SPECIFICATIONS. D03 Pattern Directional Control Valves Also refer to " Directional Valve Features, Selection and Operating Recommendations" ( ). CONTACT INFORMATION. USA Headquarters Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 Tel: 262-691-2222. FAX: 262-691-0312. E-mail: Power Units & Systems Dynex/Rivett Inc. 54 Nickerson Road Ashland, MA 01721 Tel: 508-881-5110. FAX: 508-881-6849. E-mail: European Sales Dynex/Rivett Inc. Unit C5 Steel Close, Little End Road, Eaton Socon, Huntingdon, Cambs. PE19 8TT United Kingdom Tel: +44 (0) 1480 213980. FAX: +44 (0) 1480 405662. E-mail: For more information visit our web site: BROCHURE NOTES: Consult the Dynex sales department for a review of any application which requires operating above the rated flows or pressures, or higher than normal operating temperatures.

D03 PATTERN 2 Compact Valves Control Flow to 15 U.S.gpm (57 L/min) High performance D03 valves are rated for 8 U.S. gpm (30 L/min) nominal and 15 U.S. gpm (57 L/min)

Tags:

  Patterns, D03 pattern

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of D03 Pattern Directional Control Valves - macmhydraulic.com

1 SPECIFICATIONS. D03 Pattern Directional Control Valves Also refer to " Directional Valve Features, Selection and Operating Recommendations" ( ). CONTACT INFORMATION. USA Headquarters Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 Tel: 262-691-2222. FAX: 262-691-0312. E-mail: Power Units & Systems Dynex/Rivett Inc. 54 Nickerson Road Ashland, MA 01721 Tel: 508-881-5110. FAX: 508-881-6849. E-mail: European Sales Dynex/Rivett Inc. Unit C5 Steel Close, Little End Road, Eaton Socon, Huntingdon, Cambs. PE19 8TT United Kingdom Tel: +44 (0) 1480 213980. FAX: +44 (0) 1480 405662. E-mail: For more information visit our web site: BROCHURE NOTES: Consult the Dynex sales department for a review of any application which requires operating above the rated flows or pressures, or higher than normal operating temperatures.

2 Specifications shown were in effect when published. Since errors or omissions are possible, contact your sales representative for the most current specifications before ordering. Dynex reserves the right to discontinue or change designs at any time without incurring any obligation. DYNEX High Pressure Hydraulics Copyright Dynex/Rivett Inc. Bulletin dynexvesd03specs-1101. D03 Pattern . Compact Valves Control Flow to 15 gpm (57 L/min). High performance D03 Valves are rated for 8 gpm (30 L/min). nominal and 15 gpm (57 L/min). maximum flow, at pressures to 5000 psi (350 bar). This high pressure and high flow capability provides great efficiency in a very compact size.

3 6500 Series HIGH EFFICIENCY OPERATION Explosion Proof 6500 Series Double Solenoid Large internal flow passages, with uniform flow areas throughout the body coring, provide exceptional efficiency. Typical loop pressure drop (open center spool) is a low 98 psi at 8 gpm (7 bar at 30 L/min) nominal 6800 Series 6900 Series flow ( P loop = P A + B T). Hydraulic Piloted Air Piloted SMOOTH, RELIABLE SHIFTING. A four-land spool design assures exceptionally smooth spool travel. Additional outboard lands provide greater support, eliminating spool imbalance. RELIABLE VALVE SEALING. HIGH PRESSURE TANK PORT. Balancing grooves provide precise Tapered o-ring counterbores reduce centering, reducing silt buildup and High pressure tank port capability provides the highest T port rating leakage, by assuring seal retention potential spool sticking.

4 In high flow or rapid cycling available. This option ( HPT ) is ideal for higher pressure series circuits. operation. High-torque mounting prevents weepage between sections when using sandwich accessory Valves . 2000 3000. DC. PRESSURE VALVE. AC PORT BODY. 1000 4000. 0 5000 MOUNTING SURFACE. Close tolerances assure accurate PSI. O-RING. land sequencing and low leakage. HIGH PRESSURE. Spools are interchangeable to meet SOLENOID TUBES. changing requirements. Potential leakage is reduced by tapered High pressure solenoid tubes (HPT option) o-ring counterbores which assure seal LOW POWER REQUIREMENTS make the D03 ideal for use in higher retention in high flow applications.

