Example: bachelor of science

Configurable Packaged Air Handling Equipment - Valent Air

PRODUCTS VPR SERIES VPRX SERIES VPRE SERIES VPRP SERIES VPRC SERIES VRC SERIESC onfigurable Packaged Air Handling Valent ADVANTAGE Quality, reliability, flexibility, and supportQUALITYT horough factory run-testing. After assembly, every unit is energized and rigorously tested for an average time of 90 minutes. Testing verifies proper operation: Refrigeration testing at multiple conditions to evaluate superheat and subcooling performance Heat testing throughout heating operating range Electrical testing of component continuity and phasing Supply and exhaust fan testing for proper operation Valent manufactures highly Configurable Packaged air Handling systems. At our core is a commitment to initial quality, long-term reliability, application flexibility, and dedicated product casing sizes and pre-engineered options fit a wide range of applications. Multiple heating and cooling configurations allow stand-alone operation or connection to a central system Multiple energy recovery options Multiple duct connection optionsVPR Series with 352 casing, EC-driven condenser fans, 10:1 turndown gas heat, and modulating hot gas reheatOn the cover: VPRC Series with 210 casing, enthalpic core heat exchanger, indirect gas heat, electric preheat, and modulating hot gas reheatRELIABILITYSafe, consistent lifetime performance.

manufactures highly configurable packaged air handling systems. At our core is a commitment to initial quality, long-term reliability, application flexibility, and dedicated product support.

Tags:

  Handling, Packaged, Equipment, Packaged air handling equipment

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Configurable Packaged Air Handling Equipment - Valent Air

1 PRODUCTS VPR SERIES VPRX SERIES VPRE SERIES VPRP SERIES VPRC SERIES VRC SERIESC onfigurable Packaged Air Handling Valent ADVANTAGE Quality, reliability, flexibility, and supportQUALITYT horough factory run-testing. After assembly, every unit is energized and rigorously tested for an average time of 90 minutes. Testing verifies proper operation: Refrigeration testing at multiple conditions to evaluate superheat and subcooling performance Heat testing throughout heating operating range Electrical testing of component continuity and phasing Supply and exhaust fan testing for proper operation Valent manufactures highly Configurable Packaged air Handling systems. At our core is a commitment to initial quality, long-term reliability, application flexibility, and dedicated product casing sizes and pre-engineered options fit a wide range of applications. Multiple heating and cooling configurations allow stand-alone operation or connection to a central system Multiple energy recovery options Multiple duct connection optionsVPR Series with 352 casing, EC-driven condenser fans, 10:1 turndown gas heat, and modulating hot gas reheatOn the cover: VPRC Series with 210 casing, enthalpic core heat exchanger, indirect gas heat, electric preheat, and modulating hot gas reheatRELIABILITYSafe, consistent lifetime performance.

2 Reliability is enhanced through: Best-in-class components including Digital ScrollTM and inverter scroll compressors, modulating direct-drive fans, and 2" foam injected double wall casings Low maintenance requirements including energy recovery options with no moving parts Dependable controls platformsSUPPORTD edicated pre- and post-sale application engineering support. We are here to help you with: Design decisions Installation guidance Ongoing operation and maintenance Multiple preconfigured platforms and application-specific solutionsAIR HANDLERSVPR AND VPRX SERIESThe VPR and VPRX are capable of cooling, heating, and dehumidifying a wide range of entering air loads up to 100% outdoor air. In applications requiring powered exhaust, the VPRX offers modulating exhaust fans for pressure relief and economizer RECOVERY AIR HANDLERSV alent's rotating enthalpy wheels recover up to 70% of return-air energy, and slide out for easy access. Valent 's highly Configurable air Handling systems are available in five casing sizes and include multiple cooling, dehumidification, heating, energy recovery, control, filtration, and duct connection 's flat plate heat exchangers have no moving parts and require minimal maintenance.

3 They both have extremely low airstream cross-contamination flat plate heat exchangerEnthalpic core heat exchanger detailVRC Series remote condenser with EC-driven condenser fan optionVPRE SERIESThe VPRE expands upon the VPR Packaged platform to include an air-to-air enthalpy wheel and powered exhaust fan section. Two enthalpy wheel types are available: A lightweight polymer wheel with silica gel desiccant, and an aluminum wheel with molecular sieve SERIESWhen recovering sensible and latent energy is a priority but the maintenance requirements of an enthalpy wheel are unwanted, the VPRC with its enthalpic core heat exchanger is an excellent alternative. The enthalpic core heat exchanger has a exhaust air transfer ratio (EATR) as determined by AHRI 1060, and can safely handle accumulated condensate without sustaining frost SERIESIn applications where sensible-only energy recovery is desired, the VPRP delivers with an all-aluminum flat plate heat exchanger that has a low pressure drop and an extremely low cross-contamination rate.

