1 specification SubmittalpageJob Name:Job Number:Model Numbers:Cas taR WirelessLoad Controls369987c 1 taR Wireless load ControlsThe Cas taR Wireless family of Dimmers and Switches can be controlled directly and remotely when paired with PicoR Remote Controls providing a system that delivers convenience and ease of taR Wireless Dimmers and Switches use LutronR patented Clear ConnectR RF Technology which enables Wireless communication with PicoR Remote Controls and the LutronR Smart Bridge and Smart Bridge Works with PicoR Remote control Works with the LutronR App (via a Smart Bridge or Smart Bridge PRO)
2 1 LutronR patented Clear ConnectR RF Technology works through walls and floors Includes Front Accessible Service Switch (FASST) for safe lamp replacement Works with LutronR Radio Powr SavrT Occupancy and Vacancy Sensors in standalone applications (sensors do not work with Smart Bridge or Smart Bridge PRO) Cas taR Wireless In-Wall SwitchesCas taR Wireless In-Wall DimmersCas taR Wireless Plug-In Lamp DimmerCas taR Wireless ELV+ Dimmer1 The Lutron App is required for setup and usage with the Smart Bridge and Smart Bridge PRO. The LutronR App is compatible with iOSR devices version or later and AndroidT devices or later.
3 IOS is a registered trademark of Cisco in the and other countries and is used under license. Android is a trademark of Google : Certain models or load types will require a neutral connection (see load Types and Capacity sections). specification SubmittalpageJob Name:Job Number:Model Numbers:Cas taR WirelessLoad Controls369987c 2 Approvals cULus Listed NOM Certified FCC Approved. Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules Industry Canada Certified IFTEL Certified NEMA 410 (-5 ANS, -6 ANS, -5WS, -10 NXD, -5NE)PowerOperating voltage: 120 V~ 50/60 Hz: -3 PCL, -6 WCL, -10 NXD, -6 ANS, -5 ANS, -5NE 120 / 277 V~ 50 / 60 Hz: -5WS-DVKey Design Features Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.
4 Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits. load Controls always operate locally and do not require system control . Power failure memory: should power be interrupted, the control will return to its previously set level prior to the interruption when power is restored. PD-5WS-DV, PD-5 ANS, PD-6 ANS, and PD-10 NXD use conventional 3-way wiring. Uses LutronR ClaroR Wallplates or designer-style wallplates from other manufacturers. Wallplates are sold separately. LutronR ClaroR Wallplates snap on with no visible means of attachment.
5 Requires a 1-gang wallbox. 31 2 in (89 mm) depth recommended, 21 4 in (57 mm) depth minimum. Green status LED(s) to indicate load Communications and Capacity Cas taR Wireless In-Wall Switches and Dimmers communicate with PicoR remote Controls and the LutronR Smart Bridge/Smart Bridge PRO through Radio Frequency (RF). The Cas taR Wireless In-Wall Switches and Dimmers communicate with LutronR Radio Powr SavrT Occupancy and Vacancy Sensors in a standalone application. Sensors do not work with Smart Bridge or Smart Bridge PRO. The Cas taR Wireless In-Wall Switches and Dimmers must be located within 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls, of PicoR remote Controls and LutronR Smart Bridge limits PicoR Remote Controls and Radio Powr SavrT Occupancy Sensors: up to 10 devices (total) may be paired to each Cas taR Wireless In-Wall Switch/Dimmer (with no Smart Bridge installed).