5 On solenoid models, efficient low pressure series circuits. power requirements reduce energy consumption. Holding power requirements are only 20 Watts for 115 Volt or 28 Watts for 12 or 24 Volt solenoids. 2. D03 Pattern . SPECIFICATIONS ELECTRICAL DATA. General For a description of spools,operator Input Inrush Holding Holding Coil Frequency Solenoid Code Voltage Current Current Power Resistance functions, electrical options and (Hz). (Volts) (Amps) (Amps) (Watts) (Ohms 10%). operating recommendations, refer to 24/DF 24 50 27 (Dual Frequency) 24 60 22 Mounting Subplate, D03 (CETOP 3) 115/DF 110 50 .47 20 Pattern (Dual Frequency) 115 60 .40 20 Operator Options 230/DF 220 50.

6 86 .22 20 (Dual Frequency) 230 60 .80 .18 20 6100 Series:Manual Lever;. 6500 Series: Direct Solenoid; 460/DF 440 50 .40 .13 23 6800 Series: Hydraulic Piloted; (Dual Frequency) 460 60 .41 .10 21 6900 Series: Air Piloted 12 VDC 12 28 Rated Flow 24 VDC 24 28 Nominal: 8 gpm (30 L/min); 12 VDC EPW 12 33 Maximum: 15 gpm (57 L/min). 24 VDC EPW 24 33 Maximum flow for models using a Type 011 spool is 9 gpm 110/50 EPW 110 50 .54 23 (34 L/min) for solenoid models and 115/60 EPW 115 60 .50 23 10 gpm (38 L/min) for air and Ordering Codes shown are for standard wire leads with wiring box. Plug-In-Terminal solenoids hydraulic pilot operated model. See (Hirschmann GDM 209) are also available; see Typical Model Code on page 17.

7 Flow capacity curves on page 4. Rated Pressure 5000 psi (350 bar). Tank Port Pressure (Maximum). Standard: Electrical Connections UL Classification: 1500 psi (105 bar); Standard Wiring Box with leads; Class I, Group C,D;. High Pressure Option ( HPT ): Optional Terminal Strip, Cable Grip Class II, Group E,F,G. , 2300 psi (160 bar); or Pin Connector ( CSA/UL Recognized ( C Option). , 3000 psi (210 bar) standard ; Solenoid coils are printed with standard B93,55M-1981); the symbol: Response Time (Full Stroke). Optional Plug-In-Terminal Solenoids Solenoid Energized: fit DIN Connector Standard 4365 C.. (CSA and UL Recognized). , 12 ms; , 20 ms (Hirschmann GDM 209) Available with 115/DF coils only.

8 For Spring Returned: Explosion Proof Option ( EPW ) other voltages, contact the Dynex , 15 ms; , 20 ms Solenoids with special enclosures sales department. Solenoids are approved by UL and CSA for use Models are available with or in hazardous locations. Available with solenoids. or solenoids. The table above shows electrical specifications for these Valves . MANUAL OPERATED MODELS. A12 or B12. Lever operated models offer handle position flexibility with four positions on either port A end or port B end A9. or of valve. B9. A3. In-the-field changes are easy, by or B3. removing the bracket assembly and rotating the handle to the desired position. A6 or B6.

9 To specify position, see Typical Handle Position Viewed from Model Code on page 8 and refer to Port A or Port B End of Valve the drawing at right. 3. D03 Pattern . Typical Valve FLOW CAPACITY. Performance BAR PSI. SOLENOID MODELS 350 5000 A. 300 BC H J K. The flow capacity curves show typical PRESSURE. 4000. performance for each spool type. The 250 DE F G. 200 3000. letters in the Flow Curve Reference . table identify the appropriate curve. 150 2000. 100. 1000. 50. LEVER OPERATED MODELS 0. GPM 2 4 6 8 10 12 14 16. Most manual models are rated for 15 gpm (57 L/min) maximum. L/MIN. 10 20 30 40 50 60. The exception is model 613011-D03 FLOW. which is rated for 13 gpm (49 L/min) maximum.

10 This model has a Code 3 internal operator (two position, detented operation) with Type 011 spool (tandem center). FLOW CURVE REFERENCE. Solenoid Spool Type PILOT OPERATED MODELS Type 0 1 3 4 011 2 2R 32 32R 36 03. The maximum flow for pilot operated A A H A C E E J J B B. models is dependent on pilot pressure. and EPW A A A A D K K F F G A. Generally, the maximum flow for most pilot operated models is 15 gpm (57 L/min). When using a Type 011. spool (tandem center, open cross- over), the maximum flow rating is MINIMUM PILOT PRESSURE. 10 gpm (38 L/min). Minimum Pilot Pressure Pilot Pressure At: The table shows the minimum Spool 5 gpm 8 gpm 15 gpm Series pressure required to shift the spool, Type (19 L/min) (30 L/min) (57 L/min).