4 Although commonly used in dry climates, the VPRP is also effective in high humidity or polluted spaces where airstream cross-contamination is CONDENSERVRC SERIESVRC remote condensers can be paired with select Valent air handlers. Compressors remain mounted in the indoor air handler for reliability and piping simplification, eliminating the need for a third refrigeration line on circuits with hot gas VPRE and VPRC Series air handlers are AHRI 1060 Certified as Packaged energy recovery , COOLING, DEHUMIDIFICATION OPTIONS Multiple options for stand-alone operation or connection to a central systemHE AT ING INDIRECT GAS FURNACE Standard construction includes 409 stainless steel burner tubes appropriate for 100% outdoor air applications Modulation range: 5:1 turndown standard 10:1 turndown optionELECTRIC SCR-modulated electric resistance heaterT EMPER ATOR Hybrid heating system pairing a 5:1 modulating gas furnace with a small SCR electric heater for total capacity modulation On-board controls operate in one of three heating modes.

5 Modulating electric resistance Modulating indirect gas furnace Full-fire indirect gas furnace plus modulating electric resistanceHOT WAT ER Designed for connection to an existing hot water loopSTEAM Designed for connection to an existing steam boilerCOOLING AND DEHUMIDIFICATIONAIR COOLED DIRECT EXPANSION Available in Packaged or split configurations Fully functional factory tested R-410A refrigeration system Two coil sets offered: 6-row for greater dehumidifica-tion capacity in 100% outdoor air applications 4-row for improved efficiency in mixed-air applications Capacity modulation options: Digital ScrollTM compressor utilizing loading and unloading for modulation Inverter scroll compressor utilizing variable speed modulation resulting in higher part-load performance Condensing fan options: Staged AC condenser fans with one VFD-modulated fan for refrigerant pressure control All modulating EC condenser fans with sound reducing blades for improved dehumidification performance, higher efficiency, and lower radiated sound Modulating hot gas reheat option recycles compressor exhaust energy to reheat cooled airCHILLED WATER 6- or 4-row coil depth with variable fin spacing to match the application Internal piping routed to an internal vestibule or piped out the unit's sideHE AT ING A ND COOLINGWATER SOURCE HEAT PUMP Coaxial water-to-refrigerant coil (R-410A)

6 Condenses in cooling mode and evaporates in heating mode Heat, cool, and dehumidify up to 100% outdoor air at start-up temps to 5 F Operates on boiler-tower or geothermal water loops Coaxial heat exchanger suitable for low entering geothermal water temperaturesAIR SOURCE HEAT PUMP Built on the same platform as Valent 's Packaged air cooled DX system Heat pump reversing cycle moves heat from outdoor air to supply air Provides heating when outdoor temps are as low as 17 F before switching to auxiliary heat Defrost cycles initiate based on low suction temperature and outdoor air dew point, not a timer, reducing the number of defrost cycles Valent 's water source heat pumps have coaxial water-to-refrigerant coils that are more freeze tolerant than traditional brazed plate heat exchangers. AND OPTIONS Pre-engineered components and multiple options provide application flexibility POWER/CONTROLSP ower 2 08, 230, 460, or 575 V 3-phase 6 0 Hz input Single-point power P hase and voltage monitoringControlsFull controls Microprocessor controls all internal components and sequences S et point communication via BAS Factory control sequences includedControls Lite Microprocessor controls refrigeration components H eating and ventilation component control by others I deal for control sequence customizationOptions GFCI outlet Dual-point power Breaker disconnect Cabinet heater S upply fan, exhaust fan, and damper modulation sequences FANSD irect drive plenum fans N o belts, wheels.

7 Or pulleys resulting in reduced maintenance and increased efficiency Lightweight wheels with backward curved or airfoil blades U p to three fans in parallel to match airflow requirementStandard VFD Simple airflow adjustment S oft start improves motor life C onstant or variable volume flowOptions I nlet cone airflow monitoring S haft grounding rings Vibration isolation HE AT ING In direct gas furnace Temperator Electric heater H ot water coil Steam coil A ir source heat pump Water source heat pump COOLING Packaged DX Split DX A ir source heat pump Water source heat pump Chilled waterOptions H ot gas reheat coil E lectroFin coil coating S tainless steel casing Compressor isolation valves Sight glasses DUCT CONNECTIONSS upply air B ottom or sideReturn air V PR: Bottom or end VPRX: Bottom E RV: Bottom or sideOutdoor air E nd, with hood or duct flangeExhaust air V PRX: End with hood E RV: One or both sides with backdraft damper FILTRATIONS upply air 2 " MERV 8 4 " MERV 8, 11, or 14 Outdoor air (ERV) 2 " aluminum or MERV 8 Exhaust air (ERV)

