For more than 60 THE ENVIRONMENT YOU NEEDTS9026 TS9053 TS9135 TS9430 ABOUT TERMAKST ermaks is one of the leading suppliers of laboratory drying ovens, laboratory incubators, cooling incubators and envi ronmental chambers in Scan dinavia. We enjoy a rapidly grow ing market worldwide, based on our selected distributors in Asia and Europe all with a good local knowled ge and a well established position within the supply of labora tory AS can look back on more than 60 years of ac 2 About Termaks 4 TS 9000 Series: Sterilizers Laboratory Drying Ovens 8 Technical specifications 9 B 9000 Series: Incubators, Bacteriological Cabinets 13 Technical specifications 14 KB 8000 Series: Cooling Incubators 17 Technical specifications 18 KB 8000F Series: Environmental Chambers 21 Technical specificationsTABLE OF CONTENTS tivity.

Li en 79 Li en,N9 Li e-N,99Li e5Nn Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and shelves are in stainless steel.

Tags:

  Environment, Needs, Create, Creates the environment you need

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CREATES THE ENVIRONMENT YOU NEED - Termaks

1 For more than 60 THE ENVIRONMENT YOU NEEDTS9026 TS9053 TS9135 TS9430 ABOUT TERMAKST ermaks is one of the leading suppliers of laboratory drying ovens, laboratory incubators, cooling incubators and envi ronmental chambers in Scan dinavia. We enjoy a rapidly grow ing market worldwide, based on our selected distributors in Asia and Europe all with a good local knowled ge and a well established position within the supply of labora tory AS can look back on more than 60 years of ac 2 About Termaks 4 TS 9000 Series: Sterilizers Laboratory Drying Ovens 8 Technical specifications 9 B 9000 Series: Incubators, Bacteriological Cabinets 13 Technical specifications 14 KB 8000 Series: Cooling Incubators 17 Technical specifications 18 KB 8000F Series: Environmental Chambers 21 Technical specificationsTABLE OF CONTENTS tivity.

2 The company was found ed in 1952, and the first years it supplied exclusively the Norwegian market with envi ronmental laboratory eq uip ment. From the base in Bergen on the Norwegian West coast the activity has increased considerably so today we ex port our products worldwide. Approximately 80% of the turnover is export. Termaks products are marke ted by a net of well esta blished and skilled dis tri bu tors who are able to give excellent support regarding both sales and service. BERGEN, 3TS9026 TS9053 TS9135 TS9430 Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 housing and shelves are in stainless steel. Externally, the cabi-nets are constructed of electrolytically galvanized steel sheets, coated with a grey epoxy polyester paint (RAL 7035).The three smallest models are table models that are stackable. They can be wall mounted using brackers.

3 The largest model is freestanding and has adjustable 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Automatic safety thermostat Increased safety simpler to operate LCD display Explanatory text simpler to operate Motorised valve Automatic shut off end of cycle and overheating Touch buttons Extended lifetime in humid surroundings Software Alternates between two temperatures at specified time, daily or weekly Extended temperature range Can operate down to 2 C above ambient temperature Keypad with PIN code Prevents undesirable settings Potential free alarm contact Can connect to external alarm system USB outlet Simple updates possible via PC 10 speed fanKEY FEATURES4 the System Setup, one of two timer systems can be chosen:STANDARD TIMER (DEFAULT):JJCan be set to maximum 99 hours and 59 counting down when the Set Temperature is the case of power failure, lasting more than 5 minutes, the counting will restart from the Fan and Air valve are controlled as illustrated the chamber shall run without any timing, the time setting should be set to 00h 00m.

