The DataSafe HX Range of valve regulated lead acid batteries hasbeen designed to offer superior solutions for the UninterruptiblePower Supply (UPS) and Information Technology markets. DataSafeHX batteries are the ideal source of power to protect vital systemsand incorporates select design features that maximise reliability whileensuring superior performance and an excellent service HX batteries are designed using proven gas recombinationtechnology that removes the need for regular water addition bycontrolling the evolution of hydrogen and oxygen during use of gas recombination technology for lead acid batteries hastotally changed the concept of standby power. This technologyprovides the user with the freedom to use lead acid batteries in awide Range of on advanced electrochemistry and backed by over 100 yearsexperience in Battery technology and manufacture, DataSafe HXmonoblocs have been specifically developed for high discharge and BenefitsSpecifically developed for UPS applications6 & 12 volt monoblocs23 to 780 Watts/cell sizes(15 min.)

The DataSafe®HX range of valve regulated lead acid batteries has been designed to offer superior solutions for the Uninterruptible Power Supply (UPS) and …

Tags:

  Ranges, Summary, Battery, Enersys, Battery range summary

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Battery Range Summary - EnerSys - EMEA

1 The DataSafe HX Range of valve regulated lead acid batteries hasbeen designed to offer superior solutions for the UninterruptiblePower Supply (UPS) and Information Technology markets. DataSafeHX batteries are the ideal source of power to protect vital systemsand incorporates select design features that maximise reliability whileensuring superior performance and an excellent service HX batteries are designed using proven gas recombinationtechnology that removes the need for regular water addition bycontrolling the evolution of hydrogen and oxygen during use of gas recombination technology for lead acid batteries hastotally changed the concept of standby power. This technologyprovides the user with the freedom to use lead acid batteries in awide Range of on advanced electrochemistry and backed by over 100 yearsexperience in Battery technology and manufacture, DataSafe HXmonoblocs have been specifically developed for high discharge and BenefitsSpecifically developed for UPS applications6 & 12 volt monoblocs23 to 780 Watts/cell sizes(15 min.)

2 Rate to at 25 C)High power densityOptimum footprint and volume efficiencyLong design lifeProven VRLA AGM technologyVisit us at - June 2015 Battery Range Summary Construction Electrochemistry optimised for high ratedischarge applications High performance positive plate gridsdesigned to resist corrosion, prolong activelife and for efficient recharge Negative plates provide perfect balance withthe positive plates to ensure optimumrecombination efficiency Separators in low resistance microporousglass fibre. The electrolyte is absorbed withinthis material, preventing acid leakage in caseof accidental damage Containers and lids in highly resistantpolymer Electrolyte - high grade dilute sulphuric acidabsorbed into separator material High integrity terminals designed formaximum conductivity High integrity, leak-resistant post seal designfor long life Self regulating pressure relief valves -prevent ingress of atmospheric oxygenInstallation & Operation Monoblocs are designed to be installed ontheir base.

3 Consult your local EnerSys representative before installing in any otherorientation Recommended float charge - at 25 C Operating temperature Range :-20 C to +50 C (20 C - 25 C recommended) Up to six months shelf lifeStandards UL listing: file numbers MH16464 for 12HX25- 12HX150 and MH12544 for 12HX205 -6HX800 Classified as Long Life (> 10/12 years)according to Eurobat guide 2015 Approved for shipping as non-hazardous,non-spillable - per IATA Special Provision A67and 49 CFR The management system governing themanufacture of DataSafe HX products isISO 9001 No. EN-HX-RS-014 - June 2015 EnerSys World Headquarters 2366 Bernville Road, Reading, PA 19605, USA Tel: +1-610-208-1991 / +1-800-538-3627 EnerSys EMEA EH Europe GmbH, L wenstrasse 32, 8001 Zurich, Switzerland EnerSys Asia 152 Beach Road, Gateway East Building #11-03, Singapore 189721 Tel: +65 6508 1780 2015 EnerSys . All rights and logos are the property of EnerSys and its affiliates, except ISO, which is not the property of EnerSysSubject to revisions without prior notice.

4 General SpecificationsTerminal DrawingsL W L W L W L W Faston Tab: 250M5M6 Female ThreadC1432 Terminal LayoutsWatts/CellNominalShort MaximumDataSafe HX Nominal(Wpc)Capacity (Ah)TypicalCircuitDischargeInternalBatte ryVoltage 15 C10 WeightCurrent Current Resistance Terminal TerminalType(V)at 25 Cat 25 CLength Width Height(kg)(A)(Amps-2 min rate)(m )Layout 70 107 65 100 50 99 76 167 175 125 130 169 165 170 140 206 175 208 173 213 173 211 173 273 173 273 173 211 Dimensions (mm)