8 2 " aluminum or MERV 8 Hood 1" aluminumOptions F ilter pressure switch Filter pressure Magnehelic gage ENERGY RECOVERYType and media P olymer enthalpy wheel with silica gel desiccant Aluminum enthalpy wheel with molecular sieve desiccant A luminum sensible flat plate heat exchanger P olymer enthalpic core heat exchangerDesign E xhaust and outdoor air filtration Wheel cassettes slide out for cleaning A ccess panels above and drain pans under heat exchangers for cleaningOptions Electric preheater V FD for enthalpy wheel speed modulation B ypass damper for heat exchangers in economizer mode CONSTRUCTIONC asing 2 " double wall R-12 foam insulation Pre-painted exterior Galvanized interior H inged access doors with lockable handlesDampers Low-leakage blades Dedicated modulating actuator O utdoor air standard on all unitsOptions S tainless steel interior Airfoil blades Aluminum or stainless steel damper construction Outdoor air measurement stationABCDEFHGABCEFGHDVPRE Series with 210 DATAVPR, VPRX, VPRE, VPRP, VPRC CASINGV10110210310352 AIRFLOWM inimum(cfm)5506251, 25 03,12 53,750 Maximum(cfm)3,0004,0008,00012,00018,000 COOLING TYPE and NOMINAL TONSP ackaged air cooled3-row coil44-row coil5, 84-row coil 10, 13, 16, 18, 204-row coil25, 30, 354-row coil30, 40, 504-row coil5, 6, 76-row coil5, 8, 106-row coil10, 13, 16, 18, 20, 256-row coil25, 30, 35, 406-row coil30, 40, 50, 60, 70 Split air cooled (with VRC casing)

9 4-row coil5, 84-row coil 10, 13, 16, 18, 204-row coil25, 30, 35 6-row coil5, 8, 106-row coil10, 13, 16, 18, 20, 256-row coil25, 30, 35, 40 Water source heat pump 5, 8, 1010, 13, 16, 18, 20, 2525, 30, 35, 4030, 40, 50, 60 Air source heat pump 5, 8, 1010, 13, 16, 18, 20, 25 Chilled water 4- or 6-row coil4- or 6-row coil4- or 6-row coil4- or 6-row coilCOOLING COMPONENTSD igital ScrollTM compressor StandardStandardStandardStandardInverter scroll compressorStandardOptionalOptionalOption alOptionalCompressor(s) modulation range a21 100%25 100%12 100%6 100%6 100%Modulating hot gas reheatOptionalOptionalOptionalOptionalOp tionalStaged AC condensing fans StandardStandardStandardStandardModulati ng EC condensing fansStandardOptionalOptionalOptionalOpti onalINDIRECT GAS FURNACEM inimum (MBh)75100200400600 Maximum (MBh)2002004008001, 2 0 0 Turndown5:1/10:1 c5:1/10:1 c5:1/10:1 C5:1/10:110:1 ELECTRIC HEATM inimum (kW) 10154050 Maximum(kW) 50125150200 SCR modulation StandardStandardStandardStandardOTHER HEATHot water XXXXT emperator XXX Refer to Valent CAPS selection software or the Valent Mechanical IOM for additional Modulation range based on Digital ScrollTM compressor(s).

10 Inverter scroll modulation range may Available upon requestc LP turndown: 3:1/6 WEIGHTS (lbs)110 CASINGAir-cooled DXSplit air-cooled DXAir source heat pumpWater source heat pumpChilled water5810581058105810 SLVPR1,8 0 01,8 0 01,9001,70 01,70 01,70 01,9001,9002,0001,5001,6 0 01,70 01,5001,6 0 0 VPRX2,10 02,10 02,2002,0002,0002,0002,2002,2002,3001,8 0 01,9002,0001,8 0 01,900 VPRE2,5002,6002,7002,4002,5002,5002,6002 ,7002,8002,2002,4002,5002,2002,400 VPRP2,9003,0003,10 02,8002,9002,9003,0003,10 03,2002,6002,8002,9002,6002,800 VPRC2,7002,8002,9002,6002,7002,7002,8002 ,9003,0002,4002,6002,7002,4002,600 VRC 600600700 Air-cooled and air source heat pump units estimated with 200 MBh indirect gas furnace. Chilled water units estimated with hot water CASINGAir-cooled DXSplit air-cooled DX101316182025101316182025 VPR2,6002,7002,9002,9003,2003,3002,3002, 4002,5002,5002,7002,700 VPRX3,0003,10 03,2003,3003,7003,8002,7002,8002,8002,90 03,2003,200 VPRE3,7003,7003,9004,0004,3004,5003,4003 ,4003,5003,6003,8003,900 VPRP4,0004,10 04,2004,3004,7004,8003,7003,8003,8003,90 04,2004,200 VPRC3,8003,9004,0004,10 04,5004,7003,5003,6003,6003,7004,0004,10 0 VRC 9001,0001,10 01,10 01,2001, 3 0 0 Air source heat pumpWater source heat pumpChilled water101316182025101316182025 SMLVPR2,7002,8003,0003,0003,3003,4002,10 02,10 02,2002,3002,4002,4002,0002,10 02,200 VPRX3,10 03,2003,3003,4003,8003,9002,5002,5002,50 02,7002,9002,9002,4002,5002,700 VPRE3,8003,8004,0004,10 04,4004,6003,6003,5003,5003,8004,0004,10 03,10 03,2003,300 VPRP4,10 04,2004,3004,4004,8004,9005,0004,9004,80 05,2005,5005,6003,4003,5003,700 VPRC3,9004,0004,10 04,2004,6004,8006,2006,10 05,9006,4006,8007,0003,2003,3003.