CPAP - mercurymed.com

MERCURY MEDICAL Page 128(800) 835-MMED (727) 573-0088 FAX (800) 990-6375 CPAPN asal-Aire II Critical CareSingle-use cpap interface by InnoMedThe comfortable, economical solution to non-invasive ventilation!Advantages:.Can be worn for any duration withoutdiscomfort-no uncomfortable pressure points onthe Promotes patient compliance. Does not interfere with mouth. Built-in swivel. Completely assembled. Small, lightweight design. Saves shelf space. Disposable. pressure Bleed Port allows pressure monitoringor oxygen entrainment. 5 sizes: Small, Medium, Medium-Plus, Large,X-LargeSomething new isin the GaugePart No.

INCA Infant Nasal CPAP Assembly is the most respected CPAP (Continuous Positive Air Pressure) device among clinicians. INCA can be used with Bubble CPAP enabling you to

Tags:

  Pressure, Positive, Continuous, Bubbles, Cpap, Lasan, Bubble cpap, Nasal cpap, Continuous positive air pressure

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CPAP - mercurymed.com

1 MERCURY MEDICAL Page 128(800) 835-MMED (727) 573-0088 FAX (800) 990-6375 CPAPN asal-Aire II Critical CareSingle-use cpap interface by InnoMedThe comfortable, economical solution to non-invasive ventilation!Advantages:.Can be worn for any duration withoutdiscomfort-no uncomfortable pressure points onthe Promotes patient compliance. Does not interfere with mouth. Built-in swivel. Completely assembled. Small, lightweight design. Saves shelf space. Disposable. pressure Bleed Port allows pressure monitoringor oxygen entrainment. 5 sizes: Small, Medium, Medium-Plus, Large,X-LargeSomething new isin the GaugePart No.

2 #DT-X2007 Size Ordering InformationSize:Order #QuantitySmall#DT-CSM2 10/BoxMedium#DT-CMD3 10 #DT-CMP4 10/BoxLarge#DT-CLG510/BoxX-Large#DT-CXL6 10/BoxCPAP*MERCURY MEDICAL Page 129(800) 835-MMED (727) 573-0088 FAX (800) 990-6375 MACS is the nextgeneration cpap system for EMS/Hospital UseContinuous positive Airway pressure ( cpap )for use by mask orendotracheal includeCongestive Heart Failure (CHF), Asthma, Acute RespiratoryFailure (ARF), Trauma, COPD, Near Drowning or any patientwith severe breathing supports patients in respiratory distress who wouldotherwise require intubation.

3 EMS agencies with Mask cpap protocols have reported a substantial decrease in patientintubations with increased ER for everyone - MACS cpap system for the patient Demand flow system with minimal wasted oxygen Low patient Work of Breathing (WOB) with peak flow ofup to 140 L/min to meet patient needs Calibrated cpap control for stable pressure delivery Two oxygen levels to give only what is really needed for the healthcare provider Manometer to monitor patient pressure and effort Night visible pressure gauge for patient monitoring Compatible with all end tidal CO2monitoring systems Allows in-line medication nebulization for the budget Two oxygen levels - conserve oxygen with 65% setting.

4 Double the tank time Standardized inexpensive patient circuits with or without mask and head strap will save on operating costs Non-capital purchasing programs available to fit your budgetSpecifications MACS cpap SystemDescription All pneumatic design and built tough; no batteries required cpap control allows easy pressure adjustment to match patient requirements Demand flow system with automatic flow triggering; peak flow to 140 L/min Oxygen flow only as needed to match patient effort pressure displayed on night viewable manometer Gas supply 55 psi + 15 psi oxygen Size W x 8 D x H (9 cm x 20 cm x 17 cm) Weight 3 lbs ( kg) Classification according to MDD 93/42/EEC: IIb Meets international standards- ASTM F 920-85 Minimum Performance and SafetyRequirements for Resuscitators Intended for use withHumans- ISO 10651-5:2006 Lung ventilators for medical use -Particular requirements for basic safety and essentialperformance - Part 5.

