1 For more than 60 THE ENVIRONMENT YOU NEEDTS9026 TS9053 TS9135 TS9430 ABOUT TERMAKST ermaks is one of the leading suppliers of laboratory drying ovens, laboratory incubators, cooling incubators and envi ronmental chambers in Scan dinavia. We enjoy a rapidly grow ing market worldwide, based on our selected distributors in Asia and Europe all with a good local knowled ge and a well established position within the supply of labora tory AS can look back on more than 60 years of ac 2 About Termaks 4 TS 9000 Series: Sterilizers Laboratory Drying Ovens 8 Technical specifications 9 B 9000 Series.
2 Incubators, Bacteriological Cabinets 13 Technical specifications 14 KB 8000 Series: Cooling Incubators 17 Technical specifications 18 KB 8000F Series: Environmental Chambers 21 Technical specificationsTABLE OF CONTENTS tivity. The company was found ed in 1952, and the first years it supplied exclusively the Norwegian market with envi ronmental laboratory eq uip ment. From the base in Bergen on the Norwegian West coast the activity has increased considerably so today we ex port our products worldwide.
3 Approximately 80% of the turnover is export. Termaks products are marke ted by a net of well esta blished and skilled dis tri bu tors who are able to give excellent support regarding both sales and service. BERGEN, 3TS9026 TS9053 TS9135 TS9430 Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 housing and shelves are in stainless steel. Externally, the cabi-nets are constructed of electrolytically galvanized steel sheets, coated with a grey epoxy polyester paint (RAL 7035).The three smallest models are table models that are stackable.
4 They can be wall mounted using brackers. The largest model is freestanding and has adjustable 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Automatic safety thermostat Increased safety simpler to operate LCD display Explanatory text simpler to operate Motorised valve Automatic shut off end of cycle and overheating Touch buttons Extended lifetime in humid surroundings Software Alternates between two temperatures at specified time, daily or weekly Extended temperature range Can operate down to 2 C above ambient temperature Keypad with PIN code Prevents undesirable settings Potential free alarm contact Can connect to external alarm system USB outlet Simple updates possible via PC 10 speed fanKEY FEATURES4 the System Setup, one of two timer systems can be chosen:STANDARD TIMER (DEFAULT).
5 JJCan be set to maximum 99 hours and 59 counting down when the Set Temperature is the case of power failure, lasting more than 5 minutes, the counting will restart from the Fan and Air valve are controlled as illustrated the chamber shall run without any timing, the time setting should be set to 00h 00m. This will avoid accidental start of the TIME PROGRAM:JJOptional, can be chosen in the System Setup it possible to operate the chamber at two different extra temperature is named Temperature B in the Temperature B to 000 C means that heater and fan are turned off in that period (Sleep Mode).
6 JJStart- and end Time for Temperature B can be set to any time during the week or on daily choosing xx instead of a specified day, the change will occur daily at the given Real Time Clock is backed up for about 10 minutes if power fails. A warning is given if adjustment is flashingLED Lit180 CFan OffFan OnValve ClosedValve in Set PositionLED FlashingFan OffValve ClosedCycle TimeActual Setting Temperature180 CActual Setting Cycle Time01h 30mSTANDARD TIMER, 5 TermakasrmT AkSl:mSe:mFAxmFaE-A:irETTS9026 TS9053 TS9135 TS9430 THE FANJJA djustable speed, 1 to heating up, settings lower than 6 will be for about 30 seconds when the door is opened while running at set temperature.
7 This function is disabled for 4 minutes after last door opening or after last Air Valve reduce speed, or even stop, if operating at a temperature close to the ambient AIR VALVEJJA djustable opening in steps of 10% (00 = closed, 100 = open).JJMovement may be 10 sec be open when used for drying automatically when heating up, when a timer cycle is completed or in Sleep mode (Real Time Program).PIN CODEJJO ptional system to stop unwanted settings from unauthorized personal pin code can be entered during the first 30 seconds after turning the chamber on with the main switch or waking up from Standby Mode.
8 Actual code is displayed after pressing the Set key in that period. A unique code can be chosen in the range from 001 to 999. JJ000 means deactivated Pin Code activated, Pin Code? will be displayed in the left code must be set by Up/Down Keys, followed by pressing the Enter system will remain opened for 30 seconds after the last key can be acknowledged by the Standby Key even if the keys are assembled with door lock system, the door will be locked as the keys are C100 C180 CMonTueWedThuFriSatSunMonActual Setting Temp B StartTimeMo 19:45 Actual Setting Temp B EndTimeFr 05.
9 00 Actual Setting Temperature B100 CActual Setting Temperature180 CWEEK CYCLE, EXAMPLEA ctual Setting Temperature B100 CActual Setting Temperature180 CTemperatureTime180 C100 CMonTueWedThuFriSatSunMonActual Setting Temp B StartTimexx 16:00 Actual Setting Temp B EndTimexx 06:00 DAY CYCLE, EXAMPLE6 way to shut down the chamber. Keeps the real time clock off Heaters, Fan and the Standby Key for about 3 seconds until the backlight in the display turns Standby LED turns on when the key is chamber can be restarted by pressing the Standby Key for 3 right display will show for a moment during number of alarm situations may occur.
10 Listed warning is given in the lower line of the left backlight starts flashing and the buzzer starts sounding whenever an alarm flashing and the sound can be stopped by pressing the Standby OUTPUTSJJA potential free contact is available for external use (see drawing Main Switch and External Connections).JJThe output switches when an alarm situation occurs, one minute immediately at power return to normal when the alarm situation is THERMOSTATJJA utomatic system, preventing risky temperatures in the case of a controller independent from the ordinary temperature control systemJJAutomatically adjusted whenever a new Temperature Set is enteredJJAdjustable limit (offset from target)