reduced maintenance It is recommended that low self-discharging quick and simple acid the OPzS BATTERIES are level control installed in the systems economical water consumption where they are constantly appropriate dimensions connect

Low maintenance taB oPzS 6v 4 oPzS 200 vented Stationary BatterieS Rated voltage Number of positive plate Type of plates Capacity at 10-hour discharging

Tags:

  Technical, Batteries, Batteries technical

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of BATTERIES TECHNICAL DATA

1 OPzS. BATTERIES . TECHNICAL . DATA. OPzS and OPzV. STATIONARY BATTERIES . tab opzS. Low maintenance TAB OPzS. TECHNICAL DATA AND DIMENSIONS. 6V 4 OpzS 200 vented stationary BATTERIES Rated Type of voltage plates Number of Capacity at positive plate 10-hour discharging H. W. L. Let us lead you into the world of everlasting energy terminal post and introduce you with OPzS stationary blocks and cells bolted version produced in the conventional lead-acid technology. The BATTERIES are distinguished for: Operation high capacity maintenance long life time reduced maintenance It is recommended that low self-discharging quick and simple acid the OPzS BATTERIES are level control installed in the systems economical water consumption where they are constantly appropriate dimensions connected to the rectifier.

2 And weight the lowest and constant The battery can be float-charged with maintenance current. voltage of to V/cell, or, in case The individual cells (2V) and blocks of rapid charging after discharge, with (6V and 12V) are in translucent plastic voltage of to V/cell. containers made of styrenacrylnitril Rapid charging usually lasts another (SAN), a material which is extraordinary 3-5 hours after the voltage has already resistant to chemical influences and reached to V/cell. After mechanical damage. that, an automatic switchover to the The stationary BATTERIES of the type constant maintaining voltage of terminal post OPzS are manufactured according to to V/cell takes place.

3 Battery main- welded version the DIN 40736, EN 60896 and IEC 896-1 tenance is reduced to a mimimum and regulations. required only from time to time. At normal operation, only some destilled water has to be added Application once in a 2-3 year period and, if necessary, the surface of cells Stationary BATTERIES of the OPzS type has to be cleaned. All stated are intended for the supply of tele- voltage values are valid for the communication facilities, computers, temperature range from 15 to 25. emergency lightning, alarm, control and degrees C.

4 Out of this range, the monitoring systems in power plants corrections given by the battery and distribution stations, at railway producer are necessary. stations, airports etc. Due to their extremely low self- dis- For detail information charging they are suitable for plants please check our supplied by solar cells. operation manual. Orders In order that the BATTERIES would meet all your demands, we kindly ask you to enclose the following data with your order: kind of consuming device type of rectifier, its characteristics, (telephone plant, DC-AC converter, regulating point I (A) or U (V), respec- emergency lightning etc.)

5 Tively, float voltage (V) (direct voltage operating energy of the consumer of rapid-charging current Imax (A), (kW, kVA, cos ) float charging voltage). minimum and maximum allowable outline or dimensions of rated voltage at consuming device (V) a battery room time diagram of a consumer type of installation (welded, bolted, load, and the required time on wooden or metal racks, in case, on autonomy (reserve) earthquake-proof racks). expected voltage drop in the battery maintenance accessories supply lines (areometers, thermometers, jug.)

6 Surrounding temperature in the battery type: filled up with battery room (average, minimum, electrolyte and electrically charged maximum) or dry-charge battery. In case of problems with ordering we will be glad to advise and assist you in the selection of the suitable type of battery. Construction The positive armored plate is of a improved tubular type, which means that the design active substance (PbO2) is contained in special gauntlet made of polyester for bolted fibres and hardened by an impreg- version nation compound.

7 Such construc- tion prevents escaping of an active terminal post substance during the operation and ensures a long life time. The grids of a positive and a negative New type plate are made of special low percent- age (less than 2 %) antimony alloy with of pole for addition agents for improvement of stationary crystalline structure of casting. Negative plates are pasted-type applications has plates with special alloys maintaining porosity of an active substance dur- a special design ing the operation. As an electrolyte, a with embraced A cell plug seals well (ceramic filter), diluted sulphuric acid (H2SO4) with a density of kg/l at 20 degrees and prevents leakage of any sulphuric injected plastic C, and at a maximum permitted level is acid vapours, however, it lets through hydrogen and oxygen.

8 Around pre- used. Separators separating the posi- tive plates from the negative ones are machined lead made of microporous plastic material Two versions of BATTERIES are part in the with a low electric resistance. being manufactured: The cell containers are made of Dry-charge version: sealing area. transparent SAN, while lid of a battery has to be filled up with nontransparent SAN or ABS material an electrolyte and supplementary Plane and clean surface of (SAN for blocks, ABs for 2V cells). charged before use. plastic part in combination In a special process, the lids are tightly The plates are already formed and with rubber sealing ring sealed to the container.

9 The terminal in a special process protected ensures perfect seal. Long plugs are sealed with rubber seals. against oxidation. plastic injected part allows This prevents any escape of electro- They can be stored without problems. pole growth and moving lyte from the cells. Electrolyte-charge: upwards by the growth Due to the transparent containers the battery can be installed immediately, of positive plate. Such electrolyte level is clearly visible, the because it is already filled up with construction ensures tight maximum and minimum levels are electrolyte and electrically charged pole bushing without any marked on a self-adhesive acid-proof as well.

10 The capacity test has already corrosion or deterioration label on a container side. been performed by the producer. during battery life. tab opzS (BLOCKS)* and cells TAB OPzS stationary Design blocks (cells) are OPzS cells (block)*. produced in the positive electrode conventional lead- Tubular plate with low antimony alloy (<2 %). acid technology. negative electrode Flat with long life expander active material Stationary BATTERIES separation Microporous separator of the OPzS type electrolyte are intended for the Sulphuric acid of 1,24 kg/l supply of telecommu- at 20 C.