Example: tourism industry

CC-Link IE Field I/O Block and IO-Link Master …

CC-Link IE 2016-05 Product UpdateBuilt-in switch for daisy chaining CC-Link IE Field modules. M12 X-coded connectors 1 GBPS network speed wCC-Link IE Field I/O Block and IO-Link MasterDistributed Modular Controls Architecture for Gigabit NetworksCC-Link IE is the newest Industrial Ethernet network geared for complete vertical integration from plant enterprise network to the production floor. CC-Link IE Field offers tremendous application potential in all industries with its unmatched gigabit network and deterministic performance. Balluff is the first to introduce CLPA conformance tested and approved CC-Link IE Field based distributed modular I/O to build a machine mount controls architecture. CC-Link IE Field combined with IO-Link , provides for a resilient network for a multitude of devices including discrete and analog I/O, smart sensors, RFID, Vision and more.

www.balluff.com CCink Product pdate Built-in switch for daisy chaining CC-Link IE Field modules. M12 X-coded connectors 1GBPS network speed w CC-Link IE Field I/O Block and IO-Link Master

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of CC-Link IE Field I/O Block and IO-Link Master …

1 CC-Link IE 2016-05 Product UpdateBuilt-in switch for daisy chaining CC-Link IE Field modules. M12 X-coded connectors 1 GBPS network speed wCC-Link IE Field I/O Block and IO-Link MasterDistributed Modular Controls Architecture for Gigabit NetworksCC-Link IE is the newest Industrial Ethernet network geared for complete vertical integration from plant enterprise network to the production floor. CC-Link IE Field offers tremendous application potential in all industries with its unmatched gigabit network and deterministic performance. Balluff is the first to introduce CLPA conformance tested and approved CC-Link IE Field based distributed modular I/O to build a machine mount controls architecture. CC-Link IE Field combined with IO-Link , provides for a resilient network for a multitude of devices including discrete and analog I/O, smart sensors, RFID, Vision and more.

2 With its IP67 protection rating, this network Block promotes truly distributed modular architecture for seamlessly connecting sensors, actuators or smart IO-Link devices with standard M12 sensor cables - further reducing complexity and cost for special devices and cables. When building high I/O density applications, Balluff CC-Link IE Field blocks with 8- IO-Link Master ports can host 240 I/O points per node without compromising on speed or performace. Order CodeMax. inputsMax. outputsIO-Link PortsDescriptionBNI009416-16 PNP input only CC-Link IE Field blockBNI008T16-16 NPN input only CC-Link IE Field blockBNI00951616-16 PNP Configurable I/OCC-Link IE Field blockBNI008C161688-port IO-Link Master with 16 PNP configurableTechnical Information Network connectionCC-Link IE Field , M12 X-codedSensor/ IO-Link connectionM12 A-CodedPower connection7/8" 5-polePower DC 9A maxMax.

3 Input current per output current per channel2 AMax. output current per module9 AProtection per IEC 60529IP67 Operating Temp. range-5 C to 70 COrder CodeLengthRJ45-RJ45 CAT7 4-twisted pairBCC0 HZC1mBCC0 HZE2mBCC0 HZF5mBCC0 HZH10mM12 X-coded - RJ45 CAT7 4-twisted pair BCC0 HZJ1mBCC0 HZK2mBCC0 HZL5mBCC0 HZM10mM12 X-coded - M12 X-coded CAT7 4-twisted pairBCC0 HZN1mBCC0 HZP2mBCC0 HZR5mBCC0 HZT10m8-dual channel ports:n 16 input only n 16 configurable I/On 8 IO-Link or 16 configurable I/OLarge port LEDs indicating status or die-cast zinc with IP67 protection mounting for quick installation7/8" power connection with ability to diagnostic LEDsn Network & power statusn Module status (short circuit, over current)Large port LEDsn Connection status, active input/outputn port diagnostics (short circuit, over-current)Port labels on side, so they are visible even when port is in us