Example: stock market

CONCRETE MANHOLES

MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE PIPESECTION 3 SHAW PIPE produces circular, precast , concretemanholes in diameters 1050mm through 3000mm . precast , CONCRETE MANHOLES are most frequently usedfor pipeline and sewer entry and are easy to installand low in PIPE follows various standards andspecifications in the production of precast , concretemanhole units. These standards and specificationsare listed in the "Specifications" precast , CONCRETE manhole configurationsconsist of a precast base or tee base, intermediaterings, flat top cover or eccentric cone top section,grade rings and cast iron frame and cover. Largediameter MANHOLES or rectangular MANHOLES can beprecast upon PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION INFOOnce this information has been received, astandard shop drawing form is filled out for eachmanhole in the , the total height of the manhole (laid height)is determined, by calculating the difference inelevation between the top of CONCRETE cover andthe lowest pipe invert (or bottom of sump).

SHAW PIPE produces circular, precast, concrete manholes in diameters 1050mmØ through 3000mmØ. Precast, concrete manholes are most frequently used for pipeline and sewer entry and are easy to install and low in cost. SHAW PIPE follows various standards and specifications in the production of precast, concrete manhole units.

Tags:

  Precast, Manholes

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CONCRETE MANHOLES

1 MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE PIPESECTION 3 SHAW PIPE produces circular, precast , concretemanholes in diameters 1050mm through 3000mm . precast , CONCRETE MANHOLES are most frequently usedfor pipeline and sewer entry and are easy to installand low in PIPE follows various standards andspecifications in the production of precast , concretemanhole units. These standards and specificationsare listed in the "Specifications" precast , CONCRETE manhole configurationsconsist of a precast base or tee base, intermediaterings, flat top cover or eccentric cone top section,grade rings and cast iron frame and cover. Largediameter MANHOLES or rectangular MANHOLES can beprecast upon PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION INFOOnce this information has been received, astandard shop drawing form is filled out for eachmanhole in the , the total height of the manhole (laid height)is determined, by calculating the difference inelevation between the top of CONCRETE cover andthe lowest pipe invert (or bottom of sump).

2 Thetop of CONCRETE cover elevation is typically set as300mm below finished grade, to provide anallowance for final grade adjustment once themanhole has been , the pipe angles, size and type are determinedand laid out. Angles and pipe inverts are checkedto ensure sufficient clearance between adjacentpipes. All angles are measured clockwise fromthe outlet opening which is taken to be 0 a manhole with two or more inlet pipes, theangle for each pipe relative to the outlet , the distance to the center of each pipeopening is determined ( + to CL). All distances aremeasured from the outside bottom of the manholesection in which the opening is located. Typicallyall openings are in the base section, unless thereis a large change in elevation between pipes.

3 Ifthis is the case, the height of the base section,and intermediate sections will be adjusted toensure that there is sufficient clearance betweenthe opening and the manhole , the manhole sections are selected andlisted, giving the laid height of each piece andany special requirements for each types are listed for each pipe, and anyspecial instructions are otherwise specified, shop drawings aresent to the contractor for review and approval bythe project engineer. Any revisions required bythe engineer or contractor are made, then thefinal approved shop drawings are issued to ourproduction staff for manufacture a manhole for a specific project,certain information is required to develop shopdrawings which are used by our production andshipping staff to manufacture and deliver theappropriate pieces which make up the which is necessary to develop a shopdrawing normally comes from a set of engineeringdrawings containing a plan and profile of the sewerline.

4 The minimum amount of information todetermine required manhole layout: Finished Grade Elevation (or top of concretecover if manhole extends above grade) Size and type of pipe entering the manhole(nominal diameter and pipe material) All pipe inverts (elevation at inside bottom of thepipe taken at the manhole wall) Angles between piping (measured clockwisefrom the outlet pipe which is taken as 0 ) Size of manhole (nominal inside diameter)Additional information which should beprovided would include: Sump depth (if required) Base configuration (with or without benching, withor without bottom slab) Opening type (water tight rubber gasket, smoothor rough cut hole, doghouse opening.) Gasket type for joints / confined rubber o-ring, Ram-Nek butyl rubber strip, no gasket Special allowances for grade adjustment Type of access hatch or cover to be used (cast ironframe and cover, aluminum access hatch, etc.)

