ALL TAXES EXTRA. ALL PRICES FACTORY. LIST PRICES SHOWN IN SUBJECT TO CHANGE WITHOUT NOTICE. WE RESERVE THE RIGHT TO CORRECT PRICING CENTRIFUGAL PUMPS AND ACCESSORIES 2017 LIST PRICESB1525P EFFECTIVE: JANUARY 1, 2017 SUPERSEDES ALL PREVIOUS PRICE LISTS2B1525P (11/22/16)TABLE OF CONTENTS Page General InformationOrdering Information 3 Certified Test Charges 3 Pump Model Nomemclature 4 Small Stainless Centrifugals SSCX Stainless Steel CENTRIFUGAL PUMPS 5 C Single-Stage Motor Drive 7 SSHM-2 Horizontal Multi-Stage PUMPS 7 Type B Closed Coupled CentrifugalsElectric Motor DriveT Series, 6 Nominal Impeller Diameter 8W Series, 7 Nominal Impeller Diameter 11Z Series, 9 Nominal Impeller Diameter 12E Series, 10 Nominal Impeller Diameter 18G Series, 12 Nominal Impeller Diameter 20J Series, 13 Nominal Impeller Diameter 22EX Series, 15 , EY Series.

3 B1525P (11/22/16) PRODUCT AND ORDERING INFORMATION Certified Pump Testing Electric Motor Drive Centrifugal Pumps The following information is …

Tags:

  Pumps, Centrifugal, Centrifugal pump, Berkeley, Berkeley centrifugal pumps and

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of BERKELEY CENTRIFUGAL PUMPS AND …

1 ALL TAXES EXTRA. ALL PRICES FACTORY. LIST PRICES SHOWN IN SUBJECT TO CHANGE WITHOUT NOTICE. WE RESERVE THE RIGHT TO CORRECT PRICING CENTRIFUGAL PUMPS AND ACCESSORIES 2017 LIST PRICESB1525P EFFECTIVE: JANUARY 1, 2017 SUPERSEDES ALL PREVIOUS PRICE LISTS2B1525P (11/22/16)TABLE OF CONTENTS Page General InformationOrdering Information 3 Certified Test Charges 3 Pump Model Nomemclature 4 Small Stainless Centrifugals SSCX Stainless Steel CENTRIFUGAL PUMPS 5 C Single-Stage Motor Drive 7 SSHM-2 Horizontal Multi-Stage PUMPS 7 Type B Closed Coupled CentrifugalsElectric Motor DriveT Series, 6 Nominal Impeller Diameter 8W Series, 7 Nominal Impeller Diameter 11Z Series, 9 Nominal Impeller Diameter 12E Series, 10 Nominal Impeller Diameter 18G Series, 12 Nominal Impeller Diameter 20J Series, 13 Nominal Impeller Diameter 22EX Series, 15 , EY Series.

2 18 Nominal Impeller Diameters 25 Electric Self Priming 26 Seal Adders 26 Standard Motor Adders 27 Electric Motor Drive Replacement Motors 28 Pentek Intellidrive XL 30 PPX Three Phase Pump Panels 38 Type B Frame MountHydraulic, Belt and Coupling Drives Frame Mount & Self-PrimingZ Series, 9 Nominal Impeller Diameter 39E Series, 10 Nominal Impeller Diameter 42G Series, 12 Nominal Impeller Diameter 43J Series, 13 Nominal Impeller Diameter 44EX Series, 15 Nominal Impeller Diameter 45EY Series, 18 Nominal Impeller Diameter 45 PageType B SAE Engine Mount For Flywheel HousingsSAE CENTRIFUGAL pumpsZ Series, 9 Nominal Impeller Diameter 46E Series, 10 Nominal Impeller Diameter 47G Series, 12 Nominal Impeller Diameter 48J Series, 13 Nominal Impeller Diameter 49EX Series, 15 Nominal Impeller Diameter 50XT Series, Nominal Impeller Diameter 51EY Series, 18 Nominal Impeller Diameter 51 SAE Self-Priming 52 SAE Flywheel Couplings 52 Type B Air Cooled (Gas) PumpsAir-Cooled Engine Drives End Suction 53 Air-Cooled Engine Drives Self-Priming 53 Wastewater/Trash PumpsB-AG Series Submersible 54 AccessoriesFlange Kits and Impeller Cutting Charges 55 Discharge Priming Valves 56 NEW!

3 B1525P (11/22/16)3 PRODUCT AND ORDERING INFORMATIONC ertified Pump TestingElectric Motor Drive CENTRIFUGAL PUMPS The following information is required with each Pump Model Number2. Motor Horsepower3. Catalog Number4. Impeller Diameter5. Required Flow Rate, Head and RPM6. Optional Flow Rate, Head and RPMCONNECTION OPENINGS Suction and Discharge openings are NPT tapped for standard pipe, or faced and drilled per ANSI , class 125 for standard flanges as indicated. Maximum working pressure for class 30 cast iron, per ANSI , is 175 PSI unless otherwise stated on pump curve. List price for cast iron companion flanges includes threaded flange for standard pipe, gaskets, bolts and nuts, and can be found on page INCLUDE Assembed pump and motor. BASIC PUMP AND MOTOR Pump end and bracket assembled on standard horizontal close-coupled reserves the right to use the motor manufacturer of its choice.

