Example: air traffic controller

Circuit Guard - Hubbell Wiring Device

Circuit Guard Ground Fault ProductsHubbell s 30 Amp GFCI Portable or Hard-Wired Manual or Automatic Reset Optional Use Audible Alarm UL Enclosure Type 4X 120, 240 and 120/240 Volt Models Remote Signaling Capability Class A GFCI ProtectionHard-Wired Product Offering Features and Benefits30 AMP RatingAll products feature a 30 Amp maximum rating,but may be used in any15 or 20 Amp PhaseApplicationsThese single-phase prod-ucts are available in120V, 240V, or 120 /240V4-wire Reset orAutomatic ResetVersions All units may be ordered ineither a Manual Reset orAutomatic Reset version. The manual reset productfeatures a black coverlabel, and the automaticreset product features ayellow cover label. Audible Alarm All voltage types are available with an audible alarm. The alarm alerts you if a ground fault hasoccurred and the GFCI has tripped. The alarm may be disabled or wiredinto a switch so that thecustomer has the choice of use or non-use.

Visit Hubbell Electronic Catalog for dimensions, materials, and technical data at www.hubbell-wiring.com Circuit Guard® 15 & 20 …

Tags:

  Circuit, Guard, Wiring, Circuit guard, Hubbell, Hubbell wiring

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Circuit Guard - Hubbell Wiring Device

1 Circuit Guard Ground Fault ProductsHubbell s 30 Amp GFCI Portable or Hard-Wired Manual or Automatic Reset Optional Use Audible Alarm UL Enclosure Type 4X 120, 240 and 120/240 Volt Models Remote Signaling Capability Class A GFCI ProtectionHard-Wired Product Offering Features and Benefits30 AMP RatingAll products feature a 30 Amp maximum rating,but may be used in any15 or 20 Amp PhaseApplicationsThese single-phase prod-ucts are available in120V, 240V, or 120 /240V4-wire Reset orAutomatic ResetVersions All units may be ordered ineither a Manual Reset orAutomatic Reset version. The manual reset productfeatures a black coverlabel, and the automaticreset product features ayellow cover label. Audible Alarm All voltage types are available with an audible alarm. The alarm alerts you if a ground fault hasoccurred and the GFCI has tripped. The alarm may be disabled or wiredinto a switch so that thecustomer has the choice of use or non-use.

2 Remote Output Signal Remote monitoring is also available. The units may be ordered with a line voltage output or eithera 12V DC or 24V DC output signal. These signals can be used to turn on a remote buzzer, light,or signal a PLC in the event of a ground fault Neutral Protection All Hubbell Hard-Wired GFCI products come standard with open neutral protection and meetOSHA requirements for job-site use (confined space).Class A GFCI ProtectionOffers a 4 to 6 mA trip IndicatorsGreen light illuminates when unit has power and no ground fault is present. Red light begins blinking when a ground fault is detected and the output power is interrupted. Enclosure RatingAll products feature a UL Enclosure Type 4X FlexibilityEach unit comes standard with a foam gasket, mounting template, and detailed instructions forinstallation in a panel mount application. All Hard-Wired units may be either surface mounted orpanel Hub All hard-wired products come with a threaded hub that may be used with PolyTuff liquidtightconduit, flexible conduit, EMT, or rigid Reset GFCIR equires the GFCI to be manuallyreset for use by pressing thereset button after the loss of primary power.

3 Must be alsomanually reset after a groundfault condition. Manual reset is ideal for applications whereoperator injury might occur ifequipment were to restart after apower Reset GFCIA utomatically energizes or setsthe GFCI for use once power isapplied to the Circuit . After aground fault condition the unitmust be reset by pushing thereset button. This feature elimi-nates the need for the unit to bereset each time the power isturned on. Automatic reset isideal where temporary power failure is likely and undesirablesuch as waste-water treatmentplants, portable signs and somepump Number Configurator: Example: Catalog Number: GFHW23015 VoltageAmperageReset TypeOutput SignalMounting StyleGround Hard-1 - 120 Volt3- 30 Amp0- Manual 0 - none5- Panel Mount/Faultwired2- 240 Volt1 - Automatic 1- Audible AlarmSurface Mount3 - 120/240 2 - Line VoltageVolt 4 Wire3 - 24 Volt DC4 - 12 Volt DCOther Examples: GFHW13015:Ground Fault, Hard-Wired, 120V, 30 Amp, Manual Reset, Audible Alarm, Panel MountGFHW23145:Ground Fault, Hard-Wired, 240V, 30 Amp, Automatic Reset.

4 12 VDC Output Signal,Panel Hubbell Electronic Catalog for dimensions, materials,GFHW23015 Portable Product Offering Features and Benefits30 Amp RatingPortables feature a 30 Amprating, but may be wiredwith 15, 20 or 30 Ampplugs and Phase ApplicationsAll units are available ineither 120 or 240 volt or AutomaticReset VersionsAll units may be ordered ineither a Manual Reset orAutomatic Reset version. The manual reset productfeatures a black cover labeland the automatic resetproduct features a yellowcover label. Open Neutral ProtectionAll Hubbell portable GFCI products feature open neutral relay A GFCI ProtectionOffers a 4 to 6 mA trip IndicatorsGreen light illuminates when unit has power and no ground fault is present. Red light begins blinking when a ground fault is detected and the output power is interrupted. Enclosure RatingAll products feature a UL Enclosure Type 4X Amp Portables Come with Stripped Wire Leads on Both EndsPigtails are provided so that each end user may install the type of plug and connector they wish to may be wired with any 15, 20, or 30 Amp, 120 or 240 Volt, single -phase plug and Cord on All 30 Amp PortablesPortables up to fifty feet long feature 10/3 AWG SJEOOW cord.