5 Size and location of access opening inconcrete cover Special items to be cast into manhole sections(lifting davits, access frames, tie downs)How to Read SHAW PIPEM anhole Shop Drawings1 REF-24/25-12/06 Structure:Job Number:Job Name:Job Location:Specification:Contractor:MANHOL E DRAWINGJOB NAMEJOB LOCATION1050mm diameterCONTRACTOR NAMEP roduced By:Checked By:Frame/Ring:IMP R10 FRAMEG rate/Cover:IMP R10 COVERC hannel:3-Way Half Height BenchNotes:Elevation (View A-A)Opening SchedulePlan ViewBOM For StackBased on:Design Build HeightStack Build HeightFrame+ + Slab+ + Gain+ Height= Thickness+ Height= of Casting+ Height= SizePipe SizeCenterID0mm0 A-Lok535451mm300mm RCP B376mm#11,017mm90 A-Lok535451mm300mm RCP B426mm#22,034mm180 A-Lok535451mm300mm RCP B426mm#3 Section 1501103 BAGC 1751451 CAI 125011,269 DAI 125011,269 EAPB 950 BN11,757 Totals (pieces, kgs)54, 5, 2006 Submittal1 Shaw Highway # Box 2130 Lantz, NSB0N 1R0 Phone: (902) 883-2201 Fax.

6 (902) PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION INFO3 MANHOLE DIAMETER SELECTION GUIDE1200mm DIAMETER MANHOLES1050mm DIAMETER MANHOLESREF-26-12/06525mm 125 525mm Alok #850 Alok #850110 450mm 450mm Alok #740 Alok #74090 375mm 375mm Alok #640 Alok #640115 600mm 600mm Alok #970 Alok #970450mm 450mm 90 Alok #740 Alok #740525mm 525mm 110 Alok #850 Alok #850 GENERAL INFOSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION DIAMETER SELECTION GUIDE1500mm DIAMETER MANHOLES1800mm DIAMETER MANHOLES2100mm DIAMETER MANHOLESREF-28-03/094900mm 135 Alok #1470900mm Alok #1470110 750mm 750mm Alok #1200 Alok #120090 600mm 600mm Alok #970 Alok #97090 750mm 750mm Alok #1200 Alok #1200110

7 900mm 900mm Alok #1470 Alok #14701050mm 1050mm 115 Alok #1640 Alok #164090 900mm 900mm Alok #1470 Alok #1470110 1050mm 1050mm Alok #1640 Alok #16401200mm 1200mm Alok #1860 Alok #1860115 MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION INFO5 MANHOLE DIAMETER SELECTION GUIDEREF-28-03/092400mm DIAMETER MANHOLES3000mm DIAMETER MANHOLES110 1370mm 1370mm Alok #2040 Alok #20401500mm Alok #2300135 Alok #23001500mm Alok #23001500mm 115 1500mm Alok #2300 Alok #18601200mm 90 Alok #18601200mm 110 1370mm 1370mm Alok #2040 Alok #2040110 1200mm 1200mm Alok #1860 Alok #1860 Alok #16401050mm 90 Alok #16401050mm GENERAL INFOSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION GASKET CONNECTIONSTANDARD HOLE w/GROUTEDCONNECTIONDOGHOUSE OPENINGw/ GROUTED CONNECTIONSTANDARD PIPE CONNECTIONSG routNon-Shrink+ to CLPipe + 50mm Min.