4 Units specified (ordered) with specific motor manufacturer maybe subject to additional charges and lead factory for TEFC motors not listed on price sheets. Part-wind start motors are available. Consult factory for delivery VOLTAGESS ingle-phase motors showing both 115 and 230 volts, and three-phase motors showing both 230 and 460 volts as standard, are reconnectable for either voltage, 230 volt motors WILL NOT operate on 208 volt systems. For 208 volt systems, order 200 volt motor. **200V motors subject to additional CASES All pump cases are cast All brackets are cast Cast iron and bronze (see price sheet). Pricing for special impeller trims is listed on page SEALS Seal materials are ceramic carbon, Buna-N, and 300 Series stainless steel generally suitable for water to 200 F. All models ending with the letter S are fitted with mechanical shaft seal.

5 Special seals may be available, consult factory. Stuffing box is standard on all other Fiber-metallic packing is used in stuffing box models. For special pumping applications (liquids other than water), consult RINGS All wear rings are SLEEVES All shaft sleeves are stainless CONSTRUCTION AND MATERIALSALL IRON List price additions for all-iron construction include cast iron bracket, cast iron case, cast iron impeller, packing gland, cast iron wear ring (where used), stainless steel shaft sleeve, and corrosion-resistant bolts, nuts and Items of equipment frequently required to complete the pump installation may be ordered separately from sections of the catalog ORIENTATIONHPP hase115V200V**230V460V575V1 thru 1-1/21availableavailablestandardrefer to factory2 thru 101N/Aavailablestandardrefer to factory1 thru 403N/Aavailablestandardstandard available50 thru 2003N/Aavailableavailablestandard availablePerformance TestsNet PricePart NumberDescriptionCTEST01 Non-Witnessed Performance Test with no NPSH$900 NETCTEST02 Customer Witnessed Performance Test with no NPSH TestCTEST03 Non-Witnessed Performance with 1 Point NPSH TestCTEST04 Customer Witnessed Performance with 1 Point NPSH TestCTEST05 Non-Witnessed Certified Hydrostatic Test$129 NETCTEST06 Witnessed Certified Hydrostatic Te stNOTES.

6 Certified tests shall be factory laboratory tests conducted in accordance with the edition of ANSI/HI and ANSI/HI test standards. Test will be evaluated to Level B requirements. If the measured performance is within -3% to +5% of the published rating point or the customer specified rating point, the pump will be shipped along with the documentation. The factory reserves the right to modify the impeller diameter in order to meet the published or customer specified rating point. Head Capacity at the pump casing discharge and amperage draw by the motor will be provided on the certified performance curve. Power available for testing is 230/1/60, 230/460/3/60, 600/3/60. Customer s power requirements must match factory s power available. PUMPS will be tested at synchronous motor speed. All PUMPS are NPSH tested using vacuum tank suppression. For certified testing of frame mount, SAE and air-cooled engine drive PUMPS , please contact factory.

7 Pump will be shipped to location specified on Customer Purchase Order within 24-48 hours from testing completion in Pentair Delavan Lab and receipt of customer approval of test results. Pump(s) will not be held in Lab after this period. A copy of the pump tests will be provided to the fax number on the Customer s Purchase fromthis directionViewed fromthis directionPump with aClockwiseRotationPump with aCounter-ClockwiseRotation(Standard Option on Frame Mount)Clockwise rotation As viewedAs viewedCounter-Clockwise 1263912639 RotationVolute Orientation (viewed from driver end of pump)ClockwiseT1T2 (Default)T3T4 Counterclockwise (Std. option on frame mount)4B1525P (11/22/16)TYPE B PUMP MODEL NOMENCLATURE B 4 G P B H SType Of ConstructionB="Back Pull-Out" DesignDischarge Size (Inches)Nominal Impeller Diameter (Inches)3" = A7" = W 11" = F15" = EX18" = EY4" = M8" = Y12" = G " = XT19" = EZ5" = X9" = Z13" = J16" = ET20" = EE6" = T10" = E14" = N17" = EWType of DriveP = Electric Motor - Pump Attached Directly to Motor FrameQ = Engine Drive - Pump Attached Directly to Engine FrameR = Frame Mounted Belt or Flexible Coupling DriveRM = Special Duty Mounting FrameSpecial Features (Optional)B = Hydraulically Balanced Impeller DesignK = Self-PrimingRelative Capacity of ImpellerLL = Very LowL = LowM = Medium (Often Omitted)H = HighHH = Very HighNumber Of Stages (Optional)(Single stages not indicated)Shaft Seal (Optional)S = Mechanical Seal (Packed Stuffing Box is not indicated)

