Example: biology

Commercial Packaged Rooftop Units Standard- …

LANDMARK . Performance Marked by Flexibility . Commercial Packaged Rooftop Units Standard- and High-Efficiency 2- to 25-Ton KG/KC/KH/KHB and KH/D**B/M Models UP TO SEER, IEER. AND EER. Performance Marked by Flexibility . When it comes to reliable and efficient performance, Landmark Rooftop Units have always been a standout for light Commercial applications. Now we've built more flexibility into the line, making Landmark an excellent choice for virtually any application. Configuration choices for greater energy-savings potential LANDMARK Rooftop The advantages of Landmark Rooftop Units lie Units AT A GLANCE: not only in flexibility and simplicity, but also in efficiency. Landmark Units are available in Engineered for installation standard- and high-efficiency models, and with flexibility, energy-efficient performance and easy serviceability the addition of the optional MSAV supply fan, are up to 27% more efficient.

Commercial Packaged Rooftop Units Standard- and High-Efficiency 2- to 25-Ton KG/KC/KH/KHB and KH/D**B/M Models UP TO 16.5 SEER, 14.8 IEER AND 13.0 EER

Tags:

  Standards, Commercial, Unit, Packaged, Rooftop, Commercial packaged rooftop units standard

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Commercial Packaged Rooftop Units Standard- …

1 LANDMARK . Performance Marked by Flexibility . Commercial Packaged Rooftop Units Standard- and High-Efficiency 2- to 25-Ton KG/KC/KH/KHB and KH/D**B/M Models UP TO SEER, IEER. AND EER. Performance Marked by Flexibility . When it comes to reliable and efficient performance, Landmark Rooftop Units have always been a standout for light Commercial applications. Now we've built more flexibility into the line, making Landmark an excellent choice for virtually any application. Configuration choices for greater energy-savings potential LANDMARK Rooftop The advantages of Landmark Rooftop Units lie Units AT A GLANCE: not only in flexibility and simplicity, but also in efficiency. Landmark Units are available in Engineered for installation standard- and high-efficiency models, and with flexibility, energy-efficient performance and easy serviceability the addition of the optional MSAV supply fan, are up to 27% more efficient.

2 * For additional 2- to 25-ton gas/electric and savings, high-efficiency models qualify for many electric/electric Units ; state and local utility rebates. 2- to 20-ton heat pump Units Standard- and high-efficiency Over 30 features designed to reduce Units available installation and service time Building automation integration More than 100 field-selectable Landmark Rooftop Units have been designed improves efficiency and comfort options to ensure fast and so that installation and service time are easy installation reduced. An isolated compressor compartment All Landmark Units can now be integrated means easier, more accurate charge with the industry's leading building automation Optional MSAV supply fan confirmation. The slide-out blower makes system protocol using the BACnet option.

3 Technology with variable-frequency cleaning the blower wheel and belt tensioning, BACnet allows remote monitoring and drive that delivers fan power savings of up to 61% adjustment or replacement quicker and easier. adjusting of the building's heating, cooling And the accessible gas compartment allows and humidity levels, as well as control of the Available through select Lennox easy access to all gas components, making rest of the building's systems, like signs, PartsPlus stores and Lennox analysis and service quicker. lighting, refrigeration and more. Commercial warehouses Readily available for your specific light EFFICIENCY RATING Commercial application Up to SEER, IEER Every Lennox Commercial distribution and EER facility has Landmark Units ready for WARRANTIES immediate shipment, thanks to daily restocking.

4 In many major markets, Units 15-Year Limited Warranty can be picked up the same day they're on stainless steel gas heat exchanger ordered, and Units are available within 10-Year Limited Warranty 48 hours or less to 98% of North America. on aluminized gas heat exchanger 5-Year Limited Warranty on compressor 3-Year Limited Warranty on Environ coil system Call 1-877-792-0024 to get quotes within minutes, 1-Year Limited Warranty and to check availability in your area. on covered components See warranty certificate for actual details. *Part load, IEER improvement. Comparing standard IEER system to optional MSAV IEER system. Field-installed options allow extensive customization Landmark is ready to conform to your application The Landmark line gives you the flexibility to choose from electric-electric and dual-fuel heat pump configurations in just the right size and at exactly the right price.

5 Standard- efficiency Units are available in 2 to 25 tons, and high-efficiency models have capacities ranging from 2 to 10 tons. More than 100 field-installed options allow installers to quickly configure Units to perfectly fit the application. Field-installed accessories for fast LPG Conversion Kit (Gas/Electric only) Factory options or replacement -40 F cold weather kit (Gas/Electric only). field accessories Landmark Units include convenient features For maximum time and cost flexibility, Combustion air intake and flue exhaust like plug connections for wiring, panel choose to have these options installed extensions (Gas/Electric only). knock-outs and pre-installed accessory in the field or at the factory. framing. You can choose a stock unit and Blower proving switch Economizers quickly install accessories for those Dirty filter switch fast-track replacement jobs.

