Example: confidence

Characteristics PM5560 powermeter w 1mod2eth - …

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applicationsDec 28, 20171 Product data sheetCharacteristicsMETSEPM5560PM5560 powermeter w 1mod2eth - upto 63th H -1,1M 4DI/2DO 52alarms - flush mountMainRangePowerLogicProduct namePowerLogic PM5000 Device short namePM5560 Product or component typePower meterComplementaryPower quality analysisUp to the 63rd harmonicDevice applicationPower monitoringWAGES meteringGatewayMulti-tariffType of measurementEnergyActive and reactive powerVoltageCurrentFrequencyPower factor[Us] rated supply V V AC ( Hz)Network frequency60 Hz50 Hz[In] rated current1 A5 APoles description3P + N3P1P + NPower consumption in VA10 VA at 480 VDisplay typeBacklit LCDD isplay resolution128 x 128 pixelsSampling rate128 samples/cycleMeasurement mA2 Analogue input typeCurrent (impedance mOhm)Voltage (impedance 5 MOhm)Measurement V AC Hz between phase and V AC Hz between phasesFrequency measurement HzNumber of inputs4 digitalMeasurement accuracy+/- % apparent power+/- % frequency+/- % active energy+/- 1 % reactive energy+/- % active power+/- % voltage+/- % power factor+/- C currentAccuracy classClass (active energy according to IEC 62053-22)Number of outputs2 digitalInformation displayedTariff 8 Communication

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Characteristics PM5560 powermeter w 1mod2eth - …

1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applicationsDec 28, 20171 Product data sheetCharacteristicsMETSEPM5560PM5560 powermeter w 1mod2eth - upto 63th H -1,1M 4DI/2DO 52alarms - flush mountMainRangePowerLogicProduct namePowerLogic PM5000 Device short namePM5560 Product or component typePower meterComplementaryPower quality analysisUp to the 63rd harmonicDevice applicationPower monitoringWAGES meteringGatewayMulti-tariffType of measurementEnergyActive and reactive powerVoltageCurrentFrequencyPower factor[Us] rated supply V V AC ( Hz)Network frequency60 Hz50 Hz[In] rated current1 A5 APoles description3P + N3P1P + NPower consumption in VA10 VA at 480 VDisplay typeBacklit LCDD isplay resolution128 x 128 pixelsSampling rate128 samples/cycleMeasurement mA2 Analogue input typeCurrent (impedance mOhm)Voltage (impedance 5 MOhm)Measurement V AC Hz between phase and V AC Hz between phasesFrequency measurement HzNumber of inputs4 digitalMeasurement accuracy+/- % apparent power+/- % frequency+/- % active energy+/- 1 % reactive energy+/- % active power+/- % voltage+/- % power factor+/- C currentAccuracy classClass (active energy according to IEC 62053-22)Number of outputs2 digitalInformation displayedTariff 8 Communication port protocolModbus RTU and ASCII 2 wires, : , and kbauds, even/odd or none, insulation: 2500 VJBUSM odbus TCP/IP : 10/100 Mbit/s, insulation.

2 2500 VEthernet Modbus TCP/IP daisy chainBACnet IPCommunication port supportRS485 EthernetCommunication gatewayEthernet/SerialData recordingAlarm logsData logsTime stampingMin/Max of instantaneous valuesEvent logsMaintenance logsMemory MBWeb servicesWeb serverAlarm notification by e-mailDiagnostic via predefined web pagesReal time viewing of dataEthernet serviceSNTP clientSNMP-TrapsMounting modeFlush-mountedMounting supportFrameworkStandardsEN 50470-3 IEC 62053-22 IEC 60529EN 50470-1UL 61010-1 IEC 61557-12 IEC 62053-24 Product certificationsCE conforming to IEC 61010-1 CULus conforming to UL 61010-1 BTLW idth96 mmDepth72 mmHeight96 mmProduct weight450 gEnvironmentElectromagnetic compatibility conducted and radiated emissions class class B, conforming to EN 55022 limitation of voltage changes, voltage fluctuations and flicker in low-voltage, conforming to IEC61000-3-3 limits for harmonic current emissions class class A, conforming to IEC 61000-3-2 conducted RF disturbances class level 3, conforming to IEC 61000-4-6 magnetic field at power frequency class level 4, conforming to IEC 61000-4-8 electrostatic discharge class level 4 (8 kV ), conforming to IEC 61000-4-2 radiated radio-frequency electromagnetic field immunity test, conforming to IEC 61000-4-33 electrical fast transient/burst immunity test class level 4, conforming to IEC 61000-4-4 surge immunity test class level 4, conforming to IEC 61000-4-5 voltage dips and interruptions immunity test, conforming to IEC 61000-4-11IP degree of protectionIP52 (front) conforming to IEC 60529IP30 (body)

3 Conforming to IEC 60529 Relative % 50 CPollution degree2 Ambient air temperature for CAmbient air temperature for COperating altitude3000 mOffer SustainabilitySustainable offer statusGreen Premium productRoHS (date code: YYWW)Compliant - since 1340 - Schneider Electric declaration of conformitySchneider Electric declaration of conformityREAChReference not containing SVHC above the thresholdReference not containing SVHC above the thresholdProduct environmental profileAvailableProduct environmentalProduct end of life instructionsAvailableEnd of life manual


Related search queries