5 Gas-powered emergencyresuscitators- IEC 60529:2001 Degrees of protection provided byenclosures, level IPX4 Control Settings CPAP0 to 20 cm H2O Oxygen65% or 100%Specifications are subject to change at any time without notice.#DH-58011 Disposable Patient Circuit 10/boxAdult/Pediatric 6 Length; Includes Large AdultFacemask and Accessories#DH-21040 Pole Mount Bracket for MACS#DH-21025 MACS Protective Boot with Shoulder Strap#DH-97032 MACS Service Manual#DH-21021 Travel Bag for MACS#DH-21085*Oxygen Hose Coiled 15 Length DISS Female xDISS Female (*Other Configurations Available)#53-4-0050-10 Test Lung, 1000cc*Items on this page may not be available for sale in all AccessoriesMERCURY MEDICAL Page 130(800) 835-MMED (727) 573-0088 FAX (800)

6 990-6375 cpap #EG-MC1001 Small cpap Nasal Cannula12/case#EG-MC1002 Medium cpap Nasal Cannula12/case#EG-MC1003 Large cpap Nasal Cannula12/case#EG-MC1011 Small cpap Cannula w/Cap12/case#EG-MC1012 Medium cpap Cannula w/Cap12/case#EG-MC1013 Large cpap Cannula w/Cap12/case#EG-MC1111 Small/Medium cpap Cap Only 12/case#EG-MC1212 Large cpap Cap Only12/caseMEDICOMP molds the cpap Nasal Cannulas from soft pliant silicone for the utmostpatient comfort. The two short angled tubes insert easily into the infants nostrils. Andthey can remain in place for prolonged periods without cpap Nasal Cannulas are held in place with the specially designed infant capshown below.

7 The cap is made with integral cloth ties that attach to correspondingholes in the cpap Cannula. This unique arrangement holds tubes securely in theinfants nostrils while providing patient warmth. The cloth tie design also eliminatesthe problems of torn skin and pulled hair commonly encountered with adhesive tapeattachment staffs report fewer dislodgments and less patient irritation when usingMEDlCOMP s cpap Nasal Cannula. The MEDICOMP design allows your nursing staffto perform routine care procedures without interrupting cpap therapy.

8 This frees upstaff for Single-Patient System#AF-5-16000 Modified Mapleson D System with Norman elbow allows for addition of oxygen at patient connector Detachable 6 -24 expandable tubing with wye for easy access to adjustable PEEP Valve and IL breathing bag Valve on fixed wye connector allows clinician to dial in desired amount of cpap 7 feet oxygen tubing connects Norman elbow with universal connector Single patient use Individually packaged 10 per caseThis product contains natural latex FLEX-C-PAPsystem may be usedwith SHER-I-BRONCH endobronchial tubes toperform one lungventilation.

9 MERCURY MEDICAL Page 131(800) 835-MMED (727) 573-0088 FAX (800) 990-6375 cpap /InfantINCA Infant Nasal cpap Assembly is the most respected cpap ( continuous positive AirPressure) device among clinicians. INCA can be used with bubble cpap enabling you tobring the benefits of bubble cpap to neonates in your care. Five incrementally-close, anatomically proportional nasal cannulae sizes for a custom fit Clear, extra-soft cannulae to help maintain tissue integrity Stay-Flex tubing for custom shaping and maximum stability Foam block retainers for secure placement and stabilityOrdering Information#2627-44-2707 INCA Nasal Cannulae Set Fr#2627-44-2709 INCA Nasal Cannulae Set 9 Fr#2627-44-2710 INCA Nasal Cannulae Set Fr#2627-44-2712 INCA Nasal Cannulae Set 12 Fr#2627-44-2715 INCA Nasal Cannulae Set 15 Fr#2627-44-0707 INCA Replacement Sections Fr#2627-44-0709 INCA Replacement Sections 9 Fr#2627-44-0710 INCA Replacement Sections

10 Fr#2627-44-0712 INCA Replacement Sections 12 Fr#2627-44-0715 INCA Replacement Sections 15 FrThe Hudson RCI infant nasal prong continuous positive airway pressure ( cpap ) cannula system is designed to reduce trauma associated with the delivery of infant nasal cpap . Hudson RCI cpap prongs are available as a system for use with a water seal or spring loaded valve or as a set for use with any mechanical ventilator. Soft anatomically curved prongs minimize nasal septal necrosis Six prong sizes fit a full range of infants (see sizing chart below).


Related search queries