Transcription of D Meter Sockets-E - tnb.ca
1 SocketsTable of Contents20 A 600 V CL, CT, CT-SWL Series .. D3 D5100 A 600 V R3, BA3 Series .. D6 D7100 A 600 V King Size BE1 Series .. D8100 A per Position 200 A 600 V BE2, BEC Series .. D9 D10100 A 600 V Polyphase PL17 Series .. D11100 A 120/240 V CO1 Series .. D12100 A per Position 120/240 V CO1 Multi-Gang .. D13100 A 120/240 V HD Series .. D14200 A 600 V BQ, BP, BS2, MO2 Series .. D15 D25200 A per Position 200 A 600 V BD, BDA, BDC, BS4 Series .. D26 D29200 A per Position 400 A 600 V BSC4-G Series ..D30200 A 600 V Polyphase PL27 Series .. D31200 A 120/240 V PE2-CS Unit Pedestal .. D32 D33200 A 120/240 V CO2 Series .. D34 D35200 A 120/240 V CO22, CO23, CO24 Series ..D36200 A 120/240 V CO22-U, CO23-U, CO24-U Series .. D37400 A 120/240 V CO42 Series.
2 D38200 A 120/208 V CO27 Series ..D39320 A 600 V BP320 Series ..D40400 A 600 V FA4B-6T .. D41400 A 120/240 V JS4 Series .. D42 D43 Typical Wiring Diagrams ..D44 D45 Accessories .. D46 D52 Meter Covers ..D53 Service Masts .. D54 D63 Pole Line Hardware .. D64 D73 Carlon Nonmetallic Conduits .. D74 D76 Carlon PV-Mold .. D77 D81E-Z-Ground Grounding Systems .. D82 D89E-Z-Ground Types of Connectors .. SocketsCL Series20 A 600 V; Transformer Rated Product Specifications Conductor range: 14-10 AWG Aluminum tunnel type connectors for both load and line sides Circuit closing feature to short out current transformer upon removal of Meter For overhead hub opening only Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: Sask., Man., Ont.
3 , , , , Nfld. Approved for copper onlyCat. (in.)Weight JAWCL4-VCircuit closing on left side9-1/47-5/83-11 closing on left side, no hub opening5 JAWCL5-VCircuit closing on left side (Lower right hand jaw is a support only)9-1/47-5/83-11 JAWCL6-LRVC ircuit closing both left and right sides9-1/47-5/83-11 SizeKnockout3/4, 1 and 1-1/4 PlacesTrade SizeKnockout1-1/4 and 1-1/2 PlaceTrade SizeKnockout1/2, 1 and 1-1/4 Places1-3/4 Size Knockout 1/4 Place(CL4-V) (CT113) Meter SocketsCT Series20 A 600 V; Transformer Rated c/w Compartment for Test SwitchLower test switch compartment cover securely held by upper cover and a out device with an enlarged pad hole ( in. dia.) Approved for copper onlyCat. (in.)Weight JAWCT105-LBC Hydro approved with SWL cover with enlarged padlock hole19-1/811-13/165-7 JAWCT108-LBC Hydro approved with SWL cover with enlarged padlock hole19-1/811-13/165-7 JAWCT113-LBC Hydro approved with SWL cover with enlarged padlock hole19-1/811-13/165-7 Approved for copper onlyCat.
4 (in.)Weight JAWCT104 Unwired unit with test switch provision19-1/811-13/165-7 JAWCT105 Unwired unit with test switch provision19-1/811-13/165-7 JAWCT108 Unwired unit with test switch provision19-1/811-13/165-7 JAWCT113 Unwired unit with test switch provision19-1/811-13/165-7 SizeKnockout 3/4, 1 and 1-1/4 Places3-5/8 Size Knockout 1/2 Place1-15/16 Size Knockout 1/2 Place19-1/8 Size Knockout 3/4, 1 and 1-1/4 PlacesProduct Specifications Conductor range: 14-10 AWG Tunnel type connectors for both load and line sides For underground service only Meter compartment cover overlaps lower test switch compartment cover; insertion of Meter securely holds upper cover in place by means of a catch Lower test switch compartment cover securely held by upper cover and a catch at bottom A removable mounting bridge is provided for fastening test switch Supplied with screw type ring Primarily used in: AB, Sask.
5 , Man., Ont., , , (CT104-SWL) Meter SocketsCT-SWL Series20 A 600 V; Transformer Rated c/w Test Switch Product Specifications Conductor range: 14-10 AWG Tunnel type connectors for both load and line sides For underground service only Lower test switch compartment cover securely held by upper cover and a out device with an enlarged pad hole ( in. dia.) Test switch included as part of these models Units are prewired from base to test switch Furnished with tamper resistant device for Meter ring Weatherproof Type 3R enclosure Approved for copper onlyCat. (in.)Weight JAWCT104-SWLF actory prewired unit with lockout device on bottom door19-1/811-13/165-7 prewired unit with lockout device on bottom door (Enmax approved) 5th Jaw in 6 o clock positionCT104-5 SWLHQH ydro-Qu bec approved 20 A current transformer Meter socket188-1/44-1 Hydro approved 20 A current transformer Meter socket19-1/811-13/165-7 JAWCT106-SWLF actory prewired unit with lockout device on bottom door19-1/811-13/165-7 approved 20 A current transformer Meter socket19-1/811-13/165-7 JAWCT113-SWLF actory prewired unit with lockout device on bottom door19-1/811-13/165-7 approved 20 A current transformer Meter socket19-1/811-13/165-7 SizeKnockout 3/4, 1 and 1-1/4 Places3-5/8 Size Knockout 1/2 Place1-5/16 Size Knockout 1/2 Place19-1/8 SizeKnockout 1/2, 3/4, 1 and 1-1/4 Places1-1/2 (R3-1V) Meter SocketsR3 Series100 A 600 V.
