BCE5 EPRODUCT SPECIFICATIONSCOMPACT AIR HANDLERFORM NO. BCE5E-100 (03/2020)APPLICATION 2 - 5 ton systems Sequenced for demand management External access to heater circuit breakers INSTALLATION One piece design Smaller profile for tight application areas Multiposition - Factory ready for upflow, downflow, and horizontal left/right applications Approved for installation in manufactured housing and mobile homes CABINET Foil faced insulation for enhanced indoor air quality Double hemmed technology for increased structural rigidity Improved gasketing on doors to reduce air leakage Filter rack with thumb screws for easy access and removal Polymer plugs on drain locations for easy installation Baked polyester paint finished over galvanized steel for maximum durability High-strength, UV and heat resistant polymer drain pan designed for corrosion resistance Antimicrobial polymer drain pan built to resist mold and mildew growth 2% or less air leakageCOILS Omniguard total corrosion protection technology designed coil Enhanced tube-and-fin coil design featuring MHT Technology Lanced fins for maximum heat transfer Factory leak tested and pre-charged with nitrogen holding chargeCOMPONENTS Efficient Constant Torque blower motors Standard transformer and blower relay Field installed 5 - 20kW electric heat kits with easy plug connections Blower time delay for increased efficiency Sleeves on distributor tubing to

For the latest AHRI system matches, please visit www.alliedratings.com or www.AHRIdirectory.org Page 1. CPA AIR HAR BCE5 Page 2 MODEL NUMBER GUIDE REVISION NUMBER 50 = OMNIGUARD COIL ... 2 Matched with 1.5 ton condensing unit 750 650 610 550 480 3 Nominal 2 ton match without electric heat 950 825 785 740 690

Tags:

  Hari

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BCEE - Scene7

1 BCE5 EPRODUCT SPECIFICATIONSCOMPACT AIR HANDLERFORM NO. BCE5E-100 (03/2020)APPLICATION 2 - 5 ton systems Sequenced for demand management External access to heater circuit breakers INSTALLATION One piece design Smaller profile for tight application areas Multiposition - Factory ready for upflow, downflow, and horizontal left/right applications Approved for installation in manufactured housing and mobile homes CABINET Foil faced insulation for enhanced indoor air quality Double hemmed technology for increased structural rigidity Improved gasketing on doors to reduce air leakage Filter rack with thumb screws for easy access and removal Polymer plugs on drain locations for easy installation Baked polyester paint finished over galvanized steel for maximum durability High-strength, UV and heat resistant polymer drain pan designed for corrosion resistance Antimicrobial polymer drain pan built to resist mold and mildew growth 2% or less air leakageCOILS Omniguard total corrosion protection technology designed coil Enhanced tube-and-fin coil design featuring MHT Technology Lanced fins for maximum heat transfer Factory leak tested and pre-charged with nitrogen holding chargeCOMPONENTS Efficient Constant Torque blower motors Standard transformer and blower relay Field installed 5 - 20kW electric heat kits with easy plug connections Blower time delay for increased efficiency Sleeves on distributor tubing to protect tubesWARRANTY10 year limited warranty on all parts, extended warranty available* *Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty).

2 Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at for terms, conditions, and : For the latest AHRI system matches, please visit or 1 COMPACT AIR HANDLER BCE5 EPage 2 MODEL NUMBER GUIDEREVISION NUMBER50 = OMNIGUARD COILMETERING DEVICE4X = R410A TXVVOLTAG EA = 208/230V - 1 PHASE - 60 HZPOSITIONM = MULTI-POSITIONTONNAGE24, 30, 36, 42, 48, 60 PRODUCTBC= BLOWER COILFE ATU RE SETE = ENHANCED FEATURESSERIES5 = 5 SERIES (1 PIECE PLATFORM, OMNIGUARDTM)MOTOR & CONTROL C = PSCE = CONSTANT TORQUEV = VARIABLE SPEEDBC E 5 E 24 M A 4X - 50BC E 5 E 24 M A 4X - 50 PHYSICALM odelVolts/Hz/PhaseMax. Elec. Heat (kW)Transformer Size & TypeFilter Size (in.)Refrigerant ConnectionInstalled TXV SizeWeight (lbs.)Suction (in.)Liquid (in.)BCE5E24208-230/60/11040 VA Class 215 x 203/43/8H4 TXV01127 BCE5E30208-230/60/11540 VA Class 215 x 203/43/8H4 TXV01133 BCE5E36208-230/60/11540 VA Class 218 x 207/ 83/8H4 TXV02163 BCE5E42208-230/60/11540 VA Class 218 x 207/ 83/8H4 TXV02168 BCE5E48208-230/60/12040 VA Class 218 x 207/ 83/8H4 TXV02186 BCE5E60208-230/60/12040 VA Class 218 x 207/ 83/8H4 TXV03186 Cabinet0 in.