8 + to CL+ to CLCast-in-PlaceBase SlabPipe + 50mm pipeNon Shrink Grout150mm PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION INFOT ypical Mono BaseREF-37-12/06 Wall, bottom, and benching cast as a single Bases are designed to provide cost efficienciesin standard sanitary sewer applications. Wherepossible, designers should specify mono bases. Inside Diameter:1067mm Wall Thickness:114mm Drop across Manhole:38mmAvailable with in-wall A-LOK gasket connection for the following nominal pipe sizes: 200mm PVC SDR 35 250mm PVC SDR 35 Base Section: APB 500 MonoLaid Height (mm): 500 Weight (kg): 137071067mm 500 MonoGENERAL INFOSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION 1050-3000mm DIAMETER MANHOLE BASE DETAILSREF-38-12/06 Inlets Available in 5 IncrementsRefer to _____ forPipe Size and Angle SelectionTSS Gasket JointInlet Invert ElevationAs SpecifiedElevationHeightOutlet InvertLaidIn wall A-LOK GasketConnection2/3 High Benchingor As SpecifiedBaseHeightVariesVariesOutlet 0 MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION ADJUSTMENTRINGS9"G" SERIESGRADE ADJUSTMENT RINGSG rade Rings are used toadjust the top elevation ofthe cast iron or steel frameand cover to the finishedgrade of the SEALANT jointmaterial or TSS Gasketsare available to

9 Provide awatertight joint betweenthe cover and the gradering section."H" SERIESREF-32-12/06 CONCRETE Cover750mmDiameterH 300 F(226 kg)H 150 F(136 kg)HI 300(226 kg)90mm310225395685mmDiameterG 300 (206 kg)G 150(103 kg)114mmConcrete CoverG 75 (52 kg)G 375(258 kg)37530015075 MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION "HR" SERIESGRADE ADJUSTMENT RINGS"F" SERIESREF-08/08765 Diameter1473001501060HR 300(305 kg) 150(152 kg) 300(355 kg) 150(178 kg) PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION 1050mm DIAMETER FLAT TOP MANHOLEREF-35-10/0610G 75G 150G 300G 375 Cover TypeH 300 FH 150 FHI 300 AGC 175 Grade RingAHC 300 Cast Iron Frame and Cover as SpecifiedFlat Top Cover - _____AGC 175 AHC 300AI 250AI 500AI 750AI 1000AI 1250 APB 500 MonoAPB 750 APB 1000 APB 1250 APB 1500 Grade Rings - _____ (see chart below)Intermediate Sections - _____Base Section - _____1067mm Diameter685mm DiameterTSS Gasket JointPage 9 Page 15 Page 14 Page 13 MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION 1050mm DIAMETER CONE TOP MANHOLEREF-34-10/06 Cast Iron Frame and Cover as SpecifiedGrade Rings - _____("H" Series)

10 AH 900 Eccentric Cone - _____TSS Gasket JointIntermediate Sections_____AI 250AI 500AI 750AI 1000AI 1250 Base Section _____750mm Diameter1050 DiameterAPB 500 APB 750 APB 1000 APB 1250 APB 1500 Page 9 Page 14 Page 14 Page 13 MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION Pre-Benched BaseWall and bottom cast as a single unit. Factory benching placed to suit size and location. Also availablewithout benching. Specify "Bottom Only".Inside Diameter:1067mmWall Thickness:114mmMaximum Pipe Size:c/w A-LOK gasket connection - 525mm CONCRETE * Laid Height estimate only. Dependant on pipe size and Base Height*Laid HeightWeightSectionmmmmkgAPB 750 750 mm 640 mm1270 kgAPB 10001000 mm 890 mm1520 kgAPB 12501250 mm1140 mm1770 kgAPB 15001500 mm1390 mm2020 kg12 REF-39-10/06 MANHOLESSHAW PIPE PRODUCT GUIDE AND TECHNICAL REFERENCE MANUALCONCRETE MANHOLESSECTION Diameter ManholeSections and Eccentric Cone TopsECCENTRIC CONE AH 900:Inside Diameter:1067mmWall Thickness:114mmLaid Height:900mmWeight:1000kgBOTTOM/INTERMED IATE SECTIONS:Inside Diameter:1067mmWall Thickness:114mmAvailable with in-wall A-LOK gasket or rough cuthole connections.


Related search queries