4 This will avoid accidental start of the TIME PROGRAM:JJOptional, can be chosen in the System Setup it possible to operate the chamber at two different extra temperature is named Temperature B in the Temperature B to 000 C means that heater and fan are turned off in that period (Sleep Mode).JJStart- and end Time for Temperature B can be set to any time during the week or on daily choosing xx instead of a specified day, the change will occur daily at the given Real Time Clock is backed up for about 10 minutes if power fails. A warning is given if adjustment is flashingLED Lit180 CFan OffFan OnValve ClosedValve in Set PositionLED FlashingFan OffValve ClosedCycle TimeActual Setting Temperature180 CActual Setting Cycle Time01h 30mSTANDARD TIMER, 5 TermakasrmT AkSl:mSe:mFAxmFaE-A:irETTS9026 TS9053 TS9135 TS9430 THE FANJJA djustable speed, 1 to heating up, settings lower than 6 will be for about 30 seconds when the door is opened while running at set temperature.

5 This function is disabled for 4 minutes after last door opening or after last Air Valve reduce speed, or even stop, if operating at a temperature close to the ambient AIR VALVEJJA djustable opening in steps of 10% (00 = closed, 100 = open).JJMovement may be 10 sec be open when used for drying automatically when heating up, when a timer cycle is completed or in Sleep mode (Real Time Program).PIN CODEJJO ptional system to stop unwanted settings from unauthorized personal pin code can be entered during the first 30 seconds after turning the chamber on with the main switch or waking up from Standby Mode. Actual code is displayed after pressing the Set key in that period. A unique code can be chosen in the range from 001 to 999. JJ000 means deactivated Pin Code activated, Pin Code? will be displayed in the left code must be set by Up/Down Keys, followed by pressing the Enter system will remain opened for 30 seconds after the last key can be acknowledged by the Standby Key even if the keys are assembled with door lock system, the door will be locked as the keys are C100 C180 CMonTueWedThuFriSatSunMonActual Setting Temp B StartTimeMo 19:45 Actual Setting Temp B EndTimeFr 05:00 Actual Setting Temperature B100 CActual Setting Temperature180 CWEEK CYCLE, EXAMPLEA ctual Setting Temperature B100 CActual Setting Temperature180 CTemperatureTime180 C100 CMonTueWedThuFriSatSunMonActual Setting Temp B StartTimexx 16:00 Actual Setting Temp B EndTimexx 06:00 DAY CYCLE, EXAMPLE6 way to shut down the chamber.

6 Keeps the real time clock off Heaters, Fan and the Standby Key for about 3 seconds until the backlight in the display turns Standby LED turns on when the key is chamber can be restarted by pressing the Standby Key for 3 right display will show for a moment during number of alarm situations may occur, listed warning is given in the lower line of the left backlight starts flashing and the buzzer starts sounding whenever an alarm flashing and the sound can be stopped by pressing the Standby OUTPUTSJJA potential free contact is available for external use (see drawing Main Switch and External Connections).JJThe output switches when an alarm situation occurs, one minute immediately at power return to normal when the alarm situation is THERMOSTATJJA utomatic system, preventing risky temperatures in the case of a controller independent from the ordinary temperature control systemJJAutomatically adjusted whenever a new Temperature Set is enteredJJAdjustable limit (offset from target) JJCuts power to the heaters when the limit is exceededJJGenerates an alarm warningJJTurns to normal when the temperature has dropped C below the limitCALIBRATIONTwo calibration constants can be adjusted in order to bring the temperature measurement equal to the true value according to a control 7 TermakasrmT AkSl:mSe:mFAxmFaE-A.