6 Barometric relief dampers Manual outdoor air dampers (25%). Field-powered GFI High- and low-static drive kits Motorized outdoor air dampers Disconnects Heaters (electric/electric only). Economizers with single or dual BACnet module enthalpy control Factory-installed options Novar 2051 ETM module for fast installation Electric heat For quick, built-to-order solutions, 50% constant-volume power exhaust fan Landmark Units can be built and tested CO2 sensor at the factory to exact specifications in just weeks, with these options: Return and supply air smoke detectors MSAV (Multi-Stage Air Volume) supply Low ambient kits fan option Hail guards Coil corrosion protection Link to the L Connection Network line of Stainless steel heat exchanger Commercial controls with an optional Network Thermostat Controller Hinged doors LANDMARK 4 8.

7 5. 1. Environ Coil System: Uses up to 52% less refrigerant, is 1 9 3. up to 59% lighter and has up to 20% fewer brazed joints 2. than typical Units . 6. 11. 7. 2 Scroll Compressor: Standard on all Units for reliable 10. long-term operation. High-Pressure Switch: Improves reliability by safeguarding 3 . compressor from extreme operating conditions. 8 Independent Motor Mount: Allows for easy and efficient Slide-Out Blower: Reduces time needed to adjust fan 4 service access without removing the top panel. speed, belt tensioning or blower cleaning. 9 Isolated Compressor Compartment: Allows performance 5 Predefined Supply Fan Motor/Drive Combinations: check during normal compressor operation without Make selecting components to meet static and airflow disrupting airflow.

8 Requirements quick and easy. Fork Slots on Three Sides: Easy to pick up and transport . Easy-Access Gas Compartment: Allows access to all 6 Units from almost any angle. gas components. Full-Perimeter Base Rail (with Rigging Holes): Provides . 7 Corrosion-Resistant, Removable Drain Pan: Provides greater structural integrity, so the unit is easier to handle application flexibility, durability and improved when rigging and transporting. serviceability. Bottom drain capability also standard. Landmark high-efficiency Rooftop unit performance specifications COOLING DATA HEATING INPUT PHYSICAL DATA. NOM. DIMENSIONS SHIP WT. TON MODEL EER IEER LOW STD. MED. HIGH H X W X L [INCHES] [LBS.]. KGB072H4B /. 6 65 108 150 47 x 47 x 86 690. KGB074H4T. KGA092H4B/M 130 180 240 47 x 61 x 102 1,185.

9 KGA102H4B/M 130 180 240 47 x 61 x 102 1,192. GAS/ 10 KGA120H4B/M 130 180 240 47 x 61 x 102 1,227. ELECTRIC 13 KGA156H4B/M 260 360 55 x 92 x 108 2,135. Units 15 KGA180H4B/M 260 360 480 55 x 92 x 133 2,315. KGA210H4B/M 260 360 480 55 x 92 x 133 2,440. 20 KGA240H4B/M 260 360 480 55 x 92 x 133 2,525. KW RANGE. KCB072H4B /. 6 47 x 47 x 86 661. KCB074H4T. KCA092H4B/M 47 x 61 x 102 1,137. KCA102H4B/M 47 x 61 x 102 1,144. ELECTRIC/ 10 KCA120H4B/M 47 x 61 x 102 1,179. ELECTRIC 13 KCA156H4B/M 55 x 92 x 108 1,985. Units 15 KCA180H4B/M 55 x 92 x 133 2,165. KCA210H4B/M 55 x 92 x 133 2,290. 20 KCA240H4B/M 55 x 92 x 133 2,375. 47 CAP. HSPF/COP 47 17 CAP. COP 17. 2 KHB024H4D 24,000 13,000 39 x 47 x 86 608. 3 KHB036H4D 35,600 19,200 39 x 47 x 86 608. 4 KHB048H4D 46,000 26,000 47 x 47 x 86 681.

10 HEAT 5 KHB060H4D 59,000 34,000 47 x 47 x 86 787. PUMPS KH/DB092H4B/M 86,000 51,000 47 x 61 x 102 1,158. 58,000/. KH/DB102H4B/M 100,000 47 x 61 x 102 1,160. 56,000. 10 KH/DB122H4M 116,000 70,000 47 x 61 x 125 1,301. Landmark Standard- efficiency Rooftop unit performance specifications COOLING DATA HEATING INPUT PHYSICAL DATA. NOM SEER OR DIMENSIONS SHIP WT. TON. MODEL EER IEER LOW STD. MED. HIGH H X W X L [INCHES] [LBS.]. 2 KGB024S4D 65 39 x 47 x 86 571. KGB030S4D 65 39 x 47 x 86 574. 3 KGB036S4B/D 65 108 39 x 47 x 86 596. 4 KGB048S4B/D 65 108 150 39 x 47 x 86 596. 5 KGB060S4B/D 65 108 150 47 x 47 x 86 690. 6 KGB074S4B/T 65 108 150 47 x 47 x 86 690. GAS/ELECTRIC Units . KGB090S4B/T 108 150 47 x 47 x 99 843. KGB092S4B 130 180 240 47 x 61 x 102 1,003. KGA092S4M 130 180 240 47 x 61 x 102 1,003.