6 Round Aluminum Product Specifications Conductor range: 14-2 AWG Aluminum tunnel type connectors for both load and line sides Can be converted from vertical to horizontal mounting using same components Supplied with screw type ring Aluminum die cast socket Weatherproof Type 3R enclosure Primarily used in: , Northern Ont. Approved for copper onlyCat. (in.)Weight JAWR3-1V1 in. hub7-1/83-1 in. hubR3-1-5V1 in. hub - 5th jaw, standard capacity, 9 o clock positionR3-1 1/4-5V1-1/4 in. hub - 5th jaw, standard capacity, 9 o clock position2-7/8 (BA3-1 1/4V) Meter SocketsBA3 Series100 A 600 V; ShallowProduct Specifications Conductor range: 6-2 AWG Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in: All provincesNote: Supply from an underground network often requires use of stud type connector.
7 Consult your local utility. Approved for copper onlyCat. (in.)Weight JAWBA3-VOverhead, hub opening9-1/47-7/163-11 , hub opening, c/w 1 in. hubBA3-1 1/4 VOverhead, hub opening, c/w 1-1/4 in. hubBA3-TVUndergroundBA3-TCVC ombination overhead-undergroundBA33-VOverhead, twin hub openingBA33-1 VOverhead, twin hub opening c/w 1 in. hubsBA33-1 1/4 VOverhead, twin hub opening, c/w 1-1/4 in. hubsBA4-VIndoor type, on topFACTORY-INSTALLED ACCESSORIESI nclude: -INInsulated Neutral -55th jaw, standard capacity, 9 o clock position -95th jaw, full capacity, 9 o clock position1-9/16 SizeKnockout 1/2, 1 and 1-1/4 PlacesTrade SizeKnockout 1-1/4, 1 and 1-1/2 Size Knockout 1/4 (BE1-1 1/4V) Meter SocketsBE1 Series100 A 600 V; King SizeProduct Specifications Conductor range: 6-1/0 AWG Aluminum tunnel type connectors for both load and line sides For overhead, underground and combination overhead/underground Supplied with screw type ring Weatherproof Type 3R enclosure Primarily used in all provincesNote: Supply from an underground network often requires use of stud type connector.
8 Consult your local utility. Approved for copper or aluminumCat. (in.)Weight JAWBE1-VOverhead, hub opening14-5/88-1/44-3 1/4 VOverhead, hub opening, c/w 1-1/4 in. hubBE1-1 1/2 VOverhead, hub opening, c/w 1-1/2 in. hubBE1-TVUndergroundBE1-TCVC ombination overhead-undergroundBE11-V-CMOverhead, twin hub openingBE11-1 1/4 VOverhead, twin hub opening c/w 1-1/4 in. hubsFACTORY-INSTALLED ACCESSORIESI nclude: -55th jaw, standard capacity, 9 o clock position -95th jaw, full capacity, 9 o clock position -65th jaw, full capacity, 6 o clock position -INInsulated neutral -WWater heater lugsCOMBINATION AND UNDER GROUND BOTTOMOVERHEAD BOTTOM4 Size Knockout 1/4 Size Knockout 1/2 SizeKnockout 1, 1-1/4, 1-1/2 and 2 Places4-3/8 SizeKnockout 1-1/4, 1-1/2 and 2 Size Knockout 1/4 Size Knockout 1/2 SizeKnockout 1-1/4, 1-1/2 and 2 (BE6-V) Meter SocketsBE2 Series200 A (Main Lugs) 600 V.
9 Multiple Position Horizontal 100 A per PositionProduct Specifications Conductor range: Line: 6 AWG-250 kcmil, Load: 6-1/0 AWG Aluminum tunnel type connectors for both line and load sides Factory prebussed from main lugs to each position Combination overhead-underground supplied with hub opening closure plate for underground service Hubs to be ordered separately (refer to pp. D47 and D48) Supplied with screw type rings Weatherproof Type 3R enclosure Primarily used in: All provinces Approved for copper or aluminumCat. PositionDimensions (in.)Weight JAWLEFT-HAND ENTRYRIGHT-HAND ENTRYBE2-VBE2-VH2 position14-5/816-1/25-3 position24-13 position33-1 position41-7 position49-3 ACCESSORIESI nclude: -55th jaw, standard capacity, 9 o clock positionNOTE: Supply from an underground network often requires useof stud type connector.
10 Consult your local SizeKnockout 1-1/4, 1-1/2 and 2 in.(each side of the box separation)Trade SizeKnockout 1/22 Places(for each end of the bottom) 1-13/16 SizeKnockout 1-1/4, 1-1/2, 2 and 2-1/2 in.(for every box separation)1-1/16 (BEC2-V) Meter SocketsBEC Series200 A (Main Lugs) 600 V; Multiple Position 100 A per Position Stud Type Product Specifications Conductor range: Line: 1/2 in. studs supplied, Load: 6-1/0 AWG Aluminum tunnel type connectors load side; stud 1/2 in. line side For underground service only Factory prebussed from main lugs to each position Supplied with screw type rings Weatherproof Type 3R enclosure Primarily used in: , *Sask. (extended enclosure), Man., Ont., Que.* Note: Models with suffix -VA and -VAH = tunnel type connectors on line side provided instead of studs (required by Hydro).