Example: barber

Battery Replacement Installation ... - Rockwell Automation

Installation InstructionsOriginal InstructionsBattery ReplacementCatalog Number 2711P-RY2032 Summary of ChangesThis publication contains new and updated information as indicated in the following PageSummary of Changes1 Important User Information2 Precautions3 About This Publication4 Replace Battery in PanelView Plus Terminals4 Replace Battery in PanelView Component Terminals6 Replace Battery in PanelView plus 6 and PanelView Plus 6 Compact Terminals7400 and 600 Terminals7 Replace Battery in PanelView Plus 6 Compact Terminals81000 Terminals8 Replace Battery in PanelView Plus 7 Standard Terminals10 Replace Battery in PanelView Plus 7 Performance Terminals, PanelView

Battery Replacement Catalog Number 2711P-RY2032 Summary of Changes This publication contains new and updated information as indicated in the following table. ... This perchlorate warning only applies to primary Lithium Manganese Dioxide (LiMnO2) cells or batteries, and products that contain these cells or batteries, sold or distributed in ...

Tags:

  Automation, Dioxide, Battery, Rockwell automation, Rockwell, Manganese, Manganese dioxide

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Battery Replacement Installation ... - Rockwell Automation

1 Installation InstructionsOriginal InstructionsBattery ReplacementCatalog Number 2711P-RY2032 Summary of ChangesThis publication contains new and updated information as indicated in the following PageSummary of Changes1 Important User Information2 Precautions3 About This Publication4 Replace Battery in PanelView Plus Terminals4 Replace Battery in PanelView Component Terminals6 Replace Battery in PanelView plus 6 and PanelView Plus 6 Compact Terminals7400 and 600 Terminals7 Replace Battery in PanelView Plus 6 Compact Terminals81000 Terminals8 Replace Battery in PanelView Plus 7 Standard Terminals10 Replace Battery in PanelView Plus 7 Performance Terminals, PanelView 5500 Terminals, PanelView 5510 Terminals.

2 And PanelView 5310 Terminals11 Replace Battery in ArmorView Plus 7 Terminals13 Replace Battery in PanelView 800 Terminals15 Additional Resources17 Topic PageAdded the ArmorView Plus 7 terminal to the list of instructions on how to replace the Battery in ArmorView Plus 7 the Additional Resources table with the Installation instructions for the ArmorView Plus 7 Automation Publication 2711P-IN009K-EN-P - March 2019 Battery ReplacementImportant User InformationRead this document and the documents listed in the additional resources section about Installation , configuration, and operation of this equipment before you install, configure, operate, or maintain this product.

3 Users are required to familiarize themselves with Installation and wiring instructions in addition to requirements of all applicable codes, laws, and including Installation , adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be no event will Rockwell Automation , Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this examples and diagrams in this manual are included solely for illustrative purposes.

4 Because of the many variables and requirements that are associated with any particular Installation , Rockwell Automation , Inc. cannot assume responsibility or liability for actual use based on the examples and patent liability is assumed by Rockwell Automation , Inc. with respect to use of information, circuits, equipment, or software described in this of the contents of this manual, in whole or in part, without written permission of Rockwell Automation , Inc., is this manual, when necessary, we use notes to make you aware of safety may also be on or inside the equipment to provide specific : Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic : Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.

5 Attentions help you identify a hazard, avoid a hazard, and recognize the information that is critical for successful application and understanding of the HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death.

6 Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Rockwell Automation Publication 2711P-IN009K-EN-P - March 20193 Battery ReplacementPrecautionsPerchlorate material special handling may apply. See perchlorate warning only applies to primary Lithium manganese dioxide (LiMnO2) cells or batteries, and products that contain these cells or batteries, sold or distributed in California, products contain a sealed lithium Battery which may need to be replaced during the life of the product.

7 At the end of its life, the Battery that is contained in this product should be collected separately from any unsorted municipal collection and recycling of batteries helps protect the environment and contributes to the conservation of natural resources as valuable materials are : There is a danger of explosion if the lithium Battery or real-time clock module in this product is incorrectly placed. Replace the Battery only with the indicated type. Do not replace the Battery or real-time clock module unless power has been removed or the area is known to be not dispose of the lithium Battery or real-time clock module in a fire or incinerator.

8 Dispose of the Battery in accordance with the local regulations. For safety information on the handling of lithium batteries. including handling and disposing of leaking batteries, see Guidelines for Handling Lithium Batteries, publication : The Battery or real-time clock module in these products must only be changed in an area known to be T E N T I O N: Work in a static-free environment and wear a properly grounded electrostatic discharge (ESD) careful when touching any of the exposed electronic components to prevent damage from Automation Publication 2711P-IN009K-EN-P - March 2019 Battery ReplacementAbout This PublicationThis document provides information on how to replace the lithium Battery , catalog number 2711P-RY2032, in these devices.

9 2711P PanelView Plus, 700 to 1500 terminals 2711C PanelView Component, C400, C600, and C1000 terminals 2711P PanelViewPlus 6, 400 and 600 terminals 2711PC PanelView Plus 6, Compact 400, 600, and 1000 terminals 2711P PanelView Plus 7, Standard terminals 2711P PanelView Plus 7, Performance terminals 2711P ArmorView Plus 7 terminals 2711P PanelView 5500 terminals 2715P PanelView 5510 terminals 2713P PanelView 5310 terminals 2711R PanelView 800 terminalsReplace Battery in PanelView Plus TerminalsFollow these steps to replace the Battery in the logic module of any PanelView Plus terminal with a 700 to 1500 power from the all power and communication the communication module, if attached, from the logic module by removing the four only Replacement Battery catalog number 2711P-RY2032.

10 Or an equivalent CR2032 lithium coin cell Battery , in these ModuleCommunication ModuleScrewCaptive ScrewDisplay ModuleRockwell Automation Publication 2711P-IN009K-EN-P - March 20195 Battery the captive screws that secure the logic module to the display module and carefully lift the logic module away from the back of the the Battery on the circuit the Battery by lifting the side of the the new Battery with the positive polarity (+) facing the logic module by aligning the logic module connector with the connector on the display down on the logic module until it is firmly the captive screws that secure the logic module to the display module to a torque value of N m ( lb in).