Transcription of Carlon Flexible Raceway Systems
1 Plenum-Gard Riser-Gard Hal-FreeRiser-Gard GeneralPurposeCarlon FlexibleRaceway Gross Automation (877) 268-3700 Plenum-Gardis aUL Listed non-metallic corrugated Flexible conduitfor use in Plenum, Riser and GeneralPurpose is manufactured from PVDF resin, which is extremelydurable and resistant to abrasion and mechanical damage before/aftercable is listed to UL 2024 inaccordance with the National ElectricalCode for Plenum, Riser, GeneralPurpose, and other cabling optical fiber/telecommunication applications asdefined in Articles 725, 770, 800 and : Installed cables must beplenum rated and the UL Listingmust be printed on the cables MUST beremoved (Reference NEC).ULStandard 2024 ValueMaximum Flame Propagation5 Peak Optical Smoke Optical Smoke (F x W)TypeLength(lbs.)(lbs.)
2 OrangeCE4X1-1000 Empty36" x 24"W1000358 OrangeCE4X1-1000 SEmpty36" x 24"W1000358 OrangeCF4X1C-500900 " x 24"W5003510 OrangeCF4X1C-1000900 " x 32"W10009010 OrangeCF4X1C-1500900 " x 32"W15009010 OrangeCF4X1C-5200900 " x 41"W520026510 OrangeCF4X1C-6500900 " x 41"W650030210 OrangeCF4X1C-8000900 " x 41"W800037510 OrangeCG4X1C-500900 " x 24"W5003516 OrangeCG4X1C-900900 " x 32"W9009016 OrangeCG4X1C-1600900 " x 46"W160010516 OrangeCG4X1C-3200900 " x 41"W320026516 OrangeCG4X1C-6500900 " x 41"W650070016 OrangeCG4X1-900 SEmpty48" x 32"W9009016 OrangeCH4X1C-350900 " x 32"W3509020 OrangeCH4X1C-1200900 " x 46"W120010520 OrangeCH4X1C-4000900 " x 41"W400037520 OrangeCJ4X1C-225900 " x 32"W2259023 OrangeCJ4X1C-700900 " x 46"W70010523 OrangeCJ4X1C-2000900 " x 41"W200037523 OrangeCJ4X1C-2800900 " x 41"W2800375231"2"11/4"3/4"11/2"Standard Stock Reels Storage -4 F to 158 F Handling -4 F to 104 F No UV protection (not suitable for outdoor use) Do NOT store outsideW =WoodApplications:Plenum, Riser,and General PurposeTechnical Info:NEW1/2"&3/4"with tapeGross Automation (877) 268-3700 Features:Specifications For use in Plenum areas per Articles 725, 770, 800 and 820.
3 Sizes 1/2" through 2" Pre-installed pull tape available in sizes 1/2" through 2" Outside Diameters meet IPSD imensions UL Listed Raceway meeting UL 2024 Footage sequentially marked Single peak designCustom OrdersHow to Build a Part NumberPosition 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 ProductSizeConfigurationWallColorPull LineLengthC =Plenum-GardD =1/2"4 =CorrugatedX = Standard1 = OrangeC = 900 lb. TapeExampleE =3/4"2 = Black-1000 = FeetF =1"3 = Gray-1000S = 1000 Feet SplitG = 11/4"4 = WhiteH = 11/2"5 = BlueJ =2"7 = Yellow8 =RedPullCoilWt. perColorPart (ft.)100 ft. (lbs.)OrangeCE4X1-350*Empty3508 OrangeCF4X1C-100*900 *900 *Empty25010 OrangeCG4X1C-200*900 *900 *900 Stock Coils1"2"11/4"3/4"11/2"* Overnight BendSizeMin. ". "3/4". "1" "11/4" "11/2" "2" " Custom Orders are not returnable Custom lengths are available in minimum order quantities of 1000 ft.