6 Smart Bridge or Smart Bridge PRO system: up to 50 total Wireless devices (Cas taR Wireless Dimmers/Switches, PicoR Remote Controls , and Shades) are supported per system. Smart Bridge or Smart Bridge PRO counts as one Ambient operating temperature: 32 F to 104 F (0 C to 40 C), 0% to 90% humidity, non-condensing. Indoor use only. PD-5WS-DV, PD-5 ANS, PD-6 ANS, and PD-10 NXD can be used with mechanical switch in 3-way applications. specification SubmittalpageJob Name:Job Number:Model Numbers:Cas taR WirelessLoad Controls369987c 3 Dimmer PD-10 NXDPlug-In Dimmer PD-3 PCLIn-Wall Dimmer PD-6 WCLELV+ Dimmer PD-5NE2-wire Switch PD-5WS-DVNeutral Switch PD-5 ANS, PD-6 ANSS imple two-wire installation (no neutral wire required) 1 Capable of dimming loads Favorite button (user defined one touch light level) Works with Hi-lumeR 1% 2-Wire LED Drivers (Forward-phase only) Works with Power Interfaces (PHPM and GRX-TVI) Works with Power Interfaces (PHPM-SW)
7 No wiring required 1 In some low-wattage applications the PD-10 NXD will require a neutral wire specification SubmittalpageJob Name:Job Number:Model Numbers:Cas taR WirelessLoad Controls369987c 4 Type and Capacity - SwitchesModel NumberDescriptionVoltageLoad TypeMinimum LoadMaximum load 3 Not GangedEnd of GangMiddle of GangPD-5WS-DV1 Two -w i re switch120 V~Incandescent / Halogen25 W600 W450 W350 W277 V~Incandescent / Halogen25 W1350 W110 0 W800 W120 V~MLV25 W600 VA /475 W450 VA / 350 W 350 VA / 275 W277 V~MLV25 W1350 VA /1075 W 1100 VA / 875 W 800 VA / 625 W120 V~General Purpose A3 A3 A3 A120 / 277 V~LEDUse LUT-MLC25 A4 A3 A120 / 277 V~FluorescentUse LUT-MLC25 A4 A3 A120 V~ELVUse LUT-MLC2600 W450 W350 W277 V~ELVUse LUT-MLC21350
8 W110 0 W800 WPD-5 ANSN eutral-wire switch (neutral connection required)120 V~Incandescent / Halogen10 W600 W600 W600 WMLV10 W600 VA600 VA600 VAFan0 .1 A3 A3 A3 ALED1 bulb5 A5 A5 AFluorescent1 ballast5 A5 A5 AELV10 W600 W600 W600 WPHPM-SW1 interface2 interfaces2 interfaces2 interfacesPD-6 ANSN eutral-wire switch (neutral connection required)120 V~Incandescent / Halogen10 W720 W720 W600 WMLV10 W720 VA720 VA600 VAFan0 .1 ALED1 bulb6 A6 A5 AFluorescent1 ballast6 A6 A5 AELV10 W720 W720 W600 WPHPM-SW1 interface3 interfaces3 interfaces3 interfaces1 No neutral wire To ensure proper operation of the switch with LED, fluorescent, and ELV loads, a LUT-MLC (included) may be required, especially at lower wattages.
9 If the status LED on the switch is flashing or solid red in color, a LUT-MLC must be installed. To guarantee best performance, installing a LUT-MLC with these load types regardless of wattage is recommended. Rarely, some load types may still flicker or glow in the off state even with the LUT-MLC installed, in which case a different load may be required or more than one LUT-MLC is See Ganging and Derating section. specification SubmittalpageJob Name:Job Number:Model Numbers:Cas taR WirelessLoad Controls369987c 5 Cannot be Need to change load type to MLV. See See bulb list at F or PD-10 NXD, a neutral connection is required for MLV loads, LED drivers, dimmable ballasts, and power modules (PHPM-PA, PHPM-3F, and GRX-TVI).
10 5 Compatible dimmable ballasts include Tu-WireR, Mark X, and These loads are best operated using a forward-phase control . Consult to ensure the appropriate phase for bulb models SSL7 compliant when in forward-phase. 8 Canadian packaged Available in WH Kit model number. Kit includes (1) PD-3 PCL-WH, and (1) PJ2-3 BRL-WH-L01R (3-button with raise/lower Pico Wireless control in White).11 Kit model number. Kit includes (1) L-BDG2-WH (Cas ta Wireless Smart Bridge with HomeKit technology), (1) PD-3 PCL-WH, (1) PJ2-3 BRL-WH-L01R (3-button with raise/lower Pico Wireless control in White) and (1) L-PED1-WH (Single tabletop pedestal in White).