8 Horsepower of Motor or Engine (Normally indicated on Engine Driven PUMPS only)B 4 G P B H 2 S 10 4" x 6" x 13" B H Discharge Size (Inches)Suction Size (Inches)Nominal Impeller Diameter (Inches)3" = A7" = W 11" = F15" = EX18" = EY4" = M8" = Y12" = G " = XT 19" = EZ5" = X9" = Z13" = J16" = ET20" = EE6" = T10" = E14" = N17" = EWSpecial Features (Optional)B = Hydraulically Balanced Impeller DesignRelative Capacity of ImpellerLL = Very LowL = LowM = Medium (Often Omitted)H = HighHH = Very High4" 6" 13" B H The model configurations above illustrate the complete range of closed coupled product identification PLATE EXAMPLE: PUMP SIZE EXAMPLE: B1525P (11/22/16)5 SMALL STAINLESS CENTRIFUGALSB erkeley SSCX SeriesElectric Motor Drive, Noryl ImpellerModel SizeDischarge SizeCatalog PriceWeight (lbs)SS1XN-1 21/2115/230-1 ODP1-1/4 1 B78635$770 22230/460-3B78636 789 26115/230-1 TEFCB78647 989 32230/460-3B78648 1,005 29SS1XN-3 43/4115/230-1 ODP1-1/4 1 B78637 837 25230/460-3B78638 860 23115/230-1 TEFCB78649 1,053 37230/460-3B78650 1,105 32SS1XN-11115/230-1 ODP1-1/4 1 B78639 917 27230/460-3B78640 921 22115/230-1 TEFCB78651 1,109 40230/460-3B78652 1,162 35SS1XN-11 21-1/2230-1 ODP1-1/4 1 B78641 1,005 32230/460-3B78642 1,039 28230-1 TEFCB78653 1,244 50230/460-3B78654 1,297 37SS11 4XN-22230-1 ODP1-1/2 1-1/4 B78643 1,269 36230/460-3B78644 1,185 31230-1 TEFCB78655 1,375 52SS11 4XN-2-1/22-1/2230-1 ODP1-1/2 1-1/4 B78645 1,412 37230/460-3B78646 1,396 33 The standard seal in a SSCX series pump with a Noryl Impeller is a Buna-Carbon/Ceramic.

9 The volute uses a Buna O-Ring to seal the pumping chambers. Use the Seal Options below to upgrade your seal Seal OptionsSeal FacesElastomers Mechanical Seal & Pump Volute ODP and TEFCSS_XN Seal Adder List PriceCarbon / CeramicBunaIncludedCarbon / CeramicViton$64 Carbon / Silicon CarbideViton 113 Silicon CarbideViton 170 6B1525P (11/22/16)SMALL STAINLESS CENTRIFUGALSB erkeley SSCX SeriesElectric Motor Drive, Stainless Steel ImpellerModel SizeDischarge SizeCatalog PriceWeight (lbs)SS1XS-3 43/4115/230-1 ODP1-1/4 1 B82411$960 25230/460-3B82412 1,015 23115/230-1 TEFCB82413 1,136 37208-230/460-3B82414 1,189 32SS1XS-11115/230-1 ODPB82415 1,032 27230/460-3B82416 1,086 22115/230-1 TEFCB82417 1,196 40208-230/460-3B82418 1,248 35SS1XS-11 21-1/2230-1 ODPB82419 1,175 32230/460-3B82420 1,115 28230-1 TEFCB82421 1,336 50SS1XS-22230-1 ODPB82423 1,336 36230/460-3B82424 1,244 31SS1XS-21 22-1/2230-1 ODPB82427 1,478 37230/460-3B82428 1,464 33 The standard seal in a SSCX series pump with a Stainless Steel Impeller and ODP motor is Viton-Carbon/Ceramic.

10 For TEFC equipped PUMPS a Viton-Silicon Carbide seal is included. Use the Seal Options below to upgrade your seal Seal OptionsSeal FacesElastomers Mechanical Seal & Pump Volute With ODP MotorWith TEFC MotorSS_XS Seal Adder List PriceSS_XS Seal Adder List PriceCarbon / / Silicon CarbideViton$ = Not availableB1525P (11/22/16)7 SMALL STAINLESS CENTRIFUGALSB erkeley C SeriesElectric motor drive, cast iron construction, silicon bronze impellerModel NumberHPODP Single-Phase 230 VODP Three-Phase 230/460 VWeight Working Pressure (PSI)Suction Dimensions (in.)Discharge Dimensions (in.)Catalog NumberList PriceCatalog NumberList PriceC1-1/4 TPMS3B53602S$2,111 B53603S$2,100 551101-1/2 NPT1-1/4 NPTC1-1/2 TPHS3B59212S 2,264 B59213S 1,941 561102 NPT1-1/2 NPTC2 MPS3B53616S 2,202 B53617S 2,097 551002-1/2 NPT2 NPTB erkeley SSHM-2 Horizontal Multi-Stage PUMPS Electric Motor Drive, Self-PrimingHPVoltage/PhaseCatalog PriceWeight (lbs)Max.