3 (0 mm)To Plenum0 in. (0mm)To Outlet Duct within 3 ft. (914mm)0 in. (0 mm)Floor0 in. (0 mm) See Note #1 Service / MaintenanceSee Note #21 Units installed on combustible floors in the downflow position with electric heat require optional downflow combustible flooring base. 2 Front service access - 24 in. (610 mm) minimum. Note - If cabinet depth is more than 24 in. (610mm), allow a minimum of the cabinet depth plus 2 in. (51 mm).INSTALLATION CLEARANCES WITH ELECTRIC HEATCOMPACT AIR HANDLER BCE5 EPage 3 ACCESSORIESELECTRIC HEATD escriptionWhere UsedKit NumberDownflow Kit24, 30Y965836, 42, 48, 60Y9659 Downflow Combustible Floor Base Kit24, 3012W9536, 42, 48, 6012W96 Horizontal Support Frame kitAll Models56J18 Side Return Unit Stand (upflow only)All Models45K32 Single Point Power KitAll Models21H39 Wall Hanging Bracket Kit (upflow only)All Models45K30 Electric Heat Kits with Terminal BlockSizeModelC/B Size *Where UsedCat #5 kWECBA25-5NA24, 30, 36, 42, 48, , 30, 36, 42, 48, 6016Y3710 kWECBA25-10NA24, 30, 36, 42, 48, 6016Y38 Electric Heat Kits with Circuit Breaker5 kWECBA25-5CB30A24, 30, 36, 42, 48, , 30, 36, 42, 48, 6016Y4110 kWECBA25-10CB60A24, 30, 36, 42, 48, + 25A30, 36, 42, 48, 6016Y4315 kWECBA25-15CB60A + 25A30, 36, 42, 48, 6016Y4420 kWECBA25-20CB60A + 50A48, 6016Y46 Replacement Circuit Breakers (2 pole)

4 VoltsSizeCat #208/240V- 1 phase25A41K1330A17K7035A72K0740A49K1445A 17K7150A41K1260A17K72* Circuit breaker must match rated Max C/B Size ; replace breaker as AIR HANDLER BCE5 EPage 4 ELECTRICALM odelHeating Capacity (240V)Blower AmpsMin. Circuit AmpacityMax. Circuit Breaker SizeSingle Point Power SupplyNominal Heater 57. 57. 57. 57. 57. 57. 57. For 208 volt use .751 correction factor for kW and Btuh2. , 15 and 20kW (2 stage models) require 2 supply circuits3. Circuit #1 includes blower motor amps except 20kW modelsCOMPACT AIR HANDLER BCE5 EPage 5 BLOWERM odelMotor Size (hp)Blower Size (in.)Speed Ta pApplicationCFM @ ESP - in. x 81 Fan Only5905755304804302 Matched with ton condensing unit7506506105504803 Nominal 2 ton match without electric heat 9508257857406904 Nominal 2 ton match with electric heat 104010209859409205 High static application11601140112010801050 BCE5E301/210 x 81 Fan Only7006656255654902 Matched with 2 ton condensing unit8608107707156653 Nominal ton match without electric heat 104010109809408904 Nominal ton match with electric heat 11401100104510159805 High static application13901375134012851245 BCE5E361/210 x 81 Fan Only8508007506656002 Matched with ton condensing unit10809509108507753 Nominal 3 ton match without electric heat 127012301170112010604 Nominal 3 ton match with electric heat 144014001330128012405 High static application15401475143013801300 BCE5E423/412 x 101 Fan Only9909158608107252 Matched with 3 ton condensing unit119011501100106010203 Nominal ton match without electric heat 139013501315128012304 Nominal ton match with

5 Electric heat 166516251585155015105 High static application17501710167516401600 BCE5E48112 x 101 Fan Only125012101185113011102 Matched with ton condensing unit150014651435140013603 Nominal 4 ton match without electric heat 171516701635161515754 Nominal 4 ton match with electric heat 177017351700167016505 High static application18951860183517951760 BCE5E60112 x 101 Fan Only1100105010009258302 Matched with 4 ton condensing unit162515951565152014903 Nominal 5 ton match without electric heat 181517851760173016854 Nominal 5 ton match with electric heat 190518701835181017655 High static application19801955192518951860 All data given while air handler is operating with a wet coil and without air filter tap 1 to be used for continuous fan tap 2 to be used for cooling speed of 1/2 ton smaller outdoor unit match. Speed tap 3 to be used for cooling speed of nominal tonnage tap 4 to be used for heating speed for units with electric heat. This is the minimum speed for heating.

6 Speed tap 5 to be used for high static AIR HANDLER BCE5 EPage 6 DIMENSIONS (IN.)ABFRONT VIEWSIDE VIEWLINE VOLTAGEINLETS(Top and Right Side)LOW VOLTAGEINLETS(Either Side)SUCTIONLINELIQUIDLINEFILTERACCESS3/ 4(19)AIR FLOWCIRCUITBREAKERCOVERD 1-1/8(29)1/2(13)CLINE VOLTAGEINLETS (Top and Left Side)LOW VOLTAGEINLETS(Top and Right Side)1 (25)SUPPLY AIROPENINGTOP VIEWOPENINGOPENING1 (25)1 (25)1-1/8(29)1-1/8(29)20-3/8(518)22(559) 14-1/2(368)DETAIL OF PIPING PLATELIQUIDLINECONDENSATEDRAINS (2)(Horizontal)1-3/4(44)3/4 (19)2-3/4(70)3-1/2(89)PIPINGPLATE4-3/4(1 21)4-3/8(111)2-3/8(60)CONDENSATEDRAINS (2)(Upflow andDownflow)SUCTIONLINECONDENSATE DRAINPIPING PLATE (3)(2-1/4 x 3-3/4) specifications and illustrations subject to change without notice and without incurring AIR HANDLER BCE5 EFORM NO. BCE5E-100 (03/2020)Printed in the 2020 Allied Air Enterprises LLC, a Lennox International Inc.

7 Company1-800-448-5872 All specifications and illustrations subject to change without notice and without incurring 7