4 Custom colorruns are available in minimum order quantities of 10,000 : Color: Black, Blue, Gray, Red, White and Yellow Two, three, or four way parallel Split Duct Custom print lineGross Automation (877) 268-3700 Riser-Gardis a nonmetallic Flexible Raceway for use in Riserand General Purpose is UL Listed and is available with tape is listed to UL 2024 Standard for Riser Applications or optical Listed to 2024 Test MethodMaximum ValueMaximum Flame PropagationUL Air Temperature at 12 2024372 perColorPart (F x W)TypeLength(lbs.)100 ft. (lbs.)OrangeDE4X1-1000 Empty36" x 24"W1000359 OrangeDF4X1C-500R900 " x 24"W5005014 OrangeDF4X1C-1000900 " x 32"W10009014 OrangeDF4X1C-1500900 " x 32"W15009014 OrangeDF4X1C-2700900 " x 46"W270010514 OrangeDF4X1C-5200900 " x 41"W520026514 OrangeDF4X1C-6500900 " x 41"W650030214 OrangeDF4X1C-7000900 " x 45"S700014814 OrangeDF4X1C-9400900 " x 45"S940019914 OrangeDG4X1C-900900 " x 32"W9009017 OrangeDG4X1C-500R900 " x 24"W5005017 OrangeDG4X1C-1500900 " x 46"W150010517 OrangeDG4X1C-1600900 " x 46"W160010517 OrangeDG4X1C-3200900 " x 41"W320026517 OrangeDG4X1C-4500900 " x 45"S450014817 OrangeDG4X1C-5600900 " x 46"W560060017 OrangeDG4X1C-6500900 " x 45"S650022017 OrangeDH4X1C-1200900 " x 46"W120010522 OrangeDH4X1C-4000900 " x 45"S400019322 OrangeDH4X1C-4500900 " x 45"S450019922
5 OrangeDJ4X1C-700900 " x 46"W70010526 OrangeDJ4X1C-2000900 " x 41"W200037526 OrangeDJ4X1C-2800900 " x 45"S2800199261"2"11/4"3/4"11/2"Standard Stock Reels Storage -4 F to 158 F Handling -4 F to 104 F No UV protection (not suitable for outdoor use) Do NOT store outsideW =Wood, S = SteelRiser-Gard is listed to UL 2024 in accor-dance with the National Electrical Code perArticles 725, 770, 800 and 820 for Riser,General Purpose, and other cabling opticalfiber/telecommunication is suitable for use in vertical runs in a shaft or between floors, as well as areas other than the : Installed cables must be of suitable rating for the RatedApplications:Riser and General PurposeTechnical Info:Gross Automation (877) 268-3700 Features: For use in Riser and General Purpose areas perArticles 725, 770, 800 and 820 of the NEC.
6 Riser-Gard is also suitable for direct approved for exposed : UL has notevaluated Riser-Gard for thisapplication. UL Listed Raceway meeting UL 2024 Available in sizes 3/4" through 2" Pull tape can be factory pre-installed in 1" through 2" Outside Diameters meet IPSD imensions Footage sequentially markedCustom OrdersHow to Build a Part NumberPosition 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 ProductSizeConfigurationWallColorPull LineLengthD =Riser-GardE =3/4"4 =CorrugatedX =Standard1 =OrangeC =900 lb. T apeExampleF =1"2 =Black-1000 = FeetG = 11/4"3 = Gray-1000S = 1000 Feet SplitH = 11/2"4 = WhiteJ =2"5 = Blue7 =Yellow8 =RedPullCoilProduct Wt. perColorPart (ft.)100 ft. (lbs.)OrangeDE4X1-350*Empty3509 OrangeDF4X1C-250*900 *Empty25014 OrangeDG4X1-200 Empty20017 OrangeDG4X1C-200*900 *Empty20017 OrangeDH4X1C-150*900 *900 Stock Coils1"2"11/4"3/4"11/2"* Overnight BendSizeMin.
