Example: quiz answers

Cost Schedule 2017 - sfdbi.org

cost Schedule TECHNICAL SERVICES DIVISION2017 Prepared by :2017 cost Schedule TABLE OF CONTENTSL etter from Director ..iSection I - General Notes ..1 Section II - Tenant Improvement .. 2 Section III - Seismic Retrofit .. 3 Section IV - Fire Protection Systems ..5 Section V - General Items Applicable to All Occupancies ..8 Section VI - Base Costs of Various Occupancies (in New Buildings)..14 Section VII - Additional Costs Items: ..27 Applicable to Occupancies A, B, E, F, H, I, L, M, R and SSection VIII - Mechanical Equipments ..29 Section IX - Abbreviations ..31ii2017 cost SCHEDULEI GENERAL NOTES1 This Schedule is to be used in calculating a building's valuation for building permits and related fees posted in the City and County of San Francisco A valuation based on this table represents the valuation at the completion of all construction work authorized

2017 COST SCHEDULE II 1 Estimated construction costs for all occupancies, except R occupancies, are presumed to be without tenant improvements (core and shell). 2 Special costs (bank safe, mahogany paneling, marble finish, etc.) are to be added to the tenant improvement or site permit addendum costs. 3 The total cost of tenant improvement for first time improvement in a new nonresidential

Tags:

  Cost

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Cost Schedule 2017 - sfdbi.org

1 cost Schedule TECHNICAL SERVICES DIVISION2017 Prepared by :2017 cost Schedule TABLE OF CONTENTSL etter from Director ..iSection I - General Notes ..1 Section II - Tenant Improvement .. 2 Section III - Seismic Retrofit .. 3 Section IV - Fire Protection Systems ..5 Section V - General Items Applicable to All Occupancies ..8 Section VI - Base Costs of Various Occupancies (in New Buildings)..14 Section VII - Additional Costs Items: ..27 Applicable to Occupancies A, B, E, F, H, I, L, M, R and SSection VIII - Mechanical Equipments ..29 Section IX - Abbreviations ..31ii2017 cost SCHEDULEI GENERAL NOTES1 This Schedule is to be used in calculating a building's valuation for building permits and related fees posted in the City and County of San Francisco A valuation based on this table represents the valuation at the completion of all construction work authorized by a building permit.

2 Permit fees are based on a percentage of this valuation. These valuations are not to be used as accurate guides to the actual cost of construction; for actual construction cost estimates for any project please consult a contractor, a design professional or a cost Building permit, building plan review fees and other related fees shall be based on the date of permit application, adjusted based on subsequent revisions. Building floor area shall be calculated in accordance with the definitions contained in Chapter 2 of the San Francisco Building This Schedule is updated each year, or as otherwise directed by the Building Inspection Commission.

3 The valuation data is based on information provided by a variety of sources, including without limitation, local contractors, design professionals, cost estimators or nationally published construction cost data books or All unit prices are based on the gross floor area, unless noted otherwise. 5 Add caisson or pile cost by footage plus set-up cost 6 Where applicable, interpolate for intermediate cost SCHEDULEII1 Estimated construction costs for all occupancies, except R occupancies, are presumed to be without tenant improvements (core and shell). 2 Special costs (bank safe, mahogany paneling, marble finish, etc.)

4 Are to be added to the tenant improvement or site permit addendum The total cost of tenant improvement for first time improvement in a new nonresidential building shall be calculated when the tenant improvement application or site permit addendum is submitted per square foot of gross floor area at ..$ (This includes partitions, finishes, ceilings, mechanical, plumbing and electrical. Deduct the following itemized costs if such work are excluded.) UnitAmount (i) Partitions per sq. ft.$ (ii) Finishesper sq. ft.$ (iii) Ceilingsper sq. ft.$ (iv) Non-residential mechanical and plumbing work per sq.

5 Ft.$ (or may be computed on an item-by-item basis as detailed in this cost Schedule ). (v) Non-residential electrical workper sq. ft.$ (lighting, distribution & control, including low voltage)4 The cost of removal of non-bearing partitions shall be calculated per square foot basis $ TENANT IMPROVEMENTSECTION2017 cost SCHEDULESECTIONIII SEISMIC RETROFITUnitAmount1 For Bldg. originally constructed before 1917:per sq. ft.$ For Bldg. originally constructed between 1917 and May 31,1973 and: (A) less than 1171 sq.