7 IrETTEMPERATURE CONTROLTS 9026TS 9053TS 9135TS 9430 Variation+ / - C1111 Deviation (spatial)+ / - %1,51,51,51,5 Readability / Setability C1111 Range Ctb-250tb-250tb-250tb-250 Sensor thermocouple K YesYesYesYesControllerPIDPIDPIDPIDD isplayLCDLCDLCDLCDTIMER Standard hours / minutes99h / 59m99h / 59m99h / 59m99h / 59mReal time program *YesYesYesYesSAFETYA larm flashing / Acoustic Yes YesYes Yes Alarm limit settable YesYes Yes Yes Automatic safety setting YesYes Yes Yes FEATURESFan speed control 1/101/101/101/10 Exhaust valvemm30 3030 3030 3060 60 Ventilation slide0-100 %YesYesYesYesData Port, Serial USBYesYesYesYesPot. free alarm outputYesYesYesYesSHELVESS tandard / Maxpcs2/72/83/163/23 Dimensions W Dmm346 235434 325534 325602 570 Max load pr shelfkg20202030 Permitted total loadkg505070100 HEATINGH eating up time to 250 Cmins40506520 Heat transfer at 250 CW4004607101500 Air changesHz110502060 POWERN ominal PowerW930143014304600 Nominal voltageV230,1~230,1~230,1~230/400,3~Freq uencyHz50/6050/6050/6050/60 DIMENSIONSE xterior W D Hmm490 480 500580 575 550680 675 750753 845 1360 Interior W D Hmm350 255 300440 345 350540 455 555610 600 1180 Volumelitres2653135430 WEIGHTS / VOLUMENet weightkg203552120 Shipping weightkg254060140 Shipping volumedm30,213505581280 STERILIZERS LABORATORY DRYING OVENStb = 2 C ABOVE AMBIENT* CAN BE SET AT TWO TEMPERATURES, DAILY OR WEEKLYTECHNICAL SPECIFICATIONS8.

8 BACTERIOLOGICAL CABINETSS eries B9000 consists of four different cabinets ranging in size from 23 litres to 420 litres. Interior housing and shelves are in stainless steel. All cabinets are equipped with a glass inner , the cabinets are constructed of electrolytically galvanized steel sheets, coated with a grey epoxy polyester paint (RAL 7035).The three smallest models are table models that are stackable. The largest model is freestanding and has adjustable 9000 SERIES:INCUBATORS, BACTERIOLOGICAL CABINETS Automatic safety thermostat Increased safety simpler to operate LCD display Explanatory text simpler to operate Touch buttons Extended lifetime in humid surroundings Software Alternates between two temperatures at specified time, daily or weekly Extended temperature range Can operate down to 2 C above ambient temperature Keypad with PIN code Prevents undesirable settings Potential free alarm contact Can connect to external alarm system Sterilizing cycle Possible to sterilize USB outlet Simple updates possible via PC 10 speed fanKEY 9 TIMERSIn the System Setup, one of two timer systems can be chosen:STANDARD TIMER (DEFAULT).

9 JJCan be set to maximum 99 hours and 59 counting down when the Set Temperature is the case of power failure, lasting more than 5 minutes, the counting will restart from the Fan and Air valve (if assembled) are controlled as illustrated the chamber shall run without any timing, the time setting should be set to 00h will avoid accidental start of the TIME PROGRAM:JJOptional, can be chosen in the System Setup MenuJJMakes it possible to operate the chamber at two different temperaturesJJThe extra temperature is named Temperature B in the menusJJSetting Temperature B to C means that heater and fan are turned off in that period. (Sleep Mode)JJStart- and end Time for Temperature B can be set to any time during the week or on daily basisJJWhen choosing xx instead of a specified day, the change will occur daily at the given timeJJThe Real Time Clock is backed up for about 10 minutes if power fails.

10 A warning is given if adjustment is flashingLED CFan OffFan OnLED FlashingFan OffCycle TimeActual Setting Temperature37 CActual Setting Cycle Time01h 30mSTANDARD TIMER, EXAMPLEB9025 B9051 B9130 B942010 CYCLEJJA fixed sterilization cycle for the chamber is available, 180 C in 40 minutesJJStandard timer must have been chosen in the Setup MenuJJActs as Standard Timer, but temperature and time can t be adjustedJJThe cycle can be started by pressing Up, Down and Timer keys for 3 secondsJJThe message Sterilization appears in the left display and the Timer LED turns onJJHeating Up is displayed until the 180 C has been reachedJJTime Left (Minutes) will be displayed when the set temperature has been finished, Cycle Complete will be displayed and the LED starts flashingJJReturn to normal operation, timer or continuous, by pressing Timer key for 3 secTHE FANJJA djustable speed, 1 to When heating up, settings lower than 6 will be for about 30 seconds when the door is opened while running at set temperature.