7 ". "1". "11/4" "11/2" 1/4"2" 1/2" Custom Orders are not returnable Custom lengths are available in minimum order quantities of 1000 ft. Custom colorruns are available in minimum order quantities of 10,000 : Color: Black, Blue, Gray, Red, White and Yellow Two, three, or four way parallel Split Duct Custom print lineGross Automation (877) 268-3700 Riser-Gard Features:Hal-Free Riser-Gard is listed to UL2024 in accordance withNECA rticles 725, 770, 800 and lengths and split ducts are available upon Riser-Gard is available in white Listed to 2024 Test MethodMaximum ValueMaximum Flame PropagationUL 20243'6"Maximum Air TemperatureUL 2024387 FCustom OrdersHow to Build a PartNumberPosition 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 ProductSizeConfigurationWallColorPull LineLengthH =Hal-FreeF = 1"4 = CorrugatedX = Standard4 = WhiteC = 900 lb.
8 TapeExampleRiser-GardG = 11/4"-1000 = FeetH = 11/2"-1000S = 1000 Feet SplitJ =2" Free from halogen elements Compliant with NEC Articles 725,770, 800 and 820 Available in sizes 1" through 2" Available in white only Sequentially marked footageHal-Free Riser-Gardis ahalogen freenonmetallic Flexible Raceway for use inriser and general purpose the event of a fire, this product willnot release halogen elements into theair, which makes it ideal for applicationsin tunnels, laboratories and high-tech RatedApplications:Riser and GeneralPurpose Custom orders not returnable Custom lengths available in minimum order quantities of 1000 Info: Storage and Handling -4 F to 150 F No UV protection (not suitable for outdoor use) Do NOTstore outsideReelReelWt. (feet)(lbs.)(lbs.) " x 41" " x 41" " x 41" " x 41" Stock Reels1"2"11/4"11/2"W = WoodGross Automation (877) 268-3700 PurposeGeneral Purposeis nonmetallicflexible Raceway for use in GeneralPurpose applications only.
9 It is ULListed and available with tape Listed to 2024 Test MethodMaximum ValueMaximum Flame PropagationUL Air Temperature at 12 2024372 F Storage -4 F to 158 F Handling -4 F to 104 F No UV protection (not suitable for outdoor use) Do not store outsideGeneral Purpose Raceway is listed to UL2024in accordance with the National ElectricalCode per Articles 725, 770, 800 and 820 forGeneral Purpose and other cabling opticalfiber/telecommunication RatedApplications:General PurposeTechnical perColorPart (F x W)TypeLength(lbs.)100 ft. (lbs.) "82" x 41" "72" x 41" "82" x 41" "82" x 41"W2000375261"2"11/4"11/2"Standard Stock ReelsW = WoodFeatures: For use in General Purpose areas perArticles 725, 770, 800 and 820 of the NEC. Available in sizes 3/4" through 2" Pull tape can be factory pre-installed in 1" through 2" Outside Diameters meet IPS Dimensions Footage sequentially markedCustom OrdersHow to Build a PartNumberPosition 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 ProductSizeConfigurationWallColorPull LineLengthB =General PurposeF = 1"4 = CorrugatedX = Standard1 = OrangeB = 1130 lb.
10 TapeExampleG = 11/4"2 =Black-1000 = FeetH = 11/2"3 = GrayJ =2"4 = White5 =Blue7 =Yellow8 =Red Custom Orders are not returnable Custom lengths are available in minimum order quantities of 1000 ft. Custom colorruns are available in minimum order quantities of 10,000 : Color: Black, Blue, Gray, Red, White and Yellow Two, three, or four way parallel Split Duct Custom print lineGross Automation (877) 268-3700 Raceway Accessories For use with Riser-Gard and General PurposeNonmetallic Adapters & Couplings For use with Plenum-Gard Nonmetallic Adapters & CouplingsStandard CartonStandard CartonPart. (lbs.)SCA240E3/4" " CartonStandard CartonPart. (lbs.)SCA243E3/4" " AdaptersStandard CartonStandard CartonPart. (lbs.)SCA253E3/4" " AdaptersStandard CartonStandard CartonPart. (lbs.)