5 One hundred foot model features 8/3 AWG wire leads makethe connection choice all yours!Whether you need HubbellPin and Sleeve, WatertightSafety Shroud Twist-Lock ,Hubbellock , ERGO Grip,or any other 15A, 20A, or30A 120 or 240 Volt single-phase plug and connector,installation is easy withstripped wire leads thatcome on each of the 30 Amp portable GFCI's. Catalog Number Configurator: Example: Catalog Number: GFP2311 GFP2311 VoltageAmperageReset TypeCord LengthGround Portable1 - 120 Volt3- 30 Amp0 - Manual 1- 2 FeetFault2- 240 Volt1- Automatic 2 - 25 Feet3 - 50 Feet4 - 100 Feet5 - 6 FeetOther Examples: GFP2304:Ground Fault, Portable, 240V, 30 Amp, Manual Reset, 100 Foot CordGFP1313:Ground Fault, Portable, 120V, 30 Amp, Automatic Reset, 50 Foot CordPlug and Connector Selector Chart (Partial Listing)The chart below is a list of some of the possible Hubbell plug and connector products that can beused with the Hubbell Portable GFCI's.

6 Please visit the electronic catalog @ for a complete listing of 15, 20 and 30 Amp products that can be usedwith these GFCI Part NumbersAmpVoltageStyleInsulgrip HBL5266C & HBL5269C15120 Straight BladeErgo GripHBL5567EY & HBL5579EY20240 Straight BladeInsulgripHBL2621 & HBL262330240 Twist-LockWatertight Safety-ShroudHBL2621SW & HBL2623SW30240 Watertight Twist-LockIEC Pin & SleeveHBL330P6W & HBL330C6W30240 Watertight Pin & SleeveInsulgrip Pin & SleeveHB330PS2W & HBL330CS2W30240 Insulgrip Pin & SleeveHubbellock HBL23035B & HBL23032B20 125 Hubbellockand technical data at Visit Hubbell Electronic Catalog for dimensions, materials, and technical data at Circuit Guard 15 & 20 Amp Portable GFCI Line Cords Straight Blade Catalog NumberVoltageAmperageCord LengthReset TypeGFP4C15A120V AC15A18"Automatic ResetGFP4C15M120V AC15A18"Manual ResetGFP6C15A120V AC15A6'Automatic ResetGFP6C15M120V AC15A6'Manual ResetGFP25C15A120V AC15A25'Automatic ResetGFP25C15M120V AC15A25'Manual ResetGFP3C20M120V AC20A3'Manual Reset15 Amp Portable GFCI Line Cords w/ Elastogrip Watertight Straight BladeGFP50C15WM120V AC15A50'Manual Reset GFP100C15WM120V AC15A100'Manual Reset15 Amp GFCI Line Cord OEM VersionGFPOEMM120V AC15A15'Manual Reset15 & 20 Amp Portable GFCI Line Cord Twist-Lock GFP3C15 MTL120V AC15A3'Manual ResetGFP3C20 MTL120V AC20A3'Manual Reset15 Amp Portable Plug-In.

7 And GFCI TesterCatalog NumberVoltageColorDescriptionReset TypeGFP5266CY120V ACYellowWired onManual ResetGFP5266C120V ACBlackWired on Manual ResetGFP1C120V ACYellow1' Line CordManual Reset GFP315A120V ACWhite3 outlet plug-inManual ResetGFT2G120V ACWhiteGFI TesterN/A15 & 20 Amp Multi-Outlet Portable and GFCI ModuleGFP15M15A 125 VYellow4 Outlet, 6' CordManual ResetGFP20M20A 125 VYellow4 Outlet, 6' CordManual ResetGFM2020A 125 VYellowNEMA 3R ModuleManual ResetIndustrial Portable GFCIThe Hubbell Industrial Portablecomes with two HubbellHBL5252 or HBL5352heavy-duty GFM20 module features the same openneutral protection as allHubbell Portable GFCI's. TheGFP15M & GFP20M are fully field-repairable. GFCI Tester Designed to measure the trip level of portable or wired-in GFCI's in a range from 2-7 mA. Leakage level can be adjusted from 2-7 mA. Will measure leakage level in small portable tools and appliances from 1-7 mA.

8 Ideal for measuring the leakage level of GFCI breakers, GFCI portables and GFCI InformationFeatures and BenefitsNEWGFP4C15 AGFP3C20 MTLGFP5266 CYGFM20 GFT2 GGFP15 MPrinted In Specifications subject to change without notice. Registered trademark of Hubbell Incorporated H5004 Worldwide LocationsHubbell Canada (905) 839-1138, Fax (905) 839-9108 Hubbell Ltd. England (441) 234-855444, Fax (441) 234-854008 Hubbell -Taian Co., Ltd., (886) 2 567-5995, Fax (886) 2 567-4853 Hubbell de Mexico, de (52) 5 575-2022, Fax (52) 5 559-8626 Caribe Sales Agencies, Puerto Rico (809) 720-7185, Fax (809) 789-2796 NEW


Related search queries