6 Ft. in total floor area:per sq. ft.$ (B) 1171 sq. ft. or more in total floor area: Unreinforced Masonry per sq. ft.$ Wood Light Frame or Wood per sq. ft.$ Precast Concrete Tilt Up Walls or Reinforced Masonry with Metal or Wood Diaphragmper sq. ft.$ Concrete Moment Frame or Concrete Frame with Infill Concrete Shear Wallsper sq. ft.$ Steel Moment Frameper sq. ft.$ Steel Braced Frame or Steel Light Frameper sq. ft.$ Steel Frame with Infill Concrete Shear Wallsper sq. ft.$ Concrete Shear Wall or Precast Concrete Frame with Concrete Shear Walls or Reinforced Masonry with Precast Concrete Diaphragm or Steel Frame with Concrete Shear Wallsper sq.

7 Ft.$ For Bldg. originally constructed after May 31,1973 and: (A) less than 1171 sq. ft. in total floor area:per sq. ft.$ (B) 1171 sq. ft. or more in total floor area: Unreinforced Masonry per sq. ft.$ 32017 cost Schedule III (Continued)UnitAmount Wood Light Frame or Woodper sq. ft.$ Precast Concrete Tilt Up Walls or Reinforced Masonry with Metal or Wood Diaphragmper sq. ft.$ Concrete Moment Frame or Concrete Frame with Infill Concrete Shear Wallsper sq. ft.$ Steel Moment Frameper sq. ft.$ Steel Braced Frame or Steel Light Frameper sq.

8 Ft.$ Steel Frame with Infill Concrete Shear Wallsper sq. ft.$ Concrete Shear Wall or Precast Concrete Frame with Concrete Shear Walls or Reinforced Masonry with Precast Concrete Diaphragm or Steel Frame with Concrete Shear Wallsper sq. ft.$ :1. Seismic retrofits in this section include both foundation and superstructure and do not include architectural remodeling, disabled access improvements, hazarous material disposal, or historical building Unit prices are based on the gross floor Multiply the above unit cost by for floor at the ground For foundation retrofit only, use unit cost for excavation, reinforced concrete and drilled dowels with epoxy in Section cost SCHEDULESECTIONIVUnitAmountEmergency Communication System (ECS)per floor$5, Responder Radio Coverage System (ERRCS)each$105, Evacuation Mapseach$ Alarm Systems.

9 Fire Alarm Systems (New) Addressable Fire Alarm System with Horn (New)per sq. ft.$ Addressable Fire Alarm System with Speaker (New)per sq. ft.$ Conventional (Zoned) Fire Alarm System (New)per sq. ft.$ Alarm System Components for new construction(including wiring and conduit): FACP Installation + Programing (Conventional) each$1, FACP Installation + Programing (Addressable up to 256 Points) each$2, FACP Installation + Programing (Addressable up to 512 Points) each$4, Addressable System Node or Transponder Installation + Programingeach$2, Remote/Booster power supply Installation + Programingeach$1, Remote LCD Annunciator Installation + Programingeach$ Remote LED Annunciator Installation + Programing up to 50 LEDs each$1, Remote LED Annunciator Installation + Programing up to 100 LEDs each$2, Graphic Annunciator (Custom made)

10 Installation + Programingeach$4, Smoke/Heat Detector each$ Duct Detectoreach$1, Monitor/Control Moduleeach$ Manual pull stationeach$ PROTECTION SYSTEMS2017 cost SCHEDULEIV (Continued)UnitAmount Horn each$ Strobeeach$ Horn/Strobe each$ Speakereach$ Speaker/Strobeeach$ Remote test switch for duct detectoreach$ Remote indicator for duct detectoreach$ Door Holdereach$ FA Belleach$ Alarm Retrofit (including wiring and conduit) : Initiating device each$ Notification applianceeach$ Control unit or power supply (including programming)each$2, Extinguisher Systems: Clean Agent Suppression Systemeach$31, Preaction Sprinkler Systemeach$21, (Add cost of sprinkler per Section II)Fire Pump:500 GPMeach$80, GPMeach$85, GPMeach$100, GPMeach$119, GPMeach$130, GPMeach$224, cost SCHEDULEIV (Continued)UnitAmountFire Sprinkler Systems:Sprinkler System 10,000 or lessper sq.


Related search queries