Transcription of Carlon Snap-N-Stac Combo Spacers
1 Carlon Snap-N-Stac . Combo Spacers Carlon Snap-N-Stac Combo Duct Spacers are specifically designed to replace the two-piece base and intermediate spacer system, by combining the conventional base and intermediate spacer into a single unit! Manufactured out of highly engineered thermoplastic material, Snap-N-Stac Spacers are strong, durable and Patent Pending able to withstand the rigors of concrete construction. They feature an innovative horizontal and EXCLUSIVE. Vertical locking system and can be used as either a Installations base or intermediate spacer. Snap-N-Stac Spacers are available in duct sizes 2", 3", 4", 5", and 6" and can be installed horizontally, vertically or turned up-right for unique duct bank configurations. This NEW one-piece design makes underground Horizontal Locking duct bank installations faster and easier than the conventional two-piece system saving material and labor costs.
2 Carlon Snap-N-Stac Combo IDEAL. Solution for Underground Duct Bank Installations. Features: Conventional Base and Intermediate Spacer in a Single Unit! EXCLUSIVE Vertical Locking System Vertical Interlocking With Reducer Horizontal Locking System Installs Horizontally or Turned Upright Molded-In Rebar Holder 5 Sizes: 2", 3", 4", 5", and 6". Reducer to Accommodate Smaller Duct Sizes Can Be Used as Either an Intermediate or Base Spacer Spacers Interlock Horizontally Regardless of Size Nonmetallic, Noncorrosive, Nonconductive Strong and Durable Free Standing Easy to Handle Fast Installation Innovative Solutions For Wire and Cable Management. Gross Automation (877) 268-3700 Specifications Part Number Description Std. Carton Qty. Std. Carton Wt. (lbs.). SP2W20-2 2" Two-Way Snap-N-Stac Spacer - 2" Separation 56 SP2W30-2 2" Two-Way Snap-N-Stac Spacer - 3" Separation 40 SP3W20-2 3" Two-Way Snap-N-Stac Spacer - 2" Separation 40 SP3W30-2 3" Two-Way Snap-N-Stac Spacer - 3" Separation 24 SP4W15-2 4" Two-Way Snap-N-Stac Spacer - 1-1/2" Separation 26 SP4W20-2 4" Two-Way Snap-N-Stac Spacer - 2" Separation 24 SP4W30-2 4" Two-Way Snap-N-Stac Spacer - 3" Separation 20 SP5W20-2 5" Two-Way Snap-N-Stac Spacer - 2" Separation 20 SP5W30-2 5" Two-Way Snap-N-Stac Spacer - 3" Separation 14 SP6W20-2 6" Two-Way Snap-N-Stac Spacer - 2" Separation 12 SP6W30-2 6" Two-Way Snap-N-Stac Spacer - 3" Separation 12 S287F 1" Snap-Loc Reducer 100 S287J 2" Snap-Loc Reducer 100 S28612 Beaded Strap 100 H o w t o I n t e r p re t t h e P a r t N u m b e r Position 1 Position 2
3 Position 3 Position 4. Product Type Duct Size Duct-To-Duct Spacing - Horizontal and Vertical Horizontal Duct Positions SP = Spacer 2W = 2" Width 15 = 1-1/2" 2 = Two 3W = 3" Width 20 = 2". 4W = 4" Width 30 = 3". 5W = 5" Width 6W = 6" Width Technical Information Horizontal Duct-To-Duct Spacing Center-To-Center Spacing Bottom of Bottom of Trench Duct Duct Duct Vertical Horizontal Trench to to Center of Bottom Overall Part Number Size OD Positions (Inches) (Inches) Vertical Horizontal Bottom of Duct Duct Length SP2W20-2 2" 2 2 2 SP2W30-2 2" 2 3 3 SP3W20-2 3" 2 2 2 SP3W30-2 3" 2 3 3 SP4W15-2 4" 2 SP4W20-2 4" 2 2 2 SP4W30-2 4" 2 3 3 SP5W20-2 5" 2 2 2 SP5W30-2 5" 2 3 3 SP6W20-2 6" 2 2 2 SP6W30-2 6" 2 3 3 I. Lamson & Sessions Ltd. 121 Watline Avenue Mississauga, Ontario Canada L4Z 1P2. (. F.. 7F78 SP 10/06.)
4 Lamson & Sessions 2006. Gross Automation (877) 268-3700 Snap-Loc Spacers NEW. Carlon Snap-Loc Spacers . 8" Spa ! cers Carlon Snap-Loc duct Spacers provide stability, consistent separation and relieve direct stress for duct materials encased in concrete, and direct bury applications. Carlon Snap-Loc Spacers provide: A side dovetail rail and groove design allowing for side-by-side interchangeability of conduit spacer sizes while maintaining horizontal stability. Locking key ways incorporated into intermediate Spacers eliminate the need for costly top Spacers in each size. The locking key ways provide for the use of a beaded strap that secures the top section of conduit. Rebar Holder Snap-Loc Beaded Strap &. Reducer Locking Key Way 1" and 2" Snap-Loc Reducers allow fixturing of 1" or 2" conduit inside larger Spacers .
5 The Snap-Loc Rebar Holder provides stabilization on large banks of Spacers . Nonmetallic Snap-Loc Spacers are designed specifically for use with nonmetallic duct, with maximum dimensions as specified in NEMA TC-2, TC-6 & 8, TC-10 and ASTM F512. The innovative vertical and horizontal interlocking Snap-Loc design has tapered joining slots with maximum tolerances for easy job site assembly. IMPORTANT: 1. The use of duct Spacers for direct burial may result in excessive point deflections unless proper design engineering is applied, such as the proper compaction of the appropriate backfill material. 2. Carlon is NOT responsible for Snap-Loc Spacers used in direct bury design engineers and contractors are responsible for the design of the installation. w w w. c a r l o n . c o m 225. Gross Automation (877) 268-3700 Snap-Loc Spacers Dimensions Base Spacers Dimensions Intermediate Spacers Std.
6 Std. Part No. Size* A C D (Dia.) Ctn. Qty. Part No. Size* B C D (Dia.) Ctn. Qty. S288 JHN 2x11/2 100 S289 JHN 2x11/2 120. S288 JJN 2x2 100 S289 JJN 2x2 100. S288 JLN 2x3 100 S289 JLN 2x3 80. S288 LHN 3x11/2 90 S289 LHN 3x11/2 100. S288 LJN 3x2 80 S289 LJN 3x2 80. S288 LLN 3x3 60 S289 LLN 3x3 60. S288 NFN 4x1 70 S289 NFN 4x1 70. S288 NHN 4x11/2 50 S289 NHN 4x11/2 60. S288 NJN 4x2 50 S289 NJN 4x2 60. S288 NLN 4x3 60 S289 NLN 4x3 50. S288 PHN 5x11/2 50 S289 PHN 5x11/2 50. S288 PJN 5x2 60 S289 PJN 5x2 50. S288 PLN 5x3 50 S289 PLN 5x3 30. S288 RHN 6x11/2 50 S289 RHN 6x11/2 50. S288 RJN 6x2 50 S289 RJN 6x2 40. S288 RLN 6x3 40 S289 RLN 6x3 30. S288 SHN 8x11/2 30 S289 SHN 8x11/2 30. S288 SJN 8x2 30 S289 SJN 8x2 30. *First number indicates trade size of duct, second number indicates separation between conduits or ducts.
7 Accessories Hole Dia. = .688 min..750 max. 15" in length Snap-Loc Reducer Rebar Holder Beaded Strap Std. Std. Std. Part No. Size Ctn. Qty. Part No. Ctn. Qty. Part No. Ctn. Qty. S287F 1" 100 S258RH 100 S28612 100. S287J 2" 100. Specifications C Suggested Specification (Duct) (Conduit) bank shall be encased in concrete with at least three inches of concrete at the top and bottom and two inches on each side. A horizontal and vertical separation between the ducts of ____* inches shall be maintained by installing Carlon high impact Spacers with horizontal and vertical locking intervals of B. ____** feet. *Standard Separations of 1", 11/2", 2", and 3" are available. A **Preferred interval between spacer assemblies is 8 to 10 feet. 3" Standard for all Base Spacers Installation note The Spacers and Rebar Holder are designed with a dovetail tongue and groove IMPORTANT: feature for easy installation.
8 1. The use of duct Spacers for direct burial may result If required to permanently fix the position of a group of Spacers and/or Rebar in excessive point deflections unless proper design Holder, the following are recommended procedures: engineering is applied, such as the proper com- 1. Use Carlon Quick-set Cement glue during assembly or spot glue after assembly paction of the appropriate backfill material. to secure. 2. Carlon is not responsible for Snap-Loc Spacers used 2. During assembly, deform the edge of the tongue or groove portion of the dove- in direct bury design engineers and tail slide with a pair of pliers or similar tool. This deformation will create an contractors are responsible for the design of the interference, restricting movement. installation. 3. An assembled